3. Installation space
3-1. Models: AOU9RLS3H, AOU12RLS3H, and AOU15RLS3H
¢
Space requirement
Provide sufficient installation space for product safety.
Single outdoor unit installation
•
When the upper space is open:
Unit: in (mm)
When there are obstacles at the rear only.
When there are obstacles at the rear and
sides.
4 (100) or more
10 (250) or more
4 (100) or more
4 (100) or more
When there are obstacles at the front only.
When there are obstacles at the front and
rear.
24 (600) or more
24 (600) or more
4 (100) or more
•
When there is an obstruction in the upper space:
Unit: in (mm)
When there are obstacles at the rear and
above.
When there are obstacles at the rear, sides,
and above.
4 (100) or more
Max. 7 (200)
24 (600)
or more
24 (600)
or more
4 (100) or more
10 (250) or more
4 (100) or more
Max. 7 (200)
- 42 -