ERROR STATUS OUTPUT
An air conditioner error status signal can be output.
Circuit diagram example
z
* Make the distance from the PC board to the connected unit within 10 m.
Relay spec.: Max. DC 24 V, 10 mA to less than 500 mA.
Field supply
Optional parts
Ex.) Display
Indoor unit
control PC board
Communication kit
Connected unit
Ex.) Relay unit
1
2
Signal
Relay
power
supply
V
Connector
10 m*
DC 24 V
ON
OFF
Error
Normal
Error status
Output signal
Parts (Optional)
z
Parts name
Model name
External connect kit
UTY-XWZXZ5
Communication kit
UTY-TWBXF1
* For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire
(UTY-XWZXZ5).
Wire (External output) : UTY-XWZXZ5