5

Turn on the Power

1

Turn on the circuit breaker.

2

Set the POWER switch (Fig. 2 

2

) to ON.

Load Batteries (R03/LR03 

×××××

 2)

1

Press and slide the battery compartment lid on the re-
verse side to open it.

Slide in the direction of the arrow while pressing the 

 mark.

2

Insert batteries.

Be sure to align the battery polarities (

) correctly.

3

Close the battery compartment lid.

Set the Current time

1

Press the TIME ADJUST button (Fig. 7 

Q

).

Use the tip of a ball-point pen or other small object to press the button.

2

Use the 

 SET TIME buttons (Fig. 6 

J

) to adjust

the clock to the current time.

button:

Press to advance the time.

button:

Press to reverse the time.

(Each time the buttons are pressed, the time will be advanced/reversed in
one-minute increments; hold the buttons depressed to change the time
quickly in ten-minute increments.)

3

Press the TIME ADJUST button again.

This completes the time setting and starts the clock.

To Use the Remote Control Unit

The remote control unit must be pointed at signal receiver (Fig. 1 

4

) to operate

correctly.

Operating range: About 7 meters.

When a signal is properly received by the air conditioner, a beeping sound will
be heard.

If no beep is heard, press the remote control unit button again.

Remote Control Unit Holder

PREPARATION

 CAUTION!

Take care to prevent infants from
accidentally swallowing batteries.

When not using the remote control unit
for an extended period, remove the
batteries to avoid possible leakage and
damage to the unit.

If leaking battery fluid comes in contact
with your skin, eyes, or mouth, immedi-
ately wash with copious amounts of
water, and consult your physician.

Dead batteries should be removed
quickly and disposed of properly, either
by placing in a public battery collection
receptacle, or by returning to appropri-
ate authority.

Do not attempt to recharge dry batteries.

Never mix new and used batteries, or
batteries of different types.
Batteries should last about one year
under normal use. If the remote control
unit’s operating range becomes appre-
ciably reduced, replace the batteries and
press the ACL button with the tip of a
ballpoint pen or other small object.

3

To remove the Remote
Control Unit (when use at
hand).

1

Mount the Holder.

2

Set the Remote Control
Unit.

Screws

Insert

Press in

Slide up

Pull out

Содержание AOT30QMAM4

Страница 1: ...ATION MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P N9372250013 HEAT COOL MODEL REVERSE CYCLE INDOOR UNIT AST9QM AST12QM OUTDOOR UNIT AOT30QMAM4 OPERATING MANUAL ROOM AIR CONDITIONER MULTI SPLIT TYPE 4 ROOMS ...

Страница 2: ... to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants...

Страница 3: ...T The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s INTAKE GRILLE can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resis...

Страница 4: ...2 Fig 3 Fig 4 Fig 8 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actual operation however the display will only show those indicators appropriate to the current op eration Fig 7 ...

Страница 5: ...emote Control Unit Display Fig 8 U Transmit Indicator V Clock Display W Operating Mode Display X Timer Mode Display Y Fan Speed Display Z Temperature Set Display Timer Set Indicator Temperature Set Indicator Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 POWER Switch 3 MANUAL AUTO button 4 Remote Control Signal Receiver 5 Indicator Lamps Fig 3 6 OPERATION Indicator Lamp red Lights when unit i...

Страница 6: ...rating range About 7 meters When a signal is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the remote control unit button again Remote Control Unit Holder PREPARATION CAUTION Take care to prevent infants from accidentally swallowing batteries When not using the remote control unit for an extended period remove the batteries to avoid possible leaka...

Страница 7: ...Fan Speed Press the FAN CONTROL button Fig 6 M Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low C...

Страница 8: ...selected fan set ting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic De frosting operation the OPERATION indicator lamp red wi...

Страница 9: ...mer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Control Unit s display OFF ON or OFF ON One example of PROGRAM timer use m...

Страница 10: ...ing Timer Operation Press the START STOP button About the SLEEP timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat set ting in accordance with the time setting When the set time has elapsed the air conditioner completely stops During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered 1...

Страница 11: ...rom the air conditioner During the Cooling and Dry modes if the Air Flow Direction Louvers are left in the range 5 to 7 for more than 30 minutes they will au tomatically return to position 4 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLO...

Страница 12: ...ration is con tinued at the lowest downward range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet The SWING operation may stop temporarily when the air conditioner s fan is not operating or when operating at very low speeds MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event ...

Страница 13: ...rned properly to their holes in the panel 2 Close the intake grille For purposes of example the illustration shows the unit without intake grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before rein stalling If ...

Страница 14: ...d replacement air clean ing filters type APS 02F and install them 1 Open the intake grille and remove the air filters 2 Replace them by two new air cleaning filters 1 Remove the old air cleaning filters in reverse order of their installation 2 Install in the same way as for installation of the air cleaning filter set 3 Install the two air filters and close the intake grille In regard to the Air cl...

Страница 15: ...rom the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may sto...

Страница 16: ...ly stop operation turn off the circuit breaker and consult authorized service personnel OPERATING TIPS Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we...

Страница 17: ... of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily disconnect the Power Supply Plug reconnect it and then use the remote control unit to resume operation The air conditioner power has been interrupted by a power failure The air conditioner will then restart automatically in its pre...

Страница 18: ...rating modes If the indoor unit is instructed to do an operating mode that it cannot perform the OPERATION indicator lamp red on the indoor unit will flash 1 second on 1 second off and the unit will go into the standby mode Heating mode and cooling mode or dry mode Heating mode and fan mode Operation can be done in the following different operat ing modes Cooling mode and dry mode Cooling mode and...

Страница 19: ...W Starting Current A Noise Level dB A Dimensions mm Net Weight kg Compressor Type Motor output kW Piping Connections Type Unit A Unit B Unit C Unit D Maximum Pipe Length Each Unit m Maximum Pipe Length Total m Maximum Pipe Height Different m Refrigerant Wiring Connection Power Supply Indoor to Outdoor Operating Temperature Range C AOT30QMAM4 4 27 000 48 000 8 0 14 0 kW Cooling Heating 240 220 V 50...

Отзывы: