TROUBLESHOOTING

Symptom

Doesn’t operate at all:

Poor Cooling performance:

The unit operates
differently from the Remote
Control Unit’s setting:

See Page

8 - 9

6

5

CHECK ONCE

MORE

Items to check

Is the Power Supply Plug disconnected its outlet?

Has there been a power failure?

Has a fuse blown out, or a circuit breaker been tripped?

Is the timer operating?

Is the air filter dirty?

Air the air conditioner’s intake grille or outlet port blocked?

Did you adjust the room temperature settings (thermostat) cor-
rectly?

Is there a window or door open?

In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)

In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?

Is the unit set for SUPER QUIET operation?

Are the Remote Control Unit’s batteries dead?

Are the Remote Control Unit’s batteries loaded properly?

OPERATING TIPS

Microcomputer-controlled Automatic Defrosting

When using the Heating mode under conditions of low
outdoor temperature and high humidity, frost may form
on the outdoor unit, resulting in reduced operating per-
formance.

In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Auto-
matic Defrosting function. If frost forms, the air condi-
tioner will temporarily stop, and the defrosting circuit will
operate briefly (for about 7-15 minutes).

During Automatic Defrosting operation, the OPERATION
indicator lamp (red) will flash.

Heating Performance

This air conditioner operates on the heat-pump princi-
ple, absorbing heat from outdoor air and transferring that
heat indoors. As a result, the operating performance is
reduced as outdoor air temperature drops. If you feel that
insufficient heating performance is being produced, we
recommend you use this air conditioner in conjunction
with another kind of heating appliance.

Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.

If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator Lamp (Fig. 3 

6

)

flashes, immediately stop operation, disconnect the Power Supply Plug (Fig. 1 

C

), and consult authorized service personnel.

Operation and Performance

AUTO Restart

In Event of Power Interruption

The air conditioner power has been interrupted by a power
failure. The air conditioner will then restart automatically
in its previous mode when the power is restored.

Operated by setting before the power failure.

If a power failure occurs during TIMER operation, the timer
will be reset and the unit will begin (or stop) operation at the
new time setting. In the event that this (kind of timer fault
occurs the TIMER Indicator Lamp will flash (see Page. 4)).

Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the
air conditioner to malfunction. In this event, temporarily
disconnect the Power Supply Plug, reconnect it, and then
use the Remote Control Unit to resume operation.

14

Содержание AOT12RSJC

Страница 1: ...L REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this p...

Страница 2: ...purpose tools and specified cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner...

Страница 3: ... con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easi...

Страница 4: ... 9 0 3 1 4 5 6 8 2 7 OPERATION TIMER SWING ª ºŸ _ Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 7 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig 6 3 ...

Страница 5: ...on Q CANCEL TIMER button R FAN CONTROL button S START STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switc...

Страница 6: ... of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the bat...

Страница 7: ... the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the tempera ture of the...

Страница 8: ...at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to...

Страница 9: ...time while the ONTIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ONTimer mark will be shown on the remote control unit s dis play The Indoor UnitTimer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANCEL TIMER button ...

Страница 10: ...es the thermostat set ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapsed at which ti...

Страница 11: ...vers are left in the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 T Each time the button is pressed the air direction range w...

Страница 12: ... range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop op...

Страница 13: ...ir holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is allowed to acc...

Страница 14: ...r resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop ...

Страница 15: ...ndicator lamp red will flash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind o...

Страница 16: ...o prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humi...

Отзывы: