background image

Cleaning the Intake Grille

1. Remove the Intake Grille.

1

Place your fingers at both lower ends of the grille
panel, and lift forward; if the grille seems to catch
partway through its movement, continue lifting up-
ward to remove.

2

Pull past the intermediate catch and open the Intake
Grill wide so that it become horizontal.

2. Clean with water.

Remove dust with a vacuum cleaner; wipe the unit with
warm water, then dry with a clean, soft cloth.

3. Replace the Intake Grille.

1

Pull the knobs all the way.

2

Hold the grille horizontal and set the left and right
mounting shafts into the bearings at the top of the
panel.

1

2

2

1

2

CLEANING AND CARE

 CAUTION!

Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord.

Be sure the Intake Grille  (Fig. 1 

8

) is installed securely.

When removing and replacing the air filters, be sure not to touch the heat exchanger, as personal
injury may result.

Cleaning the Air Filter

1. Open the Intake Grille, and remove the air

filter.

Lift up the air filter’s handle, disconnect the two lower
tabs, and pull out.

2. Remove dust with a vacuum cleaner or

by washing.

After washing, allow to dry thoroughly in a shaded place.

3. Replace the Air Filter and close the Intake

Grille.

1

Align the sides of the Air Filter with the panel, and
push in fully, making sure the two lower tabs are re-
turned properly to their holes in the panel.

2

Close the Intake Grille.

(For purposes of example, the illustration shows the unit
without Intake Grille installed.)

Dust can be cleaned from the Air Filter either with a
vacuum cleaner, or by washing the filter in a solution of
mild detergent and warm water. If you wash the filter, be
sure to allow it to dry thoroughly in a shady place before
reinstalling.

If dirt is allowed to accumulate on the Air Filter, air flow
will be reduced, lowering operating efficiency and in-
creasing noise.

During periods of normal use, the Air Filters should be
cleaned every two weeks.

Intake Grille

Air filter handle

Hooks (two places)

Intake Grille

Hooks (two places)

When using the optional Air Cleaning Filter

Install the optional Air Cleaning Filter set (APS-03B) as instructed (installation instructions are furnished with the Air Clean-
ing Filter set).

When used for extended periods, the unit may accumulate dirt inside, reducing its performance. We recommend that the
unit be inspected regularly, in addition to your own cleaning and care. For more information, consult authorized service
personnel.

When cleaning the unit’s body, do not use water hotter than 40 °C, harsh abrasive cleansers, or volatile agents like
benzene or thinner.

Do not expose the unit body to liquid insecticides or hairsprays.

When shutting down the unit for one month or more, first allow the fan mode to operate continuously for about one-half
day to allow internal parts to dry thoroughly.

Intake Grille

Mounting

shaft

Knob

Intake Grille

Mounting shaft

Bearing

Knob

Mounting

shaft

Knob

12

Содержание AOT12RSJC

Страница 1: ...L REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE R410A REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A and Polyol Ester oil THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED BY QUALIFIED PERSONNEL Refer to Commonwealth State Territory and local legislation regulations codes installation operation manuals before the installation maintenance and or service of this p...

Страница 2: ...purpose tools and specified cord are required Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner...

Страница 3: ... con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE INTAKE GRILLE The indoor unit s Intake Grille can be removed for easy clean ing and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easi...

Страница 4: ... 9 0 3 1 4 5 6 8 2 7 OPERATION TIMER SWING ª ºŸ _ Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 7 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig 6 3 ...

Страница 5: ...on Q CANCEL TIMER button R FAN CONTROL button S START STOP button T AIR FLOW DIRECTION button U SWING LOUVER button V ACL button W TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switc...

Страница 6: ... of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 C to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid on the re verse side to open it Slide in the direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the bat...

Страница 7: ... the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Fig 6 R Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the tempera ture of the...

Страница 8: ...at very low fan speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to...

Страница 9: ...time while the ONTIMER mark on the remote control unit s display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 P to select ON TIMER opera tion The ONTimer mark will be shown on the remote control unit s dis play The Indoor UnitTimer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANCEL TIMER button ...

Страница 10: ...es the thermostat set ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapsed at which ti...

Страница 11: ...vers are left in the heat ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 T Each time the button is pressed the air direction range w...

Страница 12: ... range for more than 30 minutes the unit will automatically switch the swing range to the horizontal flow range to prevent the condensation of moisture on the outlet MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Control Unit is lost or otherwise unavailable How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 2 on the main unit control panel To stop op...

Страница 13: ...ir holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the Air Filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in a shady place before reinstalling If dirt is allowed to acc...

Страница 14: ...r resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop ...

Страница 15: ...ndicator lamp red will flash Heating Performance This air conditioner operates on the heat pump princi ple absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind o...

Страница 16: ...o prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humi...

Отзывы: