background image

En-2

FEATURES AND FUNCTIONS

INVERTER

At the start of operation, a large power is used to bring the 
room quickly to the desired temperature. Afterwards, the unit 
automatically switches to a low power setting for economic and 
comfortable operation.

COIL DRY OPERATION

The Indoor unit can be dried by pressing the COIL DRY button 
on the Remote Controller so as to avoid going moldy and restrain 
the breed of bacterium. 

AUTO CHANGEOVER

The operation mode (cooling, dry, heating) is switched automati-
cally to maintain the set temperature, and the temperature is kept 
constant at all times.

PROGRAM TIMER

The program timer allows you to integrate OFF timer and ON 
timer operations in a single sequence. The sequence can involve 
one transition from OFF timer to ON timer, or from ON timer to 
OFF timer, within a twenty-four hour period.

SLEEP TIMER

When the SLEEP button is pressed during Heating mode, the air 
conditioner’s thermostat setting is gradually lowered during the 
period of operation; during cooling mode, the thermostat setting 
is gradually raised during the period of operation. When the set 
time is reached, the unit automatically turns off.

WIRELESS REMOTE CONTROLLER

The Wireless Remote Controller allows convenient control of air 
conditioner operation.

HORIZONTAL AIRFLOW: COOLING/
DOWNWARD AIRFLOW: HEATING

For cooling, use horizontal air

fl

 ow so the cool air does not blow 

directly on the occupants in the room. For heating, use down-
ward air

fl

 ow to send powerful, warm air to the 

fl

 oor and create 

a comfortable environment.

OMNI-DIRECTIONAL AIR FLOW
(SWING OPERATION)

Three-dimensional control over air direction swing is possible 
through dual use of both an UP/DOWN air direction swing and 
RIGHT/LEFT air direction swing. Since UP/DOWN air direction 

fl

 aps operate automatically according to the operating mode of 

the unit, it is possible to set air direction based on the operating 
mode.

REMOVABLE OPEN PANEL

The indoor unit’s Open Panel can be removed for easy cleaning 
and maintenance.

MILDEW-RESISTANT FILTER

The AIR FILTER has been treated to resist mildew growth, thus 
allowing cleaner use and easier care.

SUPER QUIET OPERATION

When the FAN CONTROL button is used to select QUIET, the 
unit begins super-quiet operation; the indoor unit’s air

fl

 ow  is 

reduced to produce quieter operation.

POLYPHENOL CATECHIN AIR CLEANING FILTER

The polyphenol catechin air cleaning 

fi

 lter uses static electricity 

to clean the air of 

fi

 ne particles and dust such as tobacco smoke 

and plant pollen that are too small to see.
The 

fi

 lter contains catechin, which is highly effective against 

various bacteria by suppressing the growth of the bacteria ad-
sorbed by the 

fi

 lter.

Note that when the air cleaning 

fi

 lter is installed, the amount 

of air produced decreases, causing a slight decrease in the air 
conditioner’s performance.

NEGATIVE AIR IONS DEODORIZING FILTER

It comprises pottery super micro particles, which can produce 
negative air ions having the effect of deodorizing and can absorb 
and remit the peculiar smell at home. 

The optional wired remote controller (model No. : UTB-YUD) can be used.
When you use remote controller, there are following different points as compared with using wireless remote controller.
[The additional functions for wired remote controller]

● 

Weekly timer   

● 

Temperature set back timer

[The restricted functions for wired remote controller]

● 

ECONOMY    

● 

MAINTENANCE    

● 

THERMO SENSOR

And you can't use both wired remote controller and wireless remote controller simultaneously.
(Only one kind can be selected)

WIRED REMOTE CONTROLLER (OPTION)

9315345318-03_OM.indb   2

9315345318-03_OM.indb   2

2/26/2013   11:12:54 AM

2/26/2013   11:12:54 AM

Содержание AOBR24LFL

Страница 1: ...YCLE KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MANUAL DE FUNCIONANENTO PARA REFERÊNCIA FUTURA FUJITSU GENERAL LIMITED P N9315345318 03 OPERATING MANUAL MANUAL DE FUNCIONAMIENTO MANUAL DE INSTRUÇÕES 9315345318 03_OM indb 1 9315345318 03_OM indb 1 2 26 2013 11 12 37 AM 2 26 2013 11 12 37 AM ...

Страница 2: ... water drained from the air conditioner Do not use in applications involving the storage of foods plants or animals precision equipment or art works Connection valves become hot during Heating handle with care Do not apply any heavy pressure to radiator fins Operate only with air filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at le...

Страница 3: ...on swing Since UP DOWN air direction flaps operate automatically according to the operating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL The indoor unit s Open Panel can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER ...

Страница 4: ... Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 7 To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current operation Fig 6 24L 30L 9315345318 03_OM indb 3 9315345318 03_OM indb 3 2 26 2013 11 12 54 AM 2 26 2013 11 12 54 AM ...

Страница 5: ...mperature SET Display b COIL DRY Display c SLEEP Display d SWING Display NAME OF PARTS Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling...

Страница 6: ...l is properly received by the air conditioner a beeping sound will be heard If no beep is heard press the Remote Controller button again Remote Controller Holder PREPARATION CAUTION Take care to prevent infants from acciden tally swallowing batteries When not using the Remote Controller for an extended period remove the batteries to avoid possible leakage and damage to the unit If leaking battery ...

Страница 7: ...n Speed Press the FAN CONTROL button Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Coo...

Страница 8: ...selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indicator Lamp Fig 3 5 ...

Страница 9: ...The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Controller s Display OFF ON or OFF ON One example of Program timer use might be to have the air conditioner automatically s...

Страница 10: ...EEP timer is set the thermostat setting is automati cally raised 1 C every sixty minutes When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the thermostat setting is automatically lowered ...

Страница 11: ...ith infants children elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Cooling Dry modes 4 5 6 During Heating mode The Remo...

Страница 12: ... it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direction Airflow direction is 1 4 for cooling dry With the upper airf...

Страница 13: ...dle disconnect the two lower tabs and pull out Air filter handle Hooks two places 2 Remove dust with a vacuum cleaner or by washing After washing allow to dry thoroughly in a shaded place CAUTION To avoid excessive wear of the part and components or malfunctioning of the air conditioning the user consumer shall perform preventive maintenance through an accredited technical assistance periodically ...

Страница 14: ...aning filter set 2 Engage the latch at both ends of the filter with the two hooks at the rear of the air cleaning filter frame Take care that the air cleaning filter does not project beyond the frame 3 Engage the four fixing locations at the top and bottom of the air cleaning filter frame with the hooks of the air filter 3 Install the two Air filters and close the Intake Grille When air cleaning f...

Страница 15: ...emitted During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation 15 In regard to the Air Cleani...

Страница 16: ... a power failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating 8 9 Poor Cooling performance Is the Air Filter dirty Air the air conditioner s intake grille or outlet port blocked Did you adjust the room temperature settings thermostat correctly Is there a window or door open In the case of Cooling operation is a window allowing bright sunlight to enter Close the cur...

Страница 17: ...00 27 000 POWER INPUT kW 2 16 2 44 CURRENT MAX A 9 9 13 5 11 2 17 0 ENERGY EFFICIENCY RATIO kW kW 3 26 3 24 AIRFLOW INDOOR UNIT m3 h 1 100 1 100 OUTDOOR UNIT m3 h 2 470 3 600 HEATING CAPACITY kW 7 91 9 08 BTU h 27 000 31 000 POWER INPUT kW 2 31 2 77 CURRENT MAX A 10 6 18 5 12 7 19 0 ENERGY EFFICIENCY RATIO kW kW 3 42 3 28 AIRFLOW INDOOR UNIT m3 h 1 120 1 150 OUTDOOR UNIT m3 h 2 570 3 600 MAX PRESS...

Страница 18: ...9315345318 03_OM indb 17 9315345318 03_OM indb 17 2 26 2013 11 13 03 AM 2 26 2013 11 13 03 AM ...

Страница 19: ...9315345318 03_OM indb 18 9315345318 03_OM indb 18 2 26 2013 11 13 03 AM 2 26 2013 11 13 03 AM ...

Страница 20: ...9315345318 03_OM indb 2 9315345318 03_OM indb 2 2 26 2013 11 12 54 AM 2 26 2013 11 12 54 AM ...

Отзывы: