En-16
OPERATING TIPS
Temperature and Humidity Range
Cooling Mode
Dry Mode
Heating Mode
Outdoor temperature
About -10 to 46 °C
About -10 to 46 °C
About –15 to 24 °C
Indoor temperature
About 18 to 32 °C
About 18 to 32 °C
About 30 °C or less
●
If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may operate to
prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than
those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
●
Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwellings.
●
If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip
onto the
fl
oor or other objects underneath. (About 80% or more).
●
If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the
outdoor unit may stop operation for certain period of time.
SPECIFICATIONS
MODEL
INDOOR UNIT
ASBA24LFC
ASBA30LFC
OUTDOOR UNIT
AOBR24LFL
AOBR30LFT
TYPE
HEAT & COOL SPLIT TYPE (REVERSE CYCLE)
POWER
220 V ~ 60 Hz
COOLING
CAPACITY
[kW]
7.03
7.91
[BTU/h]
24,000
27,000
POWER INPUT
[kW]
2.16
2.44
CURRENT (MAX.)
[A]
9.9 (13.5)
11.2 (17.0)
ENERGY EFFICIENCY RATIO
[kW/kW]
3.26
3.24
AIRFLOW
INDOOR UNIT
[m
3
/h]
1,100
1,100
OUTDOOR UNIT [m
3
/h]
2,470
3,600
HEATING
CAPACITY
[kW]
7.91
9.08
[BTU/h]
27,000
31,000
POWER INPUT
[kW]
2.31
2.77
CURRENT (MAX.)
[A]
10.6 (18.5)
12.7 (19.0)
ENERGY EFFICIENCY RATIO
[kW/kW]
3.42
3.28
AIRFLOW
INDOOR UNIT
[m
3
/h]
1,120
1,150
OUTDOOR UNIT [m
3
/h]
2,570
3,600
MAX. PRESSURE
[MPa]
4.12
4.12
REFRIGERANT (R410A)
[kg]
1.65
2.10
DIMENSIONS & WEIGHT (NET)
INDOOR UNIT
HEIGHT
[mm]
320
WIDTH
[mm]
998
DEPTH
[mm]
228
WEIGHT
[kg]
14
OUTDOOR UNIT
HEIGHT
[mm]
578
830
WIDTH
[mm]
790
900
DEPTH
[mm]
315
330
WEIGHT
[kg]
43
61
AUTO Restart
In Event of Power Interruption
●
The air conditioner power has been interrupted by a power
failure. The air conditioner will then restart automatically in
its previous mode when the power is restored.
●
Operated by setting before the power failure.
●
If a power failure occurs during TIMER operation, the timer will
be reset and the unit will begin (or stop) operation at the new
time setting. In the event that this kind of timer fault occurs the
TIMER Indicator Lamp will
fl
ash (see Page. 4).
●
Use of other electrical appliances (electric shaver, etc.) or
nearby use of a wireless radio transmitter may cause the air
conditioner to malfunction. In this event, temporarily discon-
nect the Power Supply Plug, reconnect it, and then use the
Remote Controller to resume operation.
9315345318-03_OM.indb 16
9315345318-03_OM.indb 16
2/26/2013 11:12:57 AM
2/26/2013 11:12:57 AM
Содержание AOBR24LFL
Страница 18: ...9315345318 03_OM indb 17 9315345318 03_OM indb 17 2 26 2013 11 13 03 AM 2 26 2013 11 13 03 AM ...
Страница 19: ...9315345318 03_OM indb 18 9315345318 03_OM indb 18 2 26 2013 11 13 03 AM 2 26 2013 11 13 03 AM ...
Страница 20: ...9315345318 03_OM indb 2 9315345318 03_OM indb 2 2 26 2013 11 12 54 AM 2 26 2013 11 12 54 AM ...