WIRED REMOTE CONTROLLER
12-3.
SWITCH POSITION
DIP SWITCH 1 SETTING
DIP Switch 1
SW1
Forbidden*
SW2 Dual remote controller setting
SW3
Forbidden*
SW4
Forbidden*
SW5
Forbidden*
SW6 Memory backup setting
*Switches are fixed at OFF.
1. Dual remote controller setting
Set the remote controller on SW2 according to the following table.
2. Memory backup setting
Set to ON to use batteries for the memory backup. If batteries are not used, all of the settings
stored in memory will be deleted if there is a power failure.
ON
ON
OFF
1
2
3
4
5
6
Front case (back side)
DIP Switch 2
(All switches fixed at OFF)
DIP Switch 1
(
u
Factory setting)
Number
of remote
controller
Primary unit
Secondary unit
SW2
SW2
u
1 (Normal)
OFF
―
2 (Dual)
OFF
ON
(
u
Factory setting)
SW6
Memory backup
u
OFF
Invalidity
ON
Validity