EXTERNAL OUTPUT
11-2.
OPERATION STATUS OUTPUT
An air conditioner operation status signal can be output.
Circuit diagram example
z
* Make the distance from the PC board to the connected unit within 10m.
Relay spec. : Max.24VDC, 10mA to less than 500mA.
Field supply
Optional parts
Ex.)Display
Indoor unit
control PC board Communication kit
Connected unit
Ex.)Relay unit
1
2
Signal
Relay
power
supply
V
Connector
*10 m
24V DC
ON
OFF
Operation
Stop
Indoor unit
Output signal
Parts (Optional)
z
Parts name
Model name
External connect kit
UTY-XWZXZ5
Communication kit
UTY-TWBXF
* For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire
(UTY-XWZXZ5).
Содержание AO G09LTCN Series
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LTCB AS G12LTCB AS G14LTCB DTR_AS057E_03 2013 01 10 ...
Страница 12: ... 01 09 WALL MOUNTED TYPE AS G09 14LT WALL MOUNTED TYPE AS G09 14LT INSTALLATION PLACE Unit mm ...
Страница 24: ... 01 21 WALL MOUNTED TYPE AS G09 14LT WALL MOUNTED TYPE AS G09 14LT SOUND LEVEL CHECK POINT 88888 ...
Страница 36: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LTCN AO G12LTCN AO G14LTCN DTR_AO092E_02 2013 01 10 ...
Страница 43: ... 02 06 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT WIRING DIAGRAMS 444 MODEL AO G09LTCN AO G12LTCN ...
Страница 44: ... 02 07 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT MODEL AO G14LTCN ...
Страница 52: ... 02 15 OUTDOOR UNIT AO G09 14LT OUTDOOR UNIT AO G09 14LT SOUND LEVEL CHECK POINT 88888 ...