- (01 - 25) -
W
AL
L M
OU
NT
ED T
YP
E
AS
G
09
-1
2LT
W
AL
L M
OU
NT
ED T
YP
E
AS
G
09
-1
2LT
4) Auto restart
Enable or disable automatic system restart after a power outage.
(
... Factory setting)
Setting description
Function number
Setting value
Yes
40
00
No
01
* Auto restart is an emergency function such as for power failure etc.
Do not start and stop the indoor unit by this function in normal operation.
Be sure to operate by the control unit, or external input device.
5) Indoor room temperature sensor switching function
(Only for Wired remote controller)
The following settings are needed when use the control by Wired remote controller
temperature sensor.
(
... Factory setting)
Setting description
Function number
Setting value
No
42
00
Yes
01
* If setting value is “00” :
Room temperature is controlled by the indoor unit temperature sensor.
* If setting value is “01” :
Room temperature is controlled by either indoor unit temperature sensor or remote controller
unit sensor.
6) Remote controller signal code
Change the indoor unit Signal Code, depending on the remote controllers.
(
... Factory setting)
Setting description
Function number
Setting value
A
44
00
B
01
C
02
D
03
7) External input control
"Operation/Stop" mode or "Forced stop" mode can be selected.
(
... Factory setting)
Setting description
Function number
Setting value
Operation/Stop mode
46
00
(Setting forbidden)
01
Forced stop mode
02
Содержание AO*G09LTC
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LTCA AS G12LTCA DTR_AS054E_03 2011 11 14 ...
Страница 10: ... 01 07 WALL MOUNTED TYPE AS G09 12LT WALL MOUNTED TYPE AS G09 12LT INSTALLATION PLACE Unit mm ...
Страница 11: ... 01 08 WALL MOUNTED TYPE AS G09 12LT WALL MOUNTED TYPE AS G09 12LT WIRING DIAGRAMS 555 MODEL AS G09LT AS G12LT ...
Страница 19: ... 01 16 WALL MOUNTED TYPE AS G09 12LT WALL MOUNTED TYPE AS G09 12LT SOUND LEVEL CHECK POINT 88888 ...
Страница 31: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LTC AO G12LTC DTR_AO086E_01 2011 04 08 ...
Страница 37: ... 02 05 OUTDOOR UNIT AO G09 12LT OUTDOOR UNIT AO G09 12LT WIRING DIAGRAMS 444 MODEL AO G09LT ...
Страница 38: ... 02 06 OUTDOOR UNIT AO G09 12LT OUTDOOR UNIT AO G09 12LT MODEL AO G12LT ...
Страница 44: ... 02 12 OUTDOOR UNIT AO G09 12LT OUTDOOR UNIT AO G09 12LT SOUND LEVEL CHECK POINT 88888 ...