FUNCTION DETAILS
Functions
Compact wall
mounted
1) Filter sign
z
2) Cooler room temperature correction
z
3) Heater room temperature correction
z
4) Auto restart
z
5) Indoor room temperature sensor
switching function
z
6) Remote controller signal code
z
7) External input control
z
1) Filter sign
The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time
setting for the filter sign display interval in the table below according to the amount of dust or
debris in the room. If you do not wish the filter sign to be displayed, select the setting value for
"No indication".
(
... Factory setting)
Setting description
Function number
Setting value
Standard
11
00
Long interval
01
Short interval
02
No indication
03
The filter sign interval time is different according to Indoor unit type as follows.
Setting description
Compact Wall
Mounted
Standard
400 hours
Long interval
1000 hours
Short interval
200 hours
2) Cooler room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be selected as shown in the table below.
(
... Factory setting)
Setting description
Function number
Setting value
Standard
30
00
Slightly lower control
01
Lower control
02
Warmer control
03
3) Heater room temperature correction
Depending on the installed environment, the room temperature sensor may require a
correction.
The settings may be changed as shown in the table below.
(
... Factory setting)
Setting description
Function number
Setting value
Standard
31
00
Lower control
01
Slightly warmer control
02
Warmer control
03
Содержание AO*G09LTC
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LTCA AS G12LTCA DTR_AS054E_03 2011 11 14 ...
Страница 10: ... 01 07 WALL MOUNTED TYPE AS G09 12LT WALL MOUNTED TYPE AS G09 12LT INSTALLATION PLACE Unit mm ...
Страница 11: ... 01 08 WALL MOUNTED TYPE AS G09 12LT WALL MOUNTED TYPE AS G09 12LT WIRING DIAGRAMS 555 MODEL AS G09LT AS G12LT ...
Страница 19: ... 01 16 WALL MOUNTED TYPE AS G09 12LT WALL MOUNTED TYPE AS G09 12LT SOUND LEVEL CHECK POINT 88888 ...
Страница 31: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LTC AO G12LTC DTR_AO086E_01 2011 04 08 ...
Страница 37: ... 02 05 OUTDOOR UNIT AO G09 12LT OUTDOOR UNIT AO G09 12LT WIRING DIAGRAMS 444 MODEL AO G09LT ...
Страница 38: ... 02 06 OUTDOOR UNIT AO G09 12LT OUTDOOR UNIT AO G09 12LT MODEL AO G12LT ...
Страница 44: ... 02 12 OUTDOOR UNIT AO G09 12LT OUTDOOR UNIT AO G09 12LT SOUND LEVEL CHECK POINT 88888 ...