EXTERNAL INPUT & OUTPUT
11.
Connector INPUT
OUTPUT
REMARKS
CN303
Control input
-
See external
input/output settings
for details.
CN304
-
Operation status output
EXTERNAL INPUT
11-1.
CONTROL INPUT (Operation/Stop or Forced stop)
The air conditioner can be remotely operated by means of the following on-site work.
"Operation/Stop" mode or "Forced stop" mode can be selected with function setting of indoor unit.
Unit operation is started at the following contents by adding the contact input of a commercial ON/OFF switch to a
connector on the external control PC board and turning it ON.
Unit operation
Initial setting after power is ON
Starting mode other than initial setting
Operation mode
Auto changeover
Mode at previous operation
Set temperature
24°C
Temperature at previous operation
Air
fl
ow mode
AUTO
Mode at previous operation
Up-down air direction (swing)
Standard air direction (swing OFF)
Air direction at previous operation
Left-right air direction (swing)
Standard air direction (swing OFF)
Air direction at previous operation
Circuit diagram example
Signal
Field supply
Indoor unit
control PC board
Communication kit
Optional parts
Connector
1
3
*10 m
Connected unit
Ex.) Switch
* Make the distance from the PC board to the connected unit within 10m.
Contact capacity : 24VDC or more, 10mA or more.
Please use non-polar relays and switches.
When function setting is in "Operation/Stop" mode
Operation
Stop
ON
OFF
Input signal
Indoor unit
Содержание AO*G09LECAN
Страница 2: ...1 INDOOR UNIT WALL MOUNTED TYPE AS G09LECB AS G12LECB DTR_AS074E_01 2012 12 21 ...
Страница 19: ... 01 16 WALL MOUNTED TYPE AS G09 12LECB WALL MOUNTED TYPE AS G09 12LECB SOUND LEVEL CHECK POINT 8 2 ...
Страница 30: ...2 OUTDOOR UNIT SINGLE TYPE AO G09LECAN AO G12LECAN DTR_AO127E_01 2012 12 21 ...
Страница 35: ... 02 04 OUTDOOR UNIT AO G09 12LECAN OUTDOOR UNIT AO G09 12LECAN WIRING DIAGRAMS 4 MODEL AO G09LECAN AO G12LECAN ...
Страница 41: ... 02 10 OUTDOOR UNIT AO G09 12LECAN OUTDOOR UNIT AO G09 12LECAN SOUND LEVEL CHECK POINT 8 2 ...