Fujitsu Airstage UTY-RNRYZ3 Скачать руководство пользователя страница 1

En-1

1. SAFETY PRECAUTIONS

• The “SAFETY PRECAUTIONS” indicated in the manual contain impor-

tant information pertaining to your safety. Be sure to observe them.

• For details of the operation method, refer to the operating manual.
• Request the user to keep the manual on hand for future use, such as for 

relocating or repairing the unit.

 WARNING

Indicates a potentially or imminently hazardous situ-
ation which, if not avoided, could result in death or 
serious injury.

Installation of this product must be done by experienced service techni-
cians or professional installers only in accordance with this manual. 
Installation by nonprofessional or improper installation of the product 
may cause serious accidents such as injury, water leakage, electric 
shock, or 

fi

 re. If the product is installed in disregard of the instructions in 

this manual, it will void the manufacturer’s warranty.

Installation must be performed in accordance with regulations, codes, 
or standards for electrical wiring and equipment in each country, region, 
or the installing place.

Do not operate this unit when your hands are wet. Touching the unit with 
wet hands will cause an electric shock.

When children can approach the unit or touch the unit, take preventive 
measures.

Dispose of the packing materials safely. Tear and dispose of the plastic 
packing bags so that children cannot play with them. There is the dan-
ger of suffocation if children play with the original plastic bags.

 CAUTION

Indicates a potentially hazardous situation that may 
result in minor or moderate injury or damage to 
property.

When detecting the room temperature using the remote controller, 
please set up the remote controller according to the following conditions. 
If the remote controller is not well set, the correct room temperature will 
not be detected, and thus the abnormal conditions like “not cool” or “not 
heat” will occur even if the air-conditioner is running normally. :
• A location with an average temperature for the room being air condi-

tioned.

• Locate where is not be affected by in

fl

 ow of outside air such as caused 

by opening and closing a door.

• Not directly exposed to the outlet air from the air conditioner.
• Out of direct sunlight.
• Away from the in

fl

 uence of other heat sources.

REMOTE CONTROLLER
(WIRED TYPE)

INSTALLATION MANUAL

PART No. 9373328445
For authorized service personnel only.

[Original instructions]

Installation by endusers or not quali

fi

 ed persons can cause harm to 

personal safety, can cause severe damage to building and product, can 
lead to improper function or reduced lifetime of the equipment.

Do not install the unit in the following areas:
• Do not install the unit near a source of heat, steam, or 

fl

 ammable gas. 

Otherwise, 

fi

 re could result.

• Area 

fi

 lled with mineral oil or containing a large amount of splashed oil 

or steam, such as a kitchen. It will deteriorate plastic parts, causing the 
parts to fall.

• Area containing equipment that generates electromagnetic interfer-

ence. It will cause the control system to malfunction, and cause er-
roneous operation.

• Install the unit in a well-ventilated place avoiding rains and direct sun-

light.

Do not touch the switches with sharp objects. Doing so will cause injury, 
trouble, or electric shock.

Do not expose this unit directly to water. Doing so will cause trouble, 
electric shock, or heating.

Do not set vessels containing a liquid on this unit. Doing so will cause 
heating, 

fi

 re, or electric shock.

2.  MAIN UNIT AND ACCESSORIES

The following installation parts are supplied. Use them as required.

Name and shape

Q’ty

Name and shape

Q’ty

Wired remote controller

1

CD-ROM

1

Installation manual
(This manual)

1

Screw (M4 × 16mm)

For installing the remote 
controller

2

Operating manual

1

Cable tie

For binding remote 
controller and remote 
controller cable

1

3. ELECTRICAL REQUIREMENT

When connecting the remote controller use the following wiring.

Cable type

Size

Remarks

Sheathed cable

0.33 to 

1.25 mm²

Non polar 2 core, 

Twisted pair

Shielded cable*

* Use shielded cable in accordance with local rules for remote controller 

cable.

Select a 

fl

 exible cable that can be bound using cable ties from over the 

cable sheath inside this unit.

Maximum connectable number of remote controllers by cable size and the 
length.

Cable size

Max. connectable number of 

remote controllers

AWG

mm²

L* 

 100 m

101 m < L* 

 250 m

251 m < L* 

 500 m

VRF RAC VRF RAC VRF RAC

16

1.25

4

2

4

2

4

2

18

0.75 (1.25 > S* 

 

0.75)

4

2

4

2

2

2

20

0.5 (0.75 > S* 

 

0.5)

4

2

2

2

2

2

22

0.3 (0.5 > S* 

 

0.3)

4

2

1

1

1

1

*L: Total cable length, *S: Cable size

Deutsch

Français

Español

Italiano

E

λλη

vIk

ά

Português

Ру

сский

Türkçe

English

CONTENTS

1. SAFETY 

PRECAUTIONS 

.........................................................................1

2.  MAIN UNIT AND ACCESSORIES ............................................................1
3. ELECTRICAL 

REQUIREMENT 

................................................................1

4.  

SELECTING AN INSTALLATION LOCATION ..........................................2

5.  

INSTALLING THE REMOTE CONTROLLER ...........................................2

6.  SETTING THE REMOTE CONTROLLER ................................................5
7. TEST 

RUN 

................................................................................................9

8. ERROR 

CODES 

.......................................................................................9

Содержание Airstage UTY-RNRYZ3

Страница 1: ...328445 For authorized service personnel only Original instructions Installation by endusers or not qualified persons can cause harm to personal safety can cause severe damage to building and product can lead to improper function or reduced lifetime of the equipment Do not install the unit in the following areas Do not install the unit near a source of heat steam or flammable gas Otherwise fire cou...

Страница 2: ...remote controller inside If using the remote control sensor setting is required Refer to 6 3 5 RC Remote Controller Sensor Setting 4 3 Installation space Do not embed this remote controller in a wall Recommendation installation height of the remote controller is 1 4 m 55 in from the floor surface to the bottom of the remote controller Even when you install a remote controller to one of a switch bo...

Страница 3: ...mbine 3 Wired type with 2 Wired Type When there is a functional earthing Indoor unit Remote controller Remote controller Group control and multiple remote control can be used together 5 2 Preparing for Installation 5 2 1 Strip of the remote controller cable Sheathed cable A 7 mm 1 4 in B 7 mm 1 4 in C 25 mm 1 in Functional earthing Shielded cable A A B B C 5 2 2 Remove the front case When opening ...

Страница 4: ...te controller cable to the indoor unit One is the connection using connecting cable Included in the indoor unit and the other is the connection the remote controller cable is con nected to the exclusive terminal block of the indoor unit For the details refer to the installation manual of the indoor unit to be used 5 4 1 When connecting to the connector 1 Use a tool to cut off the terminal on the e...

Страница 5: ... and Time Setting screen The Time screen is displayed 1 2 3 Date and Time Setting Date 01 01 2015 Time 12 00 AM Thu 12 00AM Cancel OK Date Format Day Month Year Time Format 12 00 11 59AM PM Summer Time Setting Disable 2015 01 01 Thu 12 00AM Date Cancel OK Year Month Day Date and Time Setting Date 01 01 2015 Time 12 00 AM Thu 12 00AM Cancel OK Date Format Day Month Year Time Format 12 00 11 59AM PM...

Страница 6: ...t Day Month Year 12 00 11 59AM PM Month Dat Year Year Month Day Date Format Cancel OK Day Month Year Fri 10 00AM Display Format Setting Cancel OK Fri 10 00AM Date Format Time Format Day Month Year 12 00 11 59AM PM 4 Select and touch the data display format Touch OK on the Time Format to return to the Display Format Setting screen 5 Touch OK on the Display Format Setting screen to return to the Dat...

Страница 7: ...r Sign Visible Display Item Setting Cancel OK Room Temp Visible 6 3 9 RC Master Slave Setting If multiple remote controllers are set for a remote control group or for a single indoor unit it is necessary to set the remote controller master This setting will be required at the time of initial start up during installa tion However this setting can be changed afterwards No master remote controllers w...

Страница 8: ...te controller address 1 Touch the R C Address Setting on the Maintenance screen The R C Address Setting screen is displayed The Current Address is displayed as System Unit The value for Unit refers to the remote controller address 001 01 R C Address Setting Current Address Back Manual Addressing Address Reset Touch Back to return to the Maintenance screen When the address is set manually this mark...

Страница 9: ...gits 2 The Installer Password Change screen is displayed Enter the new password then touch the OK It returns to the Maintenance screen 1 2 0 0 CL 5 1 6 2 7 3 8 4 9 Cancel OK Installer Password Verification Enter Current Password 0 CL 5 1 6 2 7 3 8 4 9 Cancel OK Installer Password Change Enter New Password 6 4 10 Initialization Require an Installer password 1 Touch the Initialization on the Main te...

Отзывы: