SPECIFICATIONS

MODEL

AUUA

4

TLAV2

AUUA

7

TLAV2

AUUA

9

TLAV2

AUUA

12

TLAV2

AUUA

14

TLAV2

AUUA

18

TLAV2

AUUA

24

TLAV2

POWER SOURCE

208/230 V ~ 60 Hz

AVAILABLE 
VOLTAGE RANGE

187 to 253 V

COOLING 
CAPACITY

[Btu/h 

(kW)]

4,000 

(1.2)

7,500 

(2.2)

9,500 

(2.8)

12,000 

(3.5)

14,000 

(4.1)

18,000 

(5.3)

24,000 

(7.0)

HEATING 
CAPACITY

[Btu/h 

(kW)]

4,400 

(1.3)

9,500 

(2.8)

10,900 

(3.2)

13,500 

(4.0)

15,600 

(4.6)

20,000 

(5.9)

27,000 

(7.9)

SOUND PRESSURE LEVEL

HIGH

dB [A]

34/34 

(*1)

34

35

37

38

41

50

MED - 
HIGH

dB [A]

32/31 

(*1)

32

33

34

37

39

46

MED

dB [A]

30/29  

(*1)

30

31

33

34

36

43

MED - 
LOW

dB [A]

28/26 

(*1)

28

29

31

32

33

39

LOW

dB [A]

27/24 

(*1)

27

27

29

30

30

35

QUIET

dB [A]

25/21 

(*1)

25

25

27

27

27

30

DIMENSIONS & WEIGHT

HEIGHT

[in (mm)]

9-5/8 (245)

WIDTH

[in (mm)]

22-7/16 (570)

DEPTH

[in (mm)]

22-7/16 (570)

WEIGHT

[lbs (kg)]

32 

(14.5)

33 (15)

37 (17)

*1: This value is “cooling operation/heating operation”.

 

● Acoustic Noise Information: 

The maximum sound pressure level is less than 70 dB (A) for both 
indoor unit and outdoor unit. According to IEC 704-1 and ISO 3744.

Noise is heard:

 

● In the following conditions there are sounds of water fl owing from the 

indoor unit and the operation sound becomes loud. These are the 
sounds of the fl owing of refrigerant.
    When operation starts 

When oil recovery operation fi nishes 
When automatic defrosting operation fi nishes

 

● During operation, a slight squeaking sound may be heard. This is the 

result of minute expansion and contraction of the panel due to tem-
perature changes.

 

● During Heating operation, a sizzling sound may be heard occasionally. 

This sound is produced by the Automatic Defrosting operation. 
(See page 2.)

Smells:

 

● Some smell may be emitted from the indoor unit. This smell is the 

result of room smells (furniture, tobacco, etc.) which have been taken 
into the air conditioner.

Fog comes out of the indoor unit:

 

● During Cooling operation, a thin mist may be seen emitted from the 

indoor unit. This results from the sudden Cooling of room air by the air 
emitted from the air conditioner, resulting in condensation and mist-
ing.

Steam comes out of the indoor unit:

 

● During Heating operation, the outdoor unit’s fan may stop, and steam 

may be seen rising from the unit. This is due to the Automatic Defrost-
ing operation. (See page 2.)

Water is produced from the outdoor unit:

 

● During Heating operation, water may be produced from the outdoor 

unit due to the Automatic Defrosting operation.

The following conditions may not be breakdowns so 
check again.

Does not operate at all:

 

● Has there been a power failure?

 

● Has a fuse blown out, or a circuit breaker been tripped?

 

● Is the main power switch set to the OFF position?

 

● Are you trying to engage in an operation diff erent from the priority 

state? (See page 2.)

 

● Is it in standby state? (See page 2.)

The operation mode cannot be changed:

 

● Are you trying to change to an operation diff erent from the priority 

conditions? (See page 2.)

Poor Cooling (or Heating) performance:

 

● Did you adjust the room temperature settings (thermostat) correctly?

 

● Is the air fi lter dirty? (See page 3.)

 

● Are the air conditioner’s inlet port or outlet port blocked?

 

● Is there a window or door open?

 

● In the case of Cooling operation, is a window allowing bright sunlight to 

enter? (Close the curtains.)

 

● In the case of Cooling operation, are there heating apparatus and com-

puters inside the room, or are there too many people in the room?

 

● Is the fan speed set to low?

Set the temperature lower than the room temperature and use it:

 

● Temperature does not fall down well. Temperature may not fall down 

depending on the room conditions. (While high humidity or the room 
temperature is high.) (See page 2.)

In the following situations stop operation immediately 
and get in touch with authorized service personnel.

 

● The problem cannot be solved even when the troubleshooting checks 

have been performed.

 

● The FILTER indicator lamp (red) is fl ashing very fast.

 

● The wired remote controller or simple remote controller indicate Er 

(when connected).

 

● It has burning smell.

9369313349-01_OM.indb   4

9369313349-01_OM.indb   4

2019/9/6   13:27:51

2019/9/6   13:27:51

Содержание AirStage AUUA12TLAV2

Страница 1: ...eference MANUAL DE FUNCIONAMIENTO UNIDAD INTERIOR Tipo casete Conserve este manual para posibles consultas futuras MODE D EMPLOI UNITÉ INTÉRIEURE Type cassette Conservez ce manuel pour pour toute référence ultérieure English Español Français PART No 9369313349 9369313349 01_OM indb cover1 9369313349 01_OM indb cover1 2019 9 6 13 27 50 2019 9 6 13 27 50 ...

Страница 2: ...vy pressure to radiator fins Do not use flammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 40 in 1 m away from either the indoor or outdoor units This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of ex perience and knowledge unless they have ...

Страница 3: ...ame time in different mode Any indoor unit other than priority mode will wait in standby state until priority mode changes operation starts as soon as priority is switched At this time the OPERATION indicator lamp green lights up and the TIMER indicator lamp orange flashes limited to only when receiver unit is con nected Low ambient cooling When the outdoor temperature drops the outdoor unit s fans ...

Страница 4: ...hing alternately It has recovered from a power outage The OPERATION indicator lamp green and TIMER indicator lamp orange are flashing simultaneously It is operating in trial operation mode Ask a manager as there may be maintenance being conducted The OPERATION indicator lamp green lights up and the TIMER indicator lamp orange flashes This is the standby state See page 2 If the air conditioner is ope...

Страница 5: ...of room air by the air emitted from the air conditioner resulting in condensation and mist ing Steam comes out of the indoor unit During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to the Automatic Defrost ing operation See page 2 Water is produced from the outdoor unit During Heating operation water may be produced from the outdoor unit...

Страница 6: ...9369313349 01_OM indb 5 9369313349 01_OM indb 5 2019 9 6 13 27 51 2019 9 6 13 27 51 ...

Отзывы: