background image

En-2

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote controller is 
lost or otherwise unavailable.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 
control panel.

The operation can be set in the following setting.

Operating mode

AUTO:
When Auto mode cannot be selected, it will 
operate in the same mode as the other indoor 
unit in the same system. (When other indoor unit 
in the same system does not operate, the air 
conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature

74°F (23°C)

Stopping Operation

Press the MANUAL AUTO button on the operating 
control panel.

Emergency Heat

*  It is available when this function is enabled. Please consult an autho-

rized service personnel as to whether this function is eff ective.

Set emergency heat

During heating operation, press the MANUAL AUTO 
button on the operating control panel.

Auxiliary heater will be primary heater, and the outdoor unit will stop.
The OPERATION Indicator Lamp (Green) blinks during emergency heat-
ing operation. (3 seconds on, 1 second off .)

Cancel emergency heat

During emergency heating operation, press the MAN-
UAL AUTO button on the operating control panel.

ADJUSTING THE DIRECTION OF 
AIR CIRCULATION

The vertical wind direction can be controlled with the control unit.

Vertical direction

(1)

(2)

(3)

(4)

Cooling & Dry : (1), (2), (3), (4)
Heating : 

(1), (2), (3), (4)

OPERATING TIPS

Operation and Performance

About priority state and standby state

 

● Multiple indoor units can be connected within the same system. De-

pending on the system, choice of operating mode are limited.

Cooling priority 
state

When the other indoor units within the same system 
operate in cooling or dry mode, heating cannot be 
selected at the same time.

Heating priority 
state

When the other indoor units within the same system 
operate in heating mode, cooling and dry mode can 
not be selected at the same time.

Standby state

The standby state activates when 2 or more indoor 
units start up at the same time in diff erent mode. 
Any indoor unit other than priority mode will wait in 
standby state until priority mode changes (operation 
starts as soon as priority is switched).
At this time, the OPERATION indicator lamp (green) 
lights up and the TIMER indicator lamp (orange) 
fl ashes (limited to only when receiver unit is con-
nected).

Low ambient cooling

 

● When the outdoor temperature drops, the outdoor unit’s fans may 

switch to Low Speed, or one of the fans may stop intermittently.

Heating performance

 

● Heating mode operates on the heat-pump principle, absorbing heat 

from outdoor air and transferring that heat indoors. As a result, the 
operating performance is reduced as outdoor air temperature drops. 
If you feel that insuffi  cient heating performance is being produced, we 
recommend you use this air conditioner in conjunction with another 
type of heating appliance.

 

● Heating mode heat your entire room by recirculating air throughout the 

room, with the result that some time may be required after fi rst starting 
the air conditioner until the room is heated.

Microcomputer-controlled automatic defrosting

 

● When using the Heating mode under conditions of low outdoor air 

temperature high humidity, frost may form on the outdoor unit, result-
ing in reduced operating performance. In order to prevent this kind of 
reduced performance, this unit is equipped with a Microcomputer-con-
trolled automatic defrosting function. If frost forms, the air conditioner 
will temporarily stop, and the defrosting circuit will operate briefl y (for 
about 4 to 15 minutes). 
During Automatic Defrosting operation, the OPERATION indicator 
lamp (green) will fl ash.

Oil recovery operation

 

● Periodically, the oil recovery operation is performed in order to return 

compressor oil to the outdoor unit. During oil recovery operation, the 
OPERATION indicator lamp (green) will fl ash (for about 10 minutes).

Temperature and humidity range

 

● The temperature and humidity required for operating this product is as 

shown in the following table.

Cooling/Dry Mode

Heating Mode

Outdoor 
temperature

Please refer to the specifi cation of outdoor units.

Indoor 
temperature

About 64 to 90 °F DB 

(18 to 32 °C DB)

About 50 to 86 °F DB 

(10 to 30 °C DB)

Indoor humidity

About 80% or less

9369313349-01_OM.indb   2

9369313349-01_OM.indb   2

2019/9/6   13:27:51

2019/9/6   13:27:51

Содержание AirStage AUUA12TLAV2

Страница 1: ...eference MANUAL DE FUNCIONAMIENTO UNIDAD INTERIOR Tipo casete Conserve este manual para posibles consultas futuras MODE D EMPLOI UNITÉ INTÉRIEURE Type cassette Conservez ce manuel pour pour toute référence ultérieure English Español Français PART No 9369313349 9369313349 01_OM indb cover1 9369313349 01_OM indb cover1 2019 9 6 13 27 50 2019 9 6 13 27 50 ...

Страница 2: ...vy pressure to radiator fins Do not use flammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 40 in 1 m away from either the indoor or outdoor units This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of ex perience and knowledge unless they have ...

Страница 3: ...ame time in different mode Any indoor unit other than priority mode will wait in standby state until priority mode changes operation starts as soon as priority is switched At this time the OPERATION indicator lamp green lights up and the TIMER indicator lamp orange flashes limited to only when receiver unit is con nected Low ambient cooling When the outdoor temperature drops the outdoor unit s fans ...

Страница 4: ...hing alternately It has recovered from a power outage The OPERATION indicator lamp green and TIMER indicator lamp orange are flashing simultaneously It is operating in trial operation mode Ask a manager as there may be maintenance being conducted The OPERATION indicator lamp green lights up and the TIMER indicator lamp orange flashes This is the standby state See page 2 If the air conditioner is ope...

Страница 5: ...of room air by the air emitted from the air conditioner resulting in condensation and mist ing Steam comes out of the indoor unit During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to the Automatic Defrost ing operation See page 2 Water is produced from the outdoor unit During Heating operation water may be produced from the outdoor unit...

Страница 6: ...9369313349 01_OM indb 5 9369313349 01_OM indb 5 2019 9 6 13 27 51 2019 9 6 13 27 51 ...

Отзывы: