background image

En-3

Other optional parts

Description

Model

Application

IR receiver unit

UTY-TRHX

For the wireless remote controller.

Drain pump unit

UTZ-PU1NBA

Remote sensor

UTY-XSZX

Room temperature sensor

External connect kit

UTY-XWZXZC

For output function
(Output terminal / CNB01)

UTY-XWZXZB

For control input function
(Apply voltage terminal / CNA01)

UTY-XWZXZD

For control input function
(Dry contact terminal / CNA02)

UTY-XWZXZ7

For forced thermostat off function
(Apply voltage terminal / CNA03)

UTY-XWZXZE

For forced thermostat off function
(Dry contact terminal / CNA04)

Wireless LAN 

adapter

UTY-TFSXZ*

For wireless LAN control.

MODBUS® convertor UTY-VMSX

For connecting a single indoor unit 
system to the Modbus® network.

External power sup-

ply unit

UTZ-GXXA

Supply power to the indoor unit PCB 
when the indoor unit is turned off to 
prevent errors.

When installing, please refer to the installation manual of each optional part.

2.5. About unit of the length

This product is manufactured to metric units and tolerances. United States customary 
units are provided for reference only.
In cases where exact dimensions and tolerances are required, always refer to metric 
units.

3. INSTALLATION WORK

3.1. Selecting an installation location

Correct initial installation location is important because it is difficult to move unit after it is 
installed.

 

WARNING

Select installation locations that can properly support the weight of the indoor. Install the 
units securely so that they do not topple or fall.

 

CAUTION

Do not install the unit in the following areas:
• Area with high salt content, such as at the seaside. 

It will deteriorate metal parts, causing the parts to fail or the unit to leak water.

• Area filled with mineral oil or containing a large amount of splashed oil or steam, such 

as a kitchen. 
It will deteriorate plastic parts, causing the parts to fail or the unit to leak water.

• Area that generates substances that adversely affect the equipment, such as sulfuric 

gas, chlorine gas, acid, or alkali. 
It will cause the copper pipes and brazed joints to corrode, which can cause refrigerant 
leakage.

• Area that can cause combustible gas to leak, contains suspended carbon fibers or 

flammable dust, or volatile flammables such as paint thinner or gasoline. 
If gas leaks and settles around the unit, it can cause a fire.

• Area where animals may urinate on the unit or ammonia may be generated.

Do not use the unit for special purposes, such as storing food, raising animals, growing 
plants, or preserving precision devices or art objects. 
It can degrade the quality of the preserved or stored objects.

Do not install where there is the danger of combustible gas leakage.

Do not install the unit near a source of heat, steam, or flammable gas.

Install the unit where drainage does not cause any trouble.

Install the indoor unit, power supply cable, transmission cable, and remote controller 
cable at least 40 in (1 m) away from a television or radio receivers. The purpose of this 
is to prevent TV reception interference or radio noise.
(Even if they are installed more than 40 in (1 m) apart, you could still receive noise 
under some signal conditions.)

If children under 10 years old may approach the unit, take preventive measures so that 
they cannot reach the unit.

Decide the mounting position with the customer as follows:

(1)  Install the indoor unit on a place having a sufficient strength so that it withstands 

against the weight of the indoor unit.

(2)  The inlet and outlet ports should not be obstructed; the air should be able to blow all 

over the room.

(3)  Leave the space required to service the air conditioner.
(4)  A place from where the air can be distributed evenly throughout the room by the unit.
(5)  Install the unit where connection to the outdoor unit (or RB unit) is easy.
(6)  Install the unit where the connection pipe can be easily installed.
(7)  Install the unit where the drain pipe can be easily installed.
(8)  Install the unit where noise and vibrations are not amplified.
(9)  Take servicing, etc., into consideration and leave the spaces. Also install the unit 

where the filter can be removed.

(10)  Providing as much space as possible between the indoor unit and the ceiling will 

make work much easier.

(11)  If installing in a place where its humidity exceeds 80%, use heat insulation to prevent 

condensation.

3.2. Installation dimensions

Provide the space around the unit as 
shown in the following figure.
*1:  16 in (400 mm) or more when drain 

from drain pipe.

• Provide a service access for inspec-

tion purposes. 

• Do not place any wiring or illumina-

tion in the service space, as they will 
impede service.

• When an air filter is installed on the air 

inlet, provide enough service space to 
replace the filter.

Unit: in (mm)

16 (400) or 
more

6 (150) or 
more (*1)

[Top view] 

Unit: in (mm)

Air

Air

Service access

Indoor unit

12 (300) or more

20 (500) 
or more

20 (500) 

or more

4 (100)

[Top view] 

Unit: in (mm)

Air

Air

Service space

Indoor unit

12 (300) or more

62 (1,550) or more

20 (500) 

or more

4 (100)

3.3. Installing the unit

 WARNING

Install the air conditioner in a location which can withstand a load of at least 5 times the 
weight of the main unit and which will not amplify sound or vibration. If the installation 
location is not strong enough, the indoor unit may fall and cause injuries.

If the job is done with the panel frame only, there is a risk that the unit will come loose. 
Please take care.

3.3.1. Installing the hangers

Hanging bolt installation diagram.

[Top side] 

Unit: in (mm)

29-1/8 (740)

18-3/4 (477)

Air

Air

44-1

1/16 (1,135)

46-5/16 (1,177)

[Right side] 

Unit: in (mm)

10-5/8 (270)

Air

Air

9373385264-02_IM_L3.indb   Sec1:3

9373385264-02_IM_L3.indb   Sec1:3

9/24/2019   11:06:28 AM

9/24/2019   11:06:28 AM

Содержание Airstage ARUM24TLAV2

Страница 1: ...e For authorized service personnel only MANUEL D INSTALLATION UNITÉ INTÉRIEURE type conduit Pour le personnel agréé uniquement MANUAL DE INSTALACIÓN UNIDAD INTERIOR Tipo conducto Únicamente para personal de servicio autorizado 9373385264 02_IM_L3 indb 1 9373385264 02_IM_L3 indb 1 9 24 2019 11 06 28 AM 9 24 2019 11 06 28 AM ...

Страница 2: ...ng Keep your fingers and clothing away from any moving parts Clean up the site after you finish remembering to check that no metal scraps or bits of wiring have been left inside the unit being serviced After installation explain correct operation to the customer using the operating manual DANGER Never touch electrical components immediately after the power supply has been turned off Electrical shock ...

Страница 3: ...acuum pump can be used by installing a vacuum pump adapter Be sure that the pump oil does not backflow into the system Use one capable for vacuum suction of 500 microns 100 7 kPa Gas leakage detector Special gas leakage detector for HFC refrigerant R410A 2 3 Accessories WARNING For installation purposes be sure to use the parts supplied by the manufacturer or other prescribed parts The use of non ...

Страница 4: ...as Install the unit where drainage does not cause any trouble Install the indoor unit power supply cable transmission cable and remote controller cable at least 40 in 1 m away from a television or radio receivers The purpose of this is to prevent TV reception interference or radio noise Even if they are installed more than 40 in 1 m apart you could still receive noise under some signal conditions ...

Страница 5: ... exchanger may be clogged and its performance may decrease WARNING When fastening the hangers make the bolt positions uniform The distance of is adjustable according to the place of the hanging bolts MAX 21 5 8 in 550 mm MIN 16 1 8 in 410 mm Slide the unit in the arrow direction and fasten it Hanging bolt M10 locally purchased Special nut A accessories Washer locally purchased Special nut B access...

Страница 6: ...the humidity level at the installation location of the refrigerant piping is expected to exceed 70 install heat insulation around the refrigerant piping If the expected humidity level is 70 to 80 use heat insulation that is 9 16 in 15 mm or thicker and if the expected humidity exceeds 80 use heat insulation that is 13 16 in 20 mm or thicker If heat insulation is used that is not as thick as specif...

Страница 7: ... pipes Failure to do so may cause water leaks 5 INSTALLING DRAIN PIPES Use general hard polyvinyl chloride pipe and connect it with adhesive polyvinyl chloride so that there is no leakage Always heat insulate the indoor side of the drain hose Use a drain hose that matches the size of the drain pipe Do not perform a rise trap and air bleeding Provide a downward gradient 1 100 or more Provide suppor...

Страница 8: ...by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard CAUTION Earth Ground the unit Do not connect the earth ground cable to a gas pipe water pipe lightning rod or a telephone earth ground cable Improper earthing grounding may cause electric shock Do not connect power supply cables to the transmission or remote controller terminals as this will damage the ...

Страница 9: ... pressure bonding may malfunction and cause the cables to abnormally heat up B For strand wiring 1 Use ring terminals with insulating sleeves as shown in the figure below to connect to the terminal block 2 Securely clamp the ring terminals to the cables using an appropriate tool so that the cables do not come loose 3 Use the specified cables connect them securely and fasten them so that there is n...

Страница 10: ...tact terminal CNA04 DIP switch SET 2 SW2 Input signal type switching CNB01 Output terminal For external output CN8 For Remote sensor unit 1 CN48 For IR receiver unit 1 CN65 For one of the following MODBUS convertor 1 Wireless LAN adapter 1 CNA05 For Drain pump unit 1 CN106 CN820 For External power supply unit 1 1 For details refer to each installation manual 6 5 2 Power indicator lamp status Power...

Страница 11: ...CNA03 When a power supply must be provided at the input device you want to connect use the Apply voltage terminal CNA01 CNA03 a b 1 CNA01 CNA03 a a Input device 1 Input device 2 Input device 3 Load resistance Load resistance Load resistance DC power supply 12 to 24 V Connected unit P C B 1 Make the power supply DC 12 to 24 V Select a power supply capacity with an ample surplus for the connected lo...

Страница 12: ...nected unit P C B When connecting with unit equipped with a power supply CNB 01 P C B Connected device 1 Connected device 2 Connected device 3 Connected device 4 Connected unit Relay locally purchased Operation behavior If function setting 60 is set to 00 Connector Output voltage Status CNB01 External output 1 Pins 1 2 0 V Stop DC 12 V Operation External output 2 Pins 1 3 0 V Normal DC 12 V Error ...

Страница 13: ...Rotary switch setting Address Rotary switch setting Refrigerant circuit REF AD SW Indoor unit IU AD SW 10 1 10 1 0 0 0 0 0 0 1 0 1 1 0 1 2 0 2 2 0 2 3 0 3 3 0 3 4 0 4 4 0 4 5 0 5 5 0 5 10 1 0 10 1 0 11 1 1 11 1 1 99 9 9 63 6 3 7 2 Custom code setting Selecting the custom code prevents the indoor unit mix up Up to 4 codes can be set Perform the setting for both the indoor unit and the remote contro...

Страница 14: ... filter cleaning interval notification If the notification is too early change to setting 01 If the notification is too late change to setting 02 01 Longer 02 Shorter Filter indica tor action 13 00 Enable Enable or disable the filter indica tor Setting 02 is for use with a central remote controller 01 Disable 02 Display only on central remote controller Forbidden 20 00 Forbidden 23 00 Forbidden 24...

Страница 15: ... F 0 5 C t 1 8 F 1 C t 0 F 0 C 08 t 3 6 F 2 C t 0 9 F 0 5 C t 3 6 F 2 C t 0 F 0 C 09 t 5 4 F 3 C t 0 9 F 0 5 C t 5 4 F 3 C t 0 F 0 C 10 t 7 2 F 4 C t 0 9 F 0 5 C t 7 2 F 4 C t 0 F 0 C 11 t 9 0 F 5 C t 0 9 F 0 5 C t 9 0 F 5 C t 0 F 0 C 12 t 5 4 F 3 C t 0 F 0 C t 0 9 F 0 5 C t 0 9 F 0 5 C 13 t 3 6 F 2 C t 0 F 0 C t 1 8 F 1 C t 0 9 F 0 5 C 14 t 3 6 F 2 C t 0 F 0 C t 3 6 F 2 C t 0 9 F 0 5 C 15 t 5 4 F...

Страница 16: ...or 4 1 Indoor unit room temp therm istor error 4 2 Indoor unit heat ex temp thermistor error 5 1 Indoor unit fan motor 1 error 5 2 Indoor unit coil expansion valve error 5 3 Indoor unit water drain abnormal 9 15 Outdoor unit miscellaneous error 10 8 Poor refrigerant circulation 13 1 RB unit error Display mode 0 5 s ON 0 5 s OFF 0 1 s ON 0 1 s OFF Number of flashing Wired Remote Controller Display ...

Отзывы: