6-2. Model: AOUH12LUAS1
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length
m
5
7.5
10
15
20
ft
16
25
33
49
66
Height difference H
Indoor unit is higher than outdoor
unit *1
15
49
-
-
-
0.877
0.874
10
33
-
-
0.956
0.891
0.888
7.5
25
-
0.988
0.960
0.895
0.892
5
16
1.017
0.992
0.964
0.899
0.895
0
0
1.025
1.000
0.971
0.906
0.902
Indoor unit is lower than outdoor
unit *2
-5
-16
1.025
1.000
0.971
0.906
0.902
-7.5
-25
-
1.000
0.971
0.906
0.902
-10
-33
-
-
0.971
0.906
0.902
-15
-49
-
-
-
0.906
0.902
HEATING
Pipe length
m
5
7.5
10
15
20
ft
16
25
33
49
66
Height difference H
Indoor unit is higher than outdoor
unit *1
15
49
-
-
-
0.933
0.925
10
33
-
-
0.981
0.933
0.925
7.5
25
-
1.000
0.981
0.933
0.925
5
16
1.017
1.000
0.981
0.933
0.925
0
0
1.017
1.000
0.981
0.933
0.925
Indoor unit is lower than outdoor
unit *2
-5
-16
1.012
0.995
0.976
0.928
0.920
-7.5
-25
-
0.993
0.974
0.926
0.918
-10
-33
-
-
0.971
0.923
0.916
-15
-49
-
-
-
0.914
0.906
- 83 -
6-2. Model: AOUH12LUAS1
6. Capacity compensation rate for pipe length and height difference
OUTDOOR UNIT
AOUH09-18LUAS1
OUTDOOR UNIT
AOUH09-18LUAS1