- (01-170) -
M
U
L
T
I T
Y
P
E
2
, 3
, 4 R
O
O
M
S T
Y
P
E
M
U
L
T
I T
Y
P
E
2
, 3
, 4 R
O
O
M
S T
Y
P
E
COMPLETION OF FUNCTION SETTING MODE
6) When [Cancel button] is pressed twice while “Function setting” screen is displayed, it
switches to the “Submenu” screen.
Back:
Setting:
Date and time
Submenu
[
1/2
]
Monitor
Screen
Filter sign
R.C. sensor control
Room temp. display
Off
Off
Mo 10:00AM
Cancel: OK:
Function setting
Mo 10:00AM
R.C. Function Setting
address No. No.
Version Error history
00
30
01
* If no key entry is made for 60 seconds, even though none of the above buttons is pressed,
the function setting mode will automatically be cleared.
(If the function setting mode is automatically cleared while setting addresses, activate the
mode again according to the procedure in step 2).
SETTING UP EACH INDOOR UNIT
Repeat the procedures in steps 1) through 6), and set up the indoor units requiring function
setting.
RESET THE POWER AFTER SETTING UP FUNCTION OF ALL
INDOOR UNITS
Important
If the reset is not performed, function settings cannot be read in normally.
After all the functions have been set, the circuit breaker needs to be switched off
for at least 2 minutes.
After the 2 minutes has passed, power can be restored.
The set function is stored in the PCB and will remain in memory even when the
power is turned off.
However the function setting are only effective after the power is reset.
Record the function settings of the indoor unit on a label, etc., and affix the label to
the unit so it can be used for after-sales service operations.
Содержание AB*G14LVTA
Страница 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Страница 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Страница 75: ... 01 71 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE MODELS AS G18LFCA AS G24LFCA AS G24LFCC ...
Страница 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Страница 199: ... 02 03 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 DIMENSIONS 222 MODEL AO G14L2 AO G18L2 Unit mm ...
Страница 201: ... 02 05 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 REFRIGERANT CIRCUIT 333 MODEL AO G14L2 ...
Страница 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Страница 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Страница 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Страница 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Страница 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Страница 236: ... 03 04 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 REFRIGERANT CIRCUIT 333 MODEL AO G18L3 AO G24L3 ...
Страница 237: ... 03 05 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 WIRING DIAGRAMS 444 MODEL AO G18L3 AO G24L3 F4 FUSE T 5A 250V ...
Страница 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Страница 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Страница 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Страница 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...