- (01-168) -
M
U
L
T
I T
Y
P
E
2
, 3
, 4 R
O
O
M
S T
Y
P
E
M
U
L
T
I T
Y
P
E
2
, 3
, 4 R
O
O
M
S T
Y
P
E
MODEL: UTY-RVN
13-3-2.
M
SWITCHING SELECTION OF FUNCTION SETTING MODE
2) When [Menu button] is pressed twice while “Monitor” screen is displayed, it switches to the
“Submenu” screen. If [Menu button] is pressed while the “Submenu” screen is displayed, the
display returns to the “Monitor” screen.
Back:
Setting:
Date and time
Submenu
[
1/2
]
Monitor
Screen
Filter sign
R.C. sensor control
Room temp. display
Off
Off
Mo 10:00AM
Menu
Monitor
O f f
Mo 10:00AM
Press the [Screen switch button (Left)] and [Screen switch button (Right)] simultaneously for 5
seconds to switch to “Service” screen.
Back: Setting:
Service
Mo 10:00AM
Function setting
Error history
I.U.address verification
Version
Test run
Back:
Setting:
Date and time
Submenu
[
1/2
]
Monitor
Screen
Filter sign
R.C. sensor control
Room temp. display
Off
Off
Mo 10:00AM
Select [Function setting] with pressing the [Cursor button (Up/Down)], and press the [Enter
button].
Back: Setting:
Service
Mo 10:00AM
Function setting
Error history
I.U.address verification
Version
Test run
Cancel: OK:
Function setting
Mo 10:00AM
R.C. Function Setting
address No. No.
00
00 00
Version Error history
Содержание AB*G14LVTA
Страница 62: ... 01 58 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE ...
Страница 64: ... 01 60 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE INSTALLATION PLACE Unit mm ...
Страница 75: ... 01 71 MULTI TYPE 2 3 4 ROOMS TYPE MULTI TYPE 2 3 4 ROOMS TYPE MODELS AS G18LFCA AS G24LFCA AS G24LFCC ...
Страница 195: ...2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE AO G14LAC2 AO G18LAC2 DTR_AO082E_07 2014 05 30 ...
Страница 199: ... 02 03 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 DIMENSIONS 222 MODEL AO G14L2 AO G18L2 Unit mm ...
Страница 201: ... 02 05 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 REFRIGERANT CIRCUIT 333 MODEL AO G14L2 ...
Страница 202: ... 02 06 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Страница 203: ... 02 07 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 WIRING DIAGRAMS 444 MODEL AO G14L2 ...
Страница 204: ... 02 08 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 MODEL AO G18L2 ...
Страница 227: ... 02 31 OUTDOOR UNIT AO G14 18L2 OUTDOOR UNIT AO G14 18L2 SOUND LEVEL CHECK POINT 99999 ...
Страница 231: ...3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE AO G18LAT3 AO G24LAT3 DTR_AO083E_07 2014 05 30 ...
Страница 236: ... 03 04 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 REFRIGERANT CIRCUIT 333 MODEL AO G18L3 AO G24L3 ...
Страница 237: ... 03 05 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 WIRING DIAGRAMS 444 MODEL AO G18L3 AO G24L3 F4 FUSE T 5A 250V ...
Страница 279: ... 03 47 OUTDOOR UNIT AO G18 24L3 OUTDOOR UNIT AO G18 24L3 SOUND LEVEL CHECK POINT 99999 ...
Страница 283: ...4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE AO G30LAT4 DTR_AO078E_08 2014 05 30 ...
Страница 289: ... 04 05 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 WIRING DIAGRAMS 444 MODEL AO G30L4 ...
Страница 357: ... 04 73 OUTDOOR UNIT AO G30L4 OUTDOOR UNIT AO G30L4 SOUND LEVEL CHECK POINT 99999 ...