En-3
5.3. Outdoor unit wiring
(1) Remove the outdoor unit connector cover.
(2) Bend the end of the cable as shown in the
fi
gure.
(3) Connect the end of the connection cable fully into the terminal block.
(4) Fasten the sheath with a cable clamp.
(5) Install the connector cover.
Control box
Control box cover
cable clamp
Connection cable
1
2
3
N
L
1
2
3
L
N
1
2
3
4
Outdoor unit terminal block
Indoor unit terminal block
Connection cable
Power supply cable
Earth screw
Earth screw
20mm
12mm
5mm
5mm
12mm
20mm
20mm
12mm
5mm
5mm
12mm
20mm
Connection cable
Power supply cable
Cable clamp
Earth
screw
Earth
screw
Connection cable wiring
Run the connection cable to the rear of the outdoor unit within the
A
range of the arrows shown in the
fi
gure.
(The connector cover becomes dif
fi
cult to install.)
Connection cable
10 cm 5 cm
How to
fi
xed connection cable and power supply cable at the cable clamp
After passing the connection cable and power supply cable through the insulation tube,
fasten it with the cable clamp.
Insulation tube
Insulation tube
Cable clamp
Use VW-1, 1.0 mm thick, PVC tube as the insulation tube.
5.4. HOW TO CONNECT THE WIRE TO THE TERMINALS
(1) Use crimp-type terminals with insulating sleeves as shown in the
fi
gure below to con-
nect to the terminal block.
(2) Securely crimp the crimp-type terminals to the wires using an appropriate tool so that
the wires do not come loose.
(3) Use the speci
fi
ed wires, connect them securely, and fasten them so that there is no
stress placed on the terminals.
(4) Use an appropriate screwdriver to tighten the terminal screws. Do not use a screw-
driver that is too small, otherwise, the screw heads may be damaged and prevent the
screws from being properly tightened.
(5) Do not tighten the terminal screws too much, otherwise, the screws may break.
(6) See the table below for the terminal screw tightening torques.
Tightening torque
M4 screw
1.2 to 1.8 N • m (12 to 18 kgf • cm)
M5 screw
2.0 to 3.0 N • m (20 to 30 kgf • cm)
4. INSTALLATION DIAGRAM
• Do not directly install it on the
ground, otherwise it will cause
failure.
• To obtain better operation ef-
ficiency, when the outdoor unit
is installed, be sure to open the
front and left side.
10 cm or over
60 cm or over
10 cm or over
20 cm or over
25 cm or
over
5 cm or over
INDOOR UNIT
[OUTDOOR UNIT]
54 cm
32 cm
Outdoor
unit bottom
Drain hose
CAUTION
When the outdoor temperature is 0
˚
C or less, do not use the accessory drain pipe
and drain cap. If the drain pipe and drain cap are used, the drain water in the pipe may
freeze in extreme cold weather. (Reverse cycle model only)
In the area with heavy snowfall, if the intake and outlet of outdoor unit is blocked with
snow, it might become dif
fi
cult to get warm and it is likely to cause of the breakdown.
Please construct a canopy and a pedestal or place the unit on a high stand (local
con
fi
gured).
5. INSTALLATION
5.1. Outdoor unit installation
Set the unit on a strong stand such as thing made of concrete blocks to minimize shock and vibration.
Do not set the unit directly on the ground because it will cause trouble.
WARNING
Install the unit where it will not be tilted by more than 5°.
When installing the outdoor unit where it may exposed to strong wind, fasten it securely.
5.2. Connector cover remove
Connector cover removal
Remove the tapping screw.
Installing the connector cover
(1) After inserting the four hooks, then slide
the cover.
(2) Tighten the tapping screw.
Tapping screw
Hooks
Connector cover
Hooks
9316421073_IM.indb 3
9316421073_IM.indb 3
2012-10-29 9:36:51
2012-10-29 9:36:51