background image

En-7

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

Human Sensor (Energy Saving)

To prevent waste of electricity, this function controls the temperature 
setting when no one is occupying the room. Energy Saving program is 
on at the time of purchase.

1.

  To activate the Energy Saving program, press the SENSOR button.

 indicator will be 

fl

 ashing on the remote controller 

display.

2.

  To deactivate the Energy Saving program, press the SENSOR 

button again.

 will no longer be shown on the remote controller 

display.

About the ENERGY SAVING Operation

If no one enters the room for approximately 20 minutes, the set 
temperature will be automatically controlled. 
(When someone comes back into the room, the human sensor will 
detect this, and automatically revert to the original settings.)

Operation 

mode

Operating details 

(if there is no one in the room for a while)

COOL/DRY

The set temperature will be increased by a maximum of 
approximately 4°F (2°C).

HEAT

The set temperature will be decreased by a maximum 
of approximately 8°F (4°C).

AUTO

This runs the ENERGY SAVING function automatically 
for the selected mode (Cooling/ Heating/ Drying).

 When using together with the SLEEP timer (page 6), the SLEEP 

timer will be prioritized.

 During MIN. HEAT operation, if there is no one in the room the set 

temperature will not be changed.

90°

22 ft (7 m)

22 ft 

(7 m)

50°

50°

  Application range is follows.

Vertical angle 90° (Side view)

Horizontal angle 100° (Top view)

ENERGY SAVING function may not work when the room temperature is 
very different from the temperature de

fi

 ned in temperature setting, such 

as when immediately after starting the operation.

About the HUMAN SENSOR

 

Details about detection with the human sensor

 

 The human sensor detects whether there are people in the room 

by looking for movement by people in the room.

 

Since the human sensor detects infrared light given out by 

people, there may be cases where this detection is incorrect.

Situations in which the sensor will detect no people in the 
room, even when there is someone there

 

 When the temperature is high and the difference with be-

tween people’s body temperature is small. 
(Such as during the summer when the temperature is 88°F 
(30°C) or higher)

 

 When there is someone in the room, but they do not move 

for a long period of time.

 

 When someone is hidden behind a sofa, other furniture, 

glass, or in similar situations.

 

 When someone is wearing extremely thick clothing and has 

their back facing the sensor.

Situations in which the sensor will incorrectly detect people 
in the room, even when there is no one there

 

 When there is a dog or a cat moving around in the room.

 

 When the wind is making curtains or plants move.

 

 When there are heating units, humidi

fi

 ers, or electric appli-

ances such as oscillating electric fans operating.

Notice

 Auto-restart function

In event of power interruption such as a blackout, the air 
conditioner stops once. But it restarts automatically and 
performs previous operation when the power supply is resumed.

If any power interruption occurs after the timer is set, counting 
down of the timer will be reset. 
After the power supply is resumed, the TIMER indicator on the 
indoor unit blinks to notify you that there has been a timer fault. 
In such a case, reset the timer for your opportune time.

Malfunctions caused by other electrical devices:

Use of other electrical appliances such as an electric shaver or 
nearby use of a wireless radio transmitter may cause the malfunction 
of the air conditioner. 
If you encounter such a malfunction, turn off the circuit breaker once. 
Then turn it on again, and resume operation by using the remote 
controller.

 Automatic defrosting operation

When outdoor temperature is very low with high humidity, frost 
may form on the outdoor unit during the heating operation, and 
it could reduce the operating performance of the product. 
For frost protection, a microcomputer-controlled automatic 
defrost function is equipped in this air conditioner. 
If frost forms, the air conditioner will temporarily stop, and 
defrost circuit will operate brie

fl

 y (maximum of 15 minutes.)

OPERATION indicator on the indoor unit blinks during this 
operation. 
If frost forms on the outdoor unit after the heating operation, the 
outdoor unit will stop automatically after it operates for a few 
minutes. Then the automatic defrosting operation starts.

General Informations on Operation

9320455026_OM.indb   7

9320455026_OM.indb   7

12/4/2014   5:04:52 PM

12/4/2014   5:04:52 PM

Содержание 9-12-15RLS3

Страница 1: ... water containers on top of air conditioners Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power...

Страница 2: ...r the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 In SWING operation power diffuser does not move 7 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow dire...

Страница 3: ...essed from a distance Notes Use specified type of batteries only Do not mix different types or new and used batteries together Batteries can be used about 1 year in ordinary use If the remote control range noticeably shortens replace the batter ies and press RESET button as shown in page 4 Remote Controller Overview and Operations You can quickly start operation with the following 3 steps 1 START ...

Страница 4: ...flow direction louver The Up down Swing operation range will differ by mode as follows COOL DRY or FAN mode HEAT or FAN mode 1 2 3 4 8 7 6 5 5 1 2 3 4 5 6 7 8 Notes SWING operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped In FAN mode the Up down swing operation range of 1 5 or 6 8 is decided according to the airflow direction previously set before s...

Страница 5: ...P button to change the custom code between A B C D Match the code on the display to the air conditioner custom code 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 Timer Operation Remote Con...

Страница 6: ...time the air conditioner will run in the order of the program number If there is a power interruption such as due to a power outage during the WEEKLY timer setting or a circuit breaker cutting out the internal timer of the air conditioning will be incorrect See page 7 Auto restart In such a case the main timer lamp will notify you of this by flashing so carry out matching of the time and date See ...

Страница 7: ...ween people s body temperature is small Such as during the summer when the temperature is 88 F 30 C or higher When there is someone in the room but they do not move for a long period of time When someone is hidden behind a sofa other furniture glass or in similar situations When someone is wearing extremely thick clothing and has their back facing the sensor Situations in which the sensor will inc...

Страница 8: ...the indoor unit body mind the following Do not use water hotter than 104 F 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner Wipe the unit gently by using soft cloth Cleaning the intake grille 1 Open the intake grille in direction of the arrow a While gently pressing the left and right mounting shafts of the intake grille outward b remove the intake grille in direction...

Страница 9: ...AN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In such a case the product inspection is recommended For more inform...

Страница 10: ...unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 7 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUI...

Отзывы: