background image

En-5

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

The air conditioner custom code is set to A prior to shipment.
Contact your retailer to change the custom code.

The remote controller resets to custom code A when the batteries in 
the remote controller are replaced. If you use a custom code other 
than custom code A, reset the custom code after replacing the bat-
teries. If you do not know the air conditioner custom code setting, try 
each of the custom codes (A 

 B 

 C 

 D) until you 

fi

 nd the code 

which operates the air conditioner.

 Wired Remote Controller (Option)

The optional wired remote controller can be used.
When you use remote controller, there are following different points as 
compared with using wireless remote controller.
[The additional functions for wired ones]
  • Weekly timer
  • Temperature set back timer
And you can use both wired and wireless remote controller simultane-
ously.
(But function is limited)
When the restricted functions on the remote controller are used, beep-
ing sound will be heard, OPERATION, TIMER and the 3rd lamp of the 
indoor unit will 

fl

 ash.

[The restricted functions for wireless ones]
  • SLEEP TIMER
  • ON/OFF TIMER
  • PROGRAM TIMER
  • WEEKLY TIMER
  • MIN. HEAT OPERATION
  • POWERFUL OPERATION
  • ENERGY SAVING PROGRAM
  • OUTDOOR UNIT LOW NOISE OPERATION

See page 7

N

SENSOR button (ENERGY SAVING PROGRAM)

Activates or deactivates the energy saving program. 
* The Energy Saving program is ON at the time of purchase.

:  

The setting must be done while the setting screen is displayed for 
each function.

 :  The button is controllable only when the air conditioner is on.

 Remote controller custom code setting

Use the following steps to select the custom 
code of the remote controller.
(Note that the air conditioner cannot receive 
a custom code if the air conditioner has not 
been set for the custom code.)
1.  Press the START/STOP button until only the 

clock is displayed on the remote controller 
display.

2.  Press the MODE button for at least 

fi

 ve 

seconds to display the current custom code 
(initially set to A).

3.  Press the SET TEMP. (  /  ) button to change the custom code 

between A 

 B 

 C 

 D.

Match the code on the display to the air conditioner custom code.

4.  Press the MODE button again to return to the clock display. The 

custom code will be changed.

If no buttons are pressed within 30 seconds after the custom code 
is displayed, the system returns to the original clock display. In this 
case, start again from step 1.

Timer Operation

Remote Controller Overview and Operations

Note for timer settings:

Any interruption of the power supply, such as a blackout or cutting off of a circuit breaker, makes the set internal clock go wrong.
In such a case, the TIMER indicator on the indoor unit blinks, and you need to readjust the setting.

ON timer or OFF timer

You can set the ON timer or OFF timer with the following steps.

1.

  Press the TIMER SETTING button to start the setting.

The WEEKLY indicator will be 

fl

 ashing on the remote controller.

2.

  Press the SELECT button to choose the desired mode. The mode 

will change as follows:

WEEKLY

ON/OFF

(ON)

ON/OFF

(OFF)

ON/OFF

(ON

OFF)

SLEEP

(OFF)

3.

  Press the NEXT button. Continue to setting for each mode.

* To cancel timer setting during the setting process, press the 

TIMER SETTING button again.

4.

  Adjust the time by pressing the SELECT button while the clock 

indicator is blinking. Each time you press the button, the time will 
change by +5/-5 minutes. Pressing down will change the time by 
+10/-10 minutes.

5.

  Press the SEND button.

To redo the timer setting, perform step 1 to 5 again.
To cancel the ON/OFF timer, press the ON/OFF button while the ON/
OFF indicator is on. (Erases the indicator)

Program timer (combined use of the ON timer and the OFF timer)

You can set an integrated ON–OFF or OFF–ON timer.
Either of the timer whose con

fi

 gured starting time is closer to the 

current time works 

fi

 rst, and the order of timer operation is displayed 

as follows:

Timer

Indicator on remote controller display

ON–OFF timer

OFF–ON timer

To set the program timer, conduct the same steps 

~

 for the ON/

OFF timer. (Select ON

OFF in Step 2)

Notes:

• If you change the setting value for the timer after the program timer 

is set, the counting down of the timer will be reset at that moment.

• Time setting for each combination should be within a span of 24 hours.

(continued)

9320455026_OM.indb   5

9320455026_OM.indb   5

12/4/2014   5:04:49 PM

12/4/2014   5:04:49 PM

Содержание 9-12-15RLS3

Страница 1: ... water containers on top of air conditioners Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power...

Страница 2: ...r the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 In SWING operation power diffuser does not move 7 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow dire...

Страница 3: ...essed from a distance Notes Use specified type of batteries only Do not mix different types or new and used batteries together Batteries can be used about 1 year in ordinary use If the remote control range noticeably shortens replace the batter ies and press RESET button as shown in page 4 Remote Controller Overview and Operations You can quickly start operation with the following 3 steps 1 START ...

Страница 4: ...flow direction louver The Up down Swing operation range will differ by mode as follows COOL DRY or FAN mode HEAT or FAN mode 1 2 3 4 8 7 6 5 5 1 2 3 4 5 6 7 8 Notes SWING operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped In FAN mode the Up down swing operation range of 1 5 or 6 8 is decided according to the airflow direction previously set before s...

Страница 5: ...P button to change the custom code between A B C D Match the code on the display to the air conditioner custom code 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 Timer Operation Remote Con...

Страница 6: ...time the air conditioner will run in the order of the program number If there is a power interruption such as due to a power outage during the WEEKLY timer setting or a circuit breaker cutting out the internal timer of the air conditioning will be incorrect See page 7 Auto restart In such a case the main timer lamp will notify you of this by flashing so carry out matching of the time and date See ...

Страница 7: ...ween people s body temperature is small Such as during the summer when the temperature is 88 F 30 C or higher When there is someone in the room but they do not move for a long period of time When someone is hidden behind a sofa other furniture glass or in similar situations When someone is wearing extremely thick clothing and has their back facing the sensor Situations in which the sensor will inc...

Страница 8: ...the indoor unit body mind the following Do not use water hotter than 104 F 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner Wipe the unit gently by using soft cloth Cleaning the intake grille 1 Open the intake grille in direction of the arrow a While gently pressing the left and right mounting shafts of the intake grille outward b remove the intake grille in direction...

Страница 9: ...AN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In such a case the product inspection is recommended For more inform...

Страница 10: ...unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 7 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUI...

Отзывы: