5-6
Symptom
2
NO
NO
YES
YES
YES
NO
Are the documents loaded
properly? (Straight edge,
no dogear, no bend
corners, staples)
Is the interface cable
connected properly?
Or is the baud rate
correct?
(Video, RS-232C, or
SCSI interfaces)
Load the documents properly.
(See p1-5)
Connect the interface cable
properly.
Or set the correct baud rate.
Read processing does not start.
Interface cable
Turn the power off and on to check if read
processing starts.
When read processing does not start, contact a
manufacturer’s authorized service center.
CHECK
Operator panel
POWER
Does the CHECK lamp
blink?
Messages and Actions
(See p5-13)
Operator panel
Document
or