background image

RX220

Service Supplement

7

Notational conventions

1.2

Notational conventions

The following notational conventions are used in this manual:

Replacement routines:

Replacing the system fans

Replacing the control panel board

Replacing the power supply unit

Replacing the internal server power supply 
cable

Replacing the chassis ID module

Replacing the non-hot-plug hard disk

Replacing the SATA backplane

Replacing the fan backplane

Replacing the system board

Service Supplement

Board layout

Cabling

BIOS settings

D2130 Setup Utility

Italics

indicate commands, menu items or software programs.

“Quotation marks”

indicate names of chapters and terms that should be 
emphasized.

Ê

text which follows this symbol describes activities that 
must be performed in the order shown.

V

CAUTION!

pay particular attention to text marked with this symbol. 
Failure to observe this warning may endanger your life, 
damage the server, or lead to loss of data.

I

supplementary information, remarks and tips follow this 
symbol.

Table 2: Notational conventions

Information/activity

Manual

Table 1: Overview of the RX220 documentation

Содержание Primergy RX220

Страница 1: ...20 Server System Service Supplement Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 81730 Munich e mail email manuals fujitsu siemens com Tel 05251 8 14884 Fax 49 700 372 00000 RX220 Sprachen En Edition January 2006 ...

Страница 2: ...according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001 2000 cognitas Gesellschaft für Technik Dokumentation mbH www cognitas de Copyright and Trademarks Copyright 2006 Fujitsu Siemens Computers Gmb...

Страница 3: ...l panel board 25 4 4 Replacing the power supply unit 27 4 5 Replacing the internal server power supply cable 31 4 6 Replacing the chassis ID module 33 4 7 Replacing the non hot plug hard disk 34 4 8 Replacing the SATA backplane 36 4 9 Replacing the fan backplane 37 4 10 Replacing the system board 38 5 Appendix 41 5 1 Board layout 41 5 1 1 Control panel board 41 5 1 2 SATA backplane 42 5 1 3 Fan ba...

Страница 4: ......

Страница 5: ...e performed by service personnel Service DVD A service DVD PRIMERGY is available for Fujitsu Siemens service partners This DVD contains the following manuals as PDF files The Safety manual The Operating Manual for the PRIMERGY RX220 The Technical Manual for the system board D2130 The Options Guide for the PRIMERGY RX220 The D2130 Setup Utility for RX220 manual The Service Supplement for the PRIMER...

Страница 6: ... nents Hot plug HDD modules Information about the system board Features of the system board Board layout Jumper settings Replacing the battery Technical Manual Extensions and upgrades I For some components only the instal lation routine is described in the Options Guide Removing this components proceed in reverse order Extending replacing main memory Installing a second processor replacing the pro...

Страница 7: ...em board Service Supplement Board layout Cabling BIOS settings D2130 Setup Utility Italics indicate commands menu items or software programs Quotation marks indicate names of chapters and terms that should be emphasized Ê text which follows this symbol describes activities that must be performed in the order shown V CAUTION pay particular attention to text marked with this symbol Failure to observ...

Страница 8: ......

Страница 9: ...y need the Operating Manual for the server and the Options Guide for the server the Technical Manual for the system board Ê Shut down the server correctly switch it off pull out the power plug and open the server as described in the chapter Replacement routines on page 17 Ê Replace the defective component as described in the relevant chapter Ê Close the server Ê Connect up the server cables 1 Ê Co...

Страница 10: ......

Страница 11: ...chine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed Transport the device only in its original packaging or in packaging which protects it from knocks and jolts Installation and operation V CAUTION If the rack model is integrated in an installation that receives p...

Страница 12: ...quirements apply in accordance with the standards EN 50173 and EN 50174 1 2 As minimum requirement the use of a protected LAN line of category 5 for 10 100 MBps Ethernet and or of category 5e for Gigabit Ethernet is considered The requirements of the specification ISO IEC 11801 are to be considered Route the cables in such a way that they do not form a potential hazard and that they cannot be dama...

Страница 13: ... and refresh rates specified in the Technical data section of the monitor description Otherwise you may damage your monitor Batteries V CAUTION Incorrect replacement of batteries may lead to risk of explosion The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer see the Technical Manual for the system board Do not throw batteries into the trash ...

Страница 14: ...amaged and imbalanced CDs DVDs can break at high drive speeds data loss Under certain conditions sharp edged pieces of broken CDs DVDs can penetrate the cover of the drive cause damage to the device and be thrown out of the device therefore causing injury to uncovered body parts particularly the face or neck I To protect the CD DVD drive and prevent mechanical damage as well as premature wearing o...

Страница 15: ...components that might be damaged by electrostatic discharge ESD are marked with the following label Figure 1 ESD label V CAUTION When you handle components fitted with ESDs you must observe the following points under all circumstances Remove the power plug from the power socket before inserting or removing components containing ESDs You must always discharge static build up e g by touching a groun...

Страница 16: ...t the points marked green touch points Do not touch any exposed pins or conductors on a component Place all components on a static free base I You will find a detailed description of handling ESD components in the relevant European or international standards EN 61340 5 1 ANSI ESD S20 20 ...

Страница 17: ... To replace non hot plug components proceed as follows Ê Shut down the operating system Ê Switch the server off Ê Pull the power plug out of the safety socket 4 1 1 Opening closing the server Figure 2 Removing the server Ê Undo the knurled screws 1 and pull the server carefully out of the rack as far as it will go 2 In most cases it makes sense to remove the server from the rack cabinet 1 1 2 ...

Страница 18: ...efore you remove it I How to remove the server from the rack cabinet is described in the Operating Manual Figure 3 Taking off the housing cover Ê Undo the knurled screw at the back of the device Ê Push the server cover backward 2 a few centimeters using the recessed grips 3 Ê Lift up the housing cover and remove it To close the cover follow the instructions above in reverse order ...

Страница 19: ...e fan modules Figure 4 system fan overview 4 system fan modules consisting of 2 fans each 2 memory fan modules 1 power supply fan module consisting of 2 fans If one fan fails replace this fan to guarantee the required air flow in the system system fans system fans system fans system fans memory fan memory fan power supply fans ...

Страница 20: ... 5 System fans V CAUTION A defective fan module must not be replaced during operation Rotating parts involve an increased risk of injury Make sure that the fan blades have stopped turning before removing the fan module Ê Open the server as described in the section Preparation on page 17 ...

Страница 21: ...ure 6 Removing a system fan module Ê Pull the plug of the defective system fan module out of the fan board 1 Ê Lift the defective system fan module out of the system Ê Insert the new system fan module Ê Connect the plug of the new system fan module with the fan backplane 1 ...

Страница 22: ...of the outward airflow V CAUTION Make sure you install the fan in the correct direction The direction of the outward airflow is indicated on the top of the fan housing and must be the same as that of the other fans Ê Close the server and connect all power plugs for a detailed description see the Options Guide ...

Страница 23: ...ement routines Replacing the fans Memory fans Figure 8 Removing installing memory fans Ê Remove the fan module as described on page 21 removing of a system fan Ê Install the fan module as described on page 21 installing of a system fan ...

Страница 24: ...e fans Replacement routines Power supply fans Figure 9 Installing removing power supply fans Ê Remove the fan module as described on page 21 removing of a system fan Ê Install the fan module as described on page 21 installing of a system fan ...

Страница 25: ...server the ambient temperature is measured on the control panel board If the ambient temperature sensor is defective replace the complete control panel board Ê Open the server as described in the section Preparation on page 17 Figure 10 Opening the maintenance cover of the control panel Ê Undo the screw see figure and lift the maintenance cover carefully to remove the control panel V CAUTION The c...

Страница 26: ...panel board Ê Undo both screws see figure Ê Remove the control panel board Ê Insert the new control panel board Ê Fasten the control panel board with the 2 screws Ê Plug the cable on the control panel board Ê Insert the maintenance cover and fasten it with the screw Ê Close the server and connect all power plugs for a detailed description see the Options Guide ...

Страница 27: ...ng the power supply unit 4 4 Replacing the power supply unit Ê Open the server as described in the section Preparation on page 17 Figure 12 Removing the power supply unit dummy cover Ê Undo both screws see figure and remove the power supply unit dummy cover ...

Страница 28: ...supply cable s connector Ê Pull the internal power supply cable s connector out of the power supply unit and bend it carefully to the side see figure Figure 14 Position of the connectors of the power supply Ê Pull out the connectors of all the cables attached to the power supply unit see 1 6 in the figure above 2 3 1 5 6 4 ...

Страница 29: ...upply unit Figure 15 Opening the cable clamp Ê Open the cable clamp Figure 16 Removing the power supply unit from the housing Ê Pull the power supply unit carefully out of the housing I When doing this ensure that the internal power supply cable see circle is not pinched ...

Страница 30: ...e the housing V CAUTION Push the cables and connectors carefully through the cable ducts inside the housing see figure to avoid damaging them To install the power supply unit follow the above steps in reverse order Ê Close the server and connect all power plugs for a detailed description see the Options Guide ...

Страница 31: ...r power supply cable Ê Open the server as described in the section Preparation on page 17 Ê Remove the power supply unit as described in the section Replacing the power supply unit on page 27 Figure 18 Position of the cable clamps of the internal power supply cable Ê Open the cable clamps and remove the internal power supply cable ...

Страница 32: ...p spring on the underside of the line filter access holes are provided both at the side and on the underside of the server housing Ê Now push the line filter out at the rear through the opening in the housing Ê Push the line filter in at the rear through the opening in the housing Ê Insert the internal power cable into the cable clamp and close the cable clamp Ê Close the server and connect all po...

Страница 33: ...module and fasten it with the screw Ê Plug the I2 C bus cable Ê Close the server and connect all power plugs for a detailed description see the Options Guide I To enable ServerView and ServerStart to identify the system the Chassis ID Prom must be reprogrammed using the Chassis ID Prom tool after the new chassis ID module has been installed You will find this tool on the ServerSupport CD or you ca...

Страница 34: ... 4 7 Replacing the non hot plug hard disk The non hot plug hard disk is accommodated in a sturdy mounting assembly and must be dismounted in order to replace it Figure 21 Mounting assembly with a non hot plug hard disk Ê Open the server as described in the section Preparation on page 17 ...

Страница 35: ...essed to pull it out This is on the underside here and therefore cannot be seen Ê Loosen the hard disk housing s knurled screw 2 Ê Pull the hard disk mounting assembly out Ê Remove the hard disk from the mounting assembly by undoing the four screws see figure 21 on page 34 Ê Install the non hot plug hard disk following the above steps in reverse order Ê Close the server and connect all power plugs...

Страница 36: ...ly Figure 23 Removing the SATA backplane Ê Loosen the knurled screw see figure from the SATA backplane then move the backplane to the direction of the arrow until its holes disengage from the housing stand offs Lift the SATA backplane then set it aside Ê Install the new SATA backplane match its holes with the housing stand offs then move it to the opposite direction to lock I Be careful of the har...

Страница 37: ...s from the fan backplane Figure 24 Removing the fan backplane Ê Loosen the knurled screw see figure from the fan backplane then move the backplane to the direction of the arrow until its holes disengage from the housing stand offs Lift the fan backplane then set it aside Ê Install the new fan backplane match its holes with the housing stand offs then move it to the opposite direction to lock Ê Con...

Страница 38: ...ules the relevant procedure is described in the Options Guide Ê Remove the air duct the heat sink s and processor s the relevant procedure is described in the Options Guide Ê Remove the riser card holders the relevant procedure is described in the Options Guide Ê Remove all cables connected to the system board Figure 25 Positions of the screws on the system board Ê Remove 11 system board screws se...

Страница 39: ...th 11 screws Ê Reconnect all cables I For cabling information see section Cabling on page 44 Ê Reinstall the riser card holders the relevant procedure is described in the Options Guide Ê Reinstall the air duct the heat sink s and processor s the relevant procedure is described in the Options Guide Ê Reinstall the memory modules the relevant procedure is described in the Options Guide Ê Close the s...

Страница 40: ......

Страница 41: ...board layout of the system board is described in the Technical Manual of the system board D2130 5 1 1 Control panel board Part number SNP A3C40066829 Figure 26 Control panel board Connection 1 USB34 connector on system board 2 PANEL1 connector on system board 1 2 ...

Страница 42: ...ector assignment on the SATA backplane Connection 1 Power supply 2 SATA LED controller connector I2C_SATA1 on system board 3 SATA1 connector on system board 4 SATA2 connector on system board 5 SATA HDD1 data and power connector 6 SATA HDD2 data and power connector 7 IDTEMP Combo board SNP A3C40038146 1 2 3 4 5 6 7 ...

Страница 43: ...ngle system fan module for memory modules 3 Double system fan module for CPU2 4 Double system fan module for CPU2 5 Double system fan module for CPU1 6 Double system fan module for CPU1 7 Single system fan module for memory modules 8 PANEL2 connector on system board 9 PSU signal connector from power supply unit 10 Power plug from power supply 11 IDTemp Combo board SNP A3C40038146 1 2 3 4 5 6 7 8 9...

Страница 44: ...50 14G000900800 Fan control cable System board D2130 Fan backplane 6 Mit Lüfter verbunden Fan control cable Fan board Fan backplane 7 Mit Lüfter verbunden Fan control cable Fan board Fan backplane 8 SNP A3C40068545 14G00380170 SATA cable System board D2130 SATA back plane resp SATA HDD 9 SNP A3C40072583 14G003801702 SATA cable System board D2130 SATA back plane resp SATA HDD 10 SNP A3C40068546 14G...

Страница 45: ...able connections of the RX220 hot plug B M C H a r d d i s k 2 H a r d d i s k 1 C D R O M D V D C D R W O p e r a t i n g p a n e l P o w e r s u p p l y u n i t S A T A b a c k p l a n e F a n b a c k p l a n e I D T E M P C o m b o P 5 P 4 P 3 P 1 P 2 S A T A 1 S A T A 2 S A T A 1 S A T A 2 R S B S 2 L P ...

Страница 46: ...e 30 Cable connections of the RX220 non hot plug H a r d d i s k 2 H a r d d i s k 1 C D R O M D V D C D R W O p e r a t i n g p a n e l P o w e r s u p p l y u n i t F a n b a c k p l a n e I D T E M P C o m b o P 5 P 4 P 3 P 1 P 2 S A T A 1 S A T A 2 R S B S 2 L P B M C ...

Страница 47: ...tery exchange 13 M meaning of the symbols 7 N non hot plug hard disk replace 34 notational conventions 7 note about the laser 15 notes on handling CDs 14 P power supply unit dummy cover 27 internal server power supply cable 31 Position of connectors 28 replace 27 R remove housing cover 18 replace chassis ID module 33 fan backplane 37 line filter 32 non hot plug hard disk 34 SATA backplane 36 syste...

Страница 48: ...48 Service Supplement RX220 Index system fans replace 19 T target group 5 ...

Страница 49: ...0 Server System RX220 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 50: ......

Страница 51: ...0 Server System RX220 Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 81730 Munich Germany Fax 49 700 372 00000 email manuals fujitsu siemens com http manuals fujitsu siemens com ...

Страница 52: ......

Страница 53: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Отзывы: