background image

PRIMERGY

PRIMERGY RX200 S2
Serversystem   

Options Guide

Joachim Pichol
Fujitsu Siemens Computers GmbH Paderborn
33094 Paderborn
e-mail: email: [email protected]
Tel.: (0 5251) 8 -148 84
Fax: 0 700 / 372 00001
 
Sprachen:  En          

Edition October 2004

Содержание Primergy RX200 S2

Страница 1: ...X200 S2 Serversystem Options Guide Joachim Pichol Fujitsu Siemens Computers GmbH Paderborn 33094 Paderborn e mail email manuals fujitsu siemens com Tel 05251 8 14884 Fax 0 700 372 00001 Sprachen En Ed...

Страница 2: ...artment Certified documentation according to DIN EN ISO 9001 2000 To ensure a consistently high quality standard and user friendliness this documentation was created to meet the regulations of a quali...

Страница 3: ...Preface Procedure Safety Instructions Preparation Main Memory Processors Accessible Drives Controllers in Non Hot Plug PCI Slots RemoteView Components Completion Continued...

Страница 4: ......

Страница 5: ...Abbreviations Related publications Index...

Страница 6: ......

Страница 7: ...Processors 19 6 1 Installing a second processor 19 6 2 Exchanging the processor 24 6 3 Exchanging the heat sink 27 7 Accessible Drives 29 7 1 Installing the LocalView Module 30 7 2 Installing a CD ROM...

Страница 8: ......

Страница 9: ...on intel based Servers Concept and target groups This Options Guide shows you how you can expand and upgrade the server V Caution The activities described in this manual may only be performed by spec...

Страница 10: ...ServerBooks CD supplied The Ergonomics manual PDF available on the ServerBooks CD supplied I You can order a supplementary ServerBooks CD by sending an e mail to the following address quoting your se...

Страница 11: ...e drives The accessible drives available are a floppy disk drive and a CD ROM DVD drive The drives can be installed in the two top bays The left hand bay is intended for a 3 5 x 0 5 inch floppy drive...

Страница 12: ...2 low profile RSB S2 LP is a PCI board with a completely independent system i e it has its own operating system with Web server and SNMP agents and can optionally be equipped with an external power su...

Страница 13: ...cate names of chapters and terms that should be emphasized text which follows this symbol describes activities that must be performed in the order shown V CAUTION pay particular attention to text mark...

Страница 14: ......

Страница 15: ...y Instructions on page 9ff Make sure that all required manuals see Additional documentation about the server on page 1 are available printing out the PDF files if necessary You will definitely need th...

Страница 16: ......

Страница 17: ...al and any unautho rized openings and improper repairs could expose the user to risks e g electric shock fire hazards and could also damage the equipment Please note that any unauthorized opening of t...

Страница 18: ...t from the mains voltage you must remove the power plug from the power outlet Always connect the device and the attached peripherals to the same power circuit Otherwise you run the risk of losing data...

Страница 19: ...pression Install only system extensions that satisfy the requirements and rules governing safety electromagnetic compatibility and telecommunica tions terminal equipment If you install other extension...

Страница 20: ...symbol a crossed out garbage can The marking also contains the chemical symbol of the heavy metal that determines the classification as a pollutant Cd Cadmium Hg Mercury Pb Lead Notes on handling CDs...

Страница 21: ...LASER CLASS 1 Modules with electrostatic sensitive devices Electrostatic sensitive components are identified by the following sticker Figure 1 ESD label V CAUTION When you handle components fitted wi...

Страница 22: ...e points marked green touch points Do not touch any exposed pins or conductors on a component Place all components on a static free base I You will find a detailed description of handling ESD componen...

Страница 23: ...er Safety Instructions on page 9ff 4 1 Opening the server Exit all applications and shut down the server correctly Press the on off button Unplug the power plugs Figure 2 Removing the server Undo the...

Страница 24: ...he rack Before you remove the server from the rack you must therefore unplug all cables connected to the server from their sockets I How to remove the server from the rack is described in the operatin...

Страница 25: ...t memory access with two way interleaving 5 1 Installation rules V CAUTION Memory modules have to be installed in pairs Each memory bank must always be fully equipped with the same type of modules The...

Страница 26: ...ejector tabs on each side of the slot outward 1 This levers an installed memory module out of its slot Remove the memory module from the slot 2 Figure 5 Installing a memory module Carefully press the...

Страница 27: ...tive wrapper or out of a socket place it on an insulated antistatic surface with the smooth side down Never slide a processor over a surface 6 1 Installing a second processor The system board can be u...

Страница 28: ...20 OptionsGuide Installing a second processor Processors Removing the ventilation duct Figure 6 Removal of the ventilation duct Lift off the ventilation duct upwards...

Страница 29: ...ocessor Removing the heat sink dummy Figure 7 Removing the heat sink dummy Remove the heat sink dummy Installing the processor Figure 8 Opening the socket lever Release the socket lever by pressing it...

Страница 30: ...y pushing it downwards 1 V CAUTION The processor can only be installed in one direction Pay attention to the marking on one of the corners for the correct alignment see figure To avoid damaging the pi...

Страница 31: ...ver Attach the heat sink with four screws Tighten the screws in diagonally opposite sequence 2 V CAUTION Never install a processor without a heat sink The processor is likely to overheat which may cau...

Страница 32: ...aration on page 15f Remove the ventilation duct see page 20 Figure 11 Removing the processor heat sink Remove the four screws of the heat sink in diagonally opposite sequence see figure Turn the heat...

Страница 33: ...talling the new processor Position the new processor above the socket and press it carefully into the socket 1 V CAUTION The processor can only be installed in one direction Pay attention to the marki...

Страница 34: ...heat sink on the processor such that the side labeled FRONT is facing the front of the server see page 23 Attach the heat sink with four screws Tighten the screws in diagonally opposite sequence see p...

Страница 35: ...fully back and forth to loosen it Then lift it out to remove it Clean the surface of the processor with a lint free cloth Fit the heat sink on the processor such that the side labeled FRONT is facing...

Страница 36: ......

Страница 37: ...a total of two slots for accessible drives Available are a floppy disk drive and a CD ROM DVD drive Instead of the floppy drive a LocalView module can be installed The drives can be installed into th...

Страница 38: ...splay panel These status messages provide system information and warnings of hardware errors e g fan failure CPU overvoltage etc The LocalView module can be pulled out like a drawer You can also angle...

Страница 39: ...cooling require ments and fire protection measures Push the LocalView module into its bay until it engages Figure 15 Connecting the LocalView module Connect the CN6 plug of the SCSI fan board see figu...

Страница 40: ...If the bay is empty a dummy cover will have been fitted Removing the dummy cover Figure 16 Dummy cover Remove the dummy cover with a screwdriver V CAUTION Keep the dummy cover for future use If you re...

Страница 41: ...lling a CD ROM DVD drive Installing a CD ROM DVD drive Figure 17 Mounting the drive in its frame Insert the CD ROM DVD drive in its frame and secure it with four screws Push the CD ROM DVD drive into...

Страница 42: ...cessible Drives Figure 18 Installing the CD ROM DVD drive Plug the data cable 1 and the power cable 2 into the CD ROM DVD drive Close the server plug in the power plugs and switch on the server as des...

Страница 43: ...If the bay is empty a dummy cover will have been fitted Removing the dummy cover Figure 19 Dummy cover Remove the dummy cover with a screwdriver V CAUTION Keep the dummy cover for future use If you r...

Страница 44: ...sible Drives Removing installing a floppy disk drive Figure 20 Mounting the drive in its frame Insert the floppy disk drive in its frame and secure it with two screws Push the floppy disk drive in its...

Страница 45: ...e Figure 21 Connecting the data cable Remove the capton foil from the data cable and connect the cable to the rear of the floppy drive see figure Close the server plug in the power plugs and switch on...

Страница 46: ......

Страница 47: ...ch are not hot pluggable you must proceed as follows Shut down the operating system Switch off the server and Unplug the power plugs The system board contains two PCI X slots which can only be used vi...

Страница 48: ...igure Pull out the riser card holder upwards Installing a PCI board Please read the documentation supplied with the PCI board Plug any necessary cables into the PCI board Remove the slot cover from th...

Страница 49: ...slot cover fits into the appropriate recess If necessary plug in the cables on the board and other components Reinstalling the riser card holder Plug the riser card holder into the system board Attac...

Страница 50: ......

Страница 51: ...eb server and SNMP agent and can be driven by an external power supply The RSB S2 LP should preferably be installed in the low profile PCI slot but can also be installed in the full height slot It is...

Страница 52: ...and fire protection measures Install the RSB S2 LP in the low profile PCI slot 2 of the riser card The procedure is described in the section Installing controllers on page 40 Plug the power cable into...

Страница 53: ...25 Installing the cover Position the cover in such a way that the rear edge protrudes 3 4 cm from the housing Push the cover to the front as far as it will go Attach the cover with the knurled screw...

Страница 54: ...rack 1 I After you have inserted the server you should pull it out again as far as it will go and then push it back in This ensures that the server runs cleanly on the telescopic rails Fasten the ser...

Страница 55: ...c Server Reconfiguration and Restart BIOS Basic Input Output System BMC Baseboard Management Controller CC Cache Coherency CD Compact Disk CD ROM Compact Disk Read Only Memory CHS Cylinder Head Sector...

Страница 56: ...Interface ECC Error Checking and Correcting ECP Extended Capabilities Port EEPROM Electrically Erasable Programmable Read Only Memory EMC ElectroMagnetic Compatibility EMP Emergency Management Port EP...

Страница 57: ...Disk Drive HSC Hot Swap Controller I C Inter Integrated Circuit I O Input Output ICM Intelligent Chassis Management ID Identification IDE Integrated Drive Electronics IRQ Interrupt Request Line LAN Lo...

Страница 58: ...Non Maskable Interrupt NVRAM Non Volatile Random Access Memory OS Operating System PCI Peripheral Component Interconnect PDA Prefailure Detection and Analysis POST Power ON Self Test RAID Redundant Ar...

Страница 59: ...Error SCA Single Connector Attachment SCSI Small Computer System Interface SDR Sensor Data Record SDRAM Synchronous Dynamic Random Access Memory SEL System Event Log SMI System Management Interrupt SS...

Страница 60: ......

Страница 61: ...line documentation available in the Internet can be found via the URL http manuals fujitsu siemens com choose intel based servers 1 Safety 2 Warranty 3 19 inch rack Technical Manual 4 DataCenter Rack...

Страница 62: ...m Board D1790 Technical Manual 15 BIOS Setup Reference Manual 16 Integrated Mirroring User s Guide 17 Global Array Manager Client Software User s Guide 18 Global Array Manager Server Software User s G...

Страница 63: ...nge 27 installation 23 removing the dummy 21 I information material 2 installation CD ROM DVD drive 33 cover 45 RemoteView Service Board S2 LP 43 riser card holder 41 ventilation duct 23 L light emitt...

Страница 64: ...r card holder 40 ventilation duct 20 riser card holder installation 41 removal 40 T target group 1 U upgrade CD ROM DVD drive 32 controller 40 floppy disk drive 35 LocalView module 30 main memory 18 P...

Страница 65: ...0 S2 Serversystem Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany Fax 0 700 372 00001 email manuals fujitsu siemens com http man...

Страница 66: ......

Страница 67: ...0 S2 Serversystem Comments Suggestions Corrections Submitted by Fujitsu Siemens Computers GmbH User Documentation 33094 Paderborn Germany Fax 0 700 372 00001 email manuals fujitsu siemens com http man...

Страница 68: ......

Страница 69: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu bergegangen Diese neue Tochte...