10
Min
Max
CONTROLS
SPS aboveground Salt Generators have an Auto control system with a very simple
operation.
• DESIRED LEVEL:
There are 10 LEDS, each LED is 10%, chose the “desired
level %” by pressing Min to decrease or Max to increase. The SPS will produce
chlorine according to the “Desired Level %” adjustment setting for the entire
filter cycle.
• MAX:
Press Max to increase the level up to 100%, when you have an abnormally
high bather load, heavy rainfall, cloudy water conditions, or any other condition which
requires that a large amount of purification be introduced, Push Max until all
10 LEDS ARE ON. This electronically “Max chlorinates” (shocks) the water for 24
hours (filter pump must be on during this time) or until the power has been turned off,
whichever comes first.
At the end of the Max chlorination period, be sure to push
Min to decrease level back to the desired level position
.
• MIN:
Press Min to decrease the desired level. When all of the 10 LEDs are OFF,
it will prevent the SPS from energizing the electrolytic cell. In this position there is
no chlorine generation.
• LOW SALT:
When flashing, the salt level is low (below 2500 ppm) and SPS is
generating at low efficiency. When illuminated steady, the salt level is too low and
SPS has shut down.
NOTE:
In times of servicing, the OFF switch is not to be used.
To service the SPS, turn power off at circuit breaker.