Specifications
3.4. Reinforce splice point by mechanical clamp
3.4.1 Set mechanical clamp body on assembly tool
3.4.2. Remove spliced fiber
3.4.3. Set spliced fiber on assembly tool
3.4.4. Assemble mechanical clamp
3.5. Housing assembly
3.5.1 Removing the connector form assembly tool
3.5.2 Assemble boot unit and housing assembly
Grip ribbon fiber and connector
holder , then remove spliced fiber
Insert boot unit into pin clamp
Open cover of connector holder
Set mechanical clamp body
on assembly tool
Note:
Ensure there is no gap
at this point
Set spliced fiber on
assembly tool
Note:
Shut the hinge while pulling the fiber.
Set mechanical clamp cover in the
hinge segment of the assembly tool.
Shut mechanical clamp cover
by
mechanical sleeve press
Remove connector holder from assembly tool while releasing the hinge
Remove connector from connector holder.
Insert boot unit into housing
assembly and ensure latch is
secured
Note:
Insert projection of pin
clamp in spring.
Completed!
Peel off the protection film of
mechanical clamp body.
Peel off the protection film of
mechanical clamp cover.