AC Adapter
LED
Turning ON
Press
Press
key until
green
LED turns on.
Turning OFF
key until
red
LED turns on.
ESCAPE Key
MENU Key
ENTER Key
·
Return to previous screen
·
Enter of value
·
Open Main Menu
·
Go to next page
UP/DOWN Key
·
Move cursor
·
Change value
·
Input power : DC12V
·
Use only supplied DC power cord.
·
Input power : AC100-240V, 50-60Hz
·
Use only supplied AC power cord.
·
Connect to ground with ground terminal
of AC power cord.
·
When using a AC power generator,
check output voltage periodically
with a circuit tester.
AC operation
DC operation
AC Input
DC Input
Battery Pack
How to recharge Battery Pack
ADC-18
BTR-09
DCC-18
Rechage by DC is also possible
Note
How to use Keypad
Power Supply
AC cord
Connect AC adapter (ADC-18) and battery pack (BTR-09)
with battery recharge cord (DCC-18).
Do not stack battery pack on top of AC adapter while
recharging.
Recharging temperature : 0 ~ 40°C (32 ~ 104°F)
How to check remaining capacity
Confirm power saving function is working when using battery pack
ON/OFF Key
X/Y Key
ARC Key
·
Power ON/OFF
·
Execute Splice
RESET Key
·
Stop and back
to Ready
·
Switch X/Y images
SET Key
HEAT Key
Open/Close Key
·
Operation of a
Wind Protector
·
Arc
·
Heat Cancel
·
Operation of a lid
Fusion Splicer 19R+/70R+
Quick Reference Guide
♦
♦
♦
V-grooves
•
Clean bottom of V-groove with a thin cotton
swab moistened with alcohol.
•
Remove excess alcohol from V-grooves
with a clean dry swab.
•
Use a cleaved fiber end-face to dislodge.
Fiber Clamp Chips Fiber Cleaver
Objective Lens
When lens is dirty, clean it.
•
Clean rubber pads.
•
Clean rubber anvil.
•
Clean blade.
Caution of cleaning
•
Do not contact the electrode tips.
•
Use only 99% or better purity of alcohol.
Electrodes
•
When “Replace electrodes” message appears, or when the tip is damaged, replace
electrodes.
•
Execute [Replace Electrodes] in Maintenance Menu.
•
Exchange for a new electrode the old electrode currently attached to equipment.
Use attached screw driver (SD-01).
Loosen screws
Tighten screws
Remove the old electrode
Install new electrode
Electrode holder
Remove the electrode cover
Place the electrode cover
•
Load prepared fibers onto the splicer.
•
Execute [Stabilized Electrodes]
•
[Arc Calibration] is executed.
Replace Electrodes
Cleaning before Splice Operation
Fusion Splicer 19R+/70R+
Quick Reference Guide