FOR YOUR SAFETY USE

1:3.1/12.5-400mm 1/1.8” C-Mount

Before using this product, please read this operation manual carefully, and keep the manual handy for future use.

WARNING and 

CAUTION:

CAUTION

WARNING

Make sure all parts are mounted and fastened securely.

Do not use the lens to look at the sun or other powerful light sources. Doing so could cause eye injury.

CAUTION

Before supplying power to the lens, make sure all the parts are connected correctly.

Notices

Do not use this product for purposes beyond the uses mentioned in this manual.

The lens and its accessories are extremely precise instruments. Never subject them to strong impact.

The lens may fog when transported from a cool place to one of high temperature and humidity. 
To  avoid  such  fogging,  before  moving  the  lens  allow  it  to  adjust  to  the  ambient  temperature  of  the 
environment of use.

GENERAL DESCRIPTION

ATTACHMENT TO THE CAMERA

1)

Power Supply Connector

 (OMRON XW4B-02B1-H1)

2)

Iris Connector

 (EIAJ RC5204

 

compliant, jack side

3)

Analog Control Connector

(OMRON XG4A-1635)

4)

ADJUSTMENT

Application

1/1.8" Format Day/Night Camera 

Focal Length

12.5 mm ~ 400 mm 

Zoom Ratio

32× 

Iris Range

F3.1 ~ F16

WIDE  30.90°× 23.54°
TELE    1.03°×  0.77°
Aspect Ratio : 4:3

Field Angle (H×V)

Focus Range

∞ ~ 3 m  (from front of lens)

Built-In Filter

Visible Light Cut Filter ※

Mount

C-Mount

Filter Screw Size

M82×0.75 mm

Operating Temperature -10゜C ~ +50゜C
Storage Temperature

-20゜C ~ +60゜C

Dimensions(H×V×D)

114mm×108mm×258mm

Mass

2.8 kg Approx

D-sub 9pin Connector(Female)

Protocol

C10 or Pelco-D

16-pin Flat Cable Connector

DC 6/9/12V,±6/±9/±12V

Focus

DC 6/9/12V,±6/±9/±12V

Optical Filter

DC 5~12V

Potentiometer

5±0.5V,3.3±0.3V

4-pin Iris Cable (EIAJ-compliant)

Control Mode

DC Iris Control
Video Iris Control
Manual Remote Control

Power Supply Voltage

DC 12V

Consumption

Approx. 360 mA (operating at maximum)
Approx. 70 mA (at rest)

Serial Control

Connector

Analog Control

Connector
Control Voltage
Zoom

Iris Control

Connector

This lens is designed for indoor use. When using the lens outdoors, always take proper measures including 
the use of a protective cover.

SPECIFICATIONS

(1) 

Optical and Mechanical

(

2

Electrical

CONNECTION INTERFACE

② ③ ④ ⑤

⑥ ⑦ ⑧ ⑨

CONTROL SWITCH SETTINGS

(1)

 Control mode selection switch settings

(2)

 Iris mode selection switch settings

(3)

 Standard power supply selection switch settings

(4)

(5)

Switch lens control between serial mode and 
analog mode. 

Set iris control to DC iris mode or video iris 
mode.

(1)

 Adjustment of Video Iris
Adjust the video iris LEVEL and ALC using the 
respective control trimmers.

(2)

 

Adjustment of Flange Focal Length

If the camera does not have flange focal length adjustment capability, you can adjust the flange focal length 
on the lens side.

Loosen the three screws 

(1.5mm) 

for securing the flange focal length.

Tighten the fixing screws to secure the flange focal length.

See the documentation for your PC or other control device.

F

D

32

x12.5

SR4A-CV1

See the detailed user manual for more information. 

The detailed user manual can be downloaded from our website.

URL :  

https://fm.fujifilm.jp/form/pub/cctvlens/download-

e

※ 

Combining the visible light cut filter with a

 

n

ear-

infrared camera is effective for removing dense fog.

WARNING

This section explains important notices about how to use this product safely. Before using this product, be sure 
to read this section carefully and follow the instructions.  
The following signs in the text indicate

: Indicates the possibility of causing death or serious injury if the product is misused.

: Indicates the possibility of causing injury or substantial damage if the product is misused.

The FUJINON FD32x12.5

 

lens is a high-performance, fully HD-compatible zoom lens for 1/1.8" format day/night 

cameras.

Do not allow the inside of the product to become wet or moist, as it may cause fire or electric shock. If this 
occurs, immediately shut off the power supplied to the lens.

When using a heavy camera, be sure to secure the camera and lens securely to a tripod using the tripod 
mounts on both the camera and the lens.  Using only the tripod mount on the lens could damage the lens 
due to the weight of the camera, or the camera could separate from the mount and fall, causing serious 

Do not leave or store the lens in direct sunlight, as the lens may focus light on a nearby object and cause a fire.

Do not aim the lens toward the sun, as the sunlight may focus on the interior of the lens and damage the parts.

Take care when carrying the lens, as dropping it may cause injury.

Make sure the power supplied to the lens is of the rated input voltage; otherwise, a fire, electrical shock or 
product damage may occur.

In order to install or release a cable, be sure to hold the joint part.  Do not damage the cable by gripping.
It may cause fire or electric shock.

If any sorts of incidents such as unusual smoke, noise, smell or obstacles are found, shut off the power 
supplied to the lens and detach the lens from the camera immediately.  Please notify the sales agent from 
which you purchased the product.

Do not remodel the instrument: it may impair the functions of product or cause electric shock.

Press the threaded portion of the camera mount against the threaded portion of the lens mount, and slowly 
rotate the camera clockwise to screw it securely into the lens.

For more information on the arrangement of connectors and switches, see the illustration 

page

.

RS-232C Connector (Female)

Same specifications as a typical D-sub 9-pin connector (female).

※Always use the internal power supply for serial control.

Select the external or internal power supply for 
the potentiometer.

Serial control mode selection switch 
settings

Analog control mode selection switch 
settings

Insert  an  Allen  wrench  of  the  appropriate  size

  (2mm)

  into  the  hexagonal  hole 

for flange focal length adjustment, and then turn the adjustment hole to adjust 
the flange focal length.

Design and specifications are subject to change without notice.

damage or an accident.

Bit

1

2-3

4-7

8

Mode

↓:C10
↑:Pelco-D

Pelco-D
Baud rate *1

Pelco-D
Address *2

Pelco-D

Runaway 

Protect

SW Position

Mode

Serial

Analog

SW Position

Mode

DC Iris

Video Iris

SW Position

Mode

Internal

External

*

1: 00=2400,10=4800,01=9600,11=115200bps

*2: 0000=Address 1 ~ 1111=Address 16

Bit

1

2-3

4-7

Mode

Reserved

Trimmer Name

Function

Adjustment Direction

Brighter

H(clockwise)

LEVEL

Darker

L(counter-clockwise)

Peak

Pk(clockwise)

ALC

Average

Av(counter-clockwise)

↓:Independent
↑:Common

00/01:12V/±12V
  10   :  9V/±9V
  11   :  6V/±6V

① 

Power

 (DC12V)

 

GND 

DC Iris

Video Iris

Brake (-)

- 

Brake (+)

- 

Drive (+)

Video Signal

Drive (-)

GND 

Pin

Common Mode

Independent Mode

1

Filter

2

GND

+Wide

3

Zoom

-Telephoto

4

Common

+Far

5

Focus

-Near

6

Common

7

Potentiometer Power Supply (Input)

8

Potentiometer GND

9

Focus Potentiometer Output

10

Zoom Potentiometer Output

11

GND

12

Iris Manual Remote (Input)

13-16 No connection

↑ Wide Angle
↓ Telephoto

↑ Far
↓ Near

Отзывы: