8-22
8.2 Scanner Section
4. Remove the sensor from the bracket by releasing
its locking tabs.
Installation
Installation is essentially in the reverse order of
removal.
After installation perform the following adjustments.
1) Menu 0346 “Optical Magnification Calibration”
2) Menu 0347 “Focus Calibration”
3) Menu 0321 “Focus Position Adjustment”
Removal
1. Remove the CPZ23 circuit board box cover
2. Disconnect all connectors from the CPZ23 circuit
board.
3. Install the fixing bracket to conjugate length
variable section
.
4. Cut the cord tie and open the two harness clamps.
5. Loosen the two screws, remove the other two
screws and then the CPZ23 circuit board box.
Z
2
132
Locking Tabs
Bracket
Conjugate Length Variable
Section Home Position
Sensor (D201)
8.2.16
Conjugate Length Variable Gear/Rack Replacement
Z
2
150
Screws (2) (Loosen)
CPZ23 Circuit Board Box
Screws (2) (Remove)
Harness Clamps (4)
Cord Tie