FUJIDENZO IWAR120G Скачать руководство пользователя страница 1

Inverter Window Type Air Conditioner  

Thank you for choosing our product.

If you have lost the Owner’s Manual, please contact the local agent or visit

www.exatech.com.ph or send an email to [email protected] for a soft 

copy of the owner's manual.

For proper operation, please read and keep this manual carefully. 

AIR CONDITIONER

Model: 

IWAR90G   IWAR120G 

Содержание IWAR120G

Страница 1: ... you have lost the Owner s Manual please contact the local agent or visit www exatech com ph or send an email to service exatech com ph for a soft copy of the owner s manual For proper operation please read and keep this manual carefully AIR CONDITIONER Model IWAR90G IWAR120G ...

Страница 2: ......

Страница 3: ...images used in this manual may have a slight difference from the actual product s appearance please check the actual product for reference 1 Function 3 Precautions 2 Power requirement 4 Installation 5 Notes for installation 8 Operation procedure 9 Air direction adjustment 9 10 Remote control panel Remote control operation procedure 15 Operation Tips 16 Care and maintenance Caution 17 Care and main...

Страница 4: ...eatures which lead to a really high WARNING Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacture Should repair be necessary contact your nearest authorized Service Centre The appliance shall be stored in a room without continuously operating ignition electric heater Do not pierce or burn than 4m 2 s instructions only Be aware that refrig...

Страница 5: ...t is 7 C 43 C Precautions This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Childre...

Страница 6: ...Winter Wind direction Summer Cooling in summer Exchange fresh air Heating in winter Only for heat unit Dehumidifying in rainy or humid season In hot summer Air conditioner can cool down theroom air by transferring heat out Without reducing the room temp air conditioner can dehumidify and make the room air dry and comfortable Dry In cold winter Air conditioner can heat up room air Open storm door t...

Страница 7: ...g system along with other electrical components To ensure the reliable earthing please do not connect earth wire to the following places Earth wire Water pipe The ground must be connected Special socket must be used Furthermore the socket and wiring must conform to the wiring regulations And the earthing method must be reliable protection switch of enough power capacity and air switch with enough ...

Страница 8: ...before use Avoid other heat sources or direct sun light Avoid a place where is easy for children to touch Don t use the unit in the immediate surrondings of a laundry a bath a shower or a swimming pool For window type air conditioner with remote control do not install in a location where is strong electromagnetic disturbance you should contact the seller in advance to avoid the malfunction in use ...

Страница 9: ...ration 6 10mm Horizontal line Installation assistance Use iron support The installation hole should be stro ng enough to support the air condit ioner If it cannot iron support has to be used outdoors Iron support sho Use sunshade board Air conditioner should avoid anything to be dropped into it and avoid direct sunshine If there is no cover on it you should contact the seller for inst alling the s...

Страница 10: ...rom the cabinet 2 Install the drain pan to the corner of the cabinet with 2 screws 3 Connect the drain hose to the outlet on the drain pan bottom 4 Slide the chassis into its original place in the cabinet To get the maximum cooling efficiency the air conditioner is designed to splash the condensation water on the condenser coil If the splashing sound annoy you you can remove the rubber plug from t...

Страница 11: ...pport Must connect with ground reliably The exclusive circuit must be used But removable socket can t be used because poor contact of it can cause over heat Make sure to pull the power cord with care and leakage current is less than 30mA Connecting method between air conditioners and power cord and intercon necting method of each individual element with one another should accord with wiring diagra...

Страница 12: ...ing the vane to discharge the air upwards downwards or straight out Remote control panel Air inlet louver Cabinet Front intake grille behind the front intake grille Front Panel Image this is just for reference please check the actual unit ...

Страница 13: ...ton MODE button button FAN button SWING button SLEEP button TIMER button Timer on Timer off Sending signal swing operation sleep operation lock set speed Set time Set temperature heat operation fan operation dry operation cool operation auto operation Remote control operation procedure 2 1 3 4 5 6 7 ...

Страница 14: ...cool mode air conditioner will operate under cool mode Then press or button to adjust set temperature Press FAN button to adjust fan speed When selecting dry mode air conditioner will operate at low fan speed under dry mode In dry mode fan speed can t be adjusted When selecting fan mode air conditioner will operate in fan mode only Then press FAN button to adjust fan speed When selecting heat mode...

Страница 15: ...als to mid fan speed When unit is on press this button to set Timer Off T OFF and H icon will be blinking Within 5s press or button to adjust the time for Timer Off Pressing or button once will increase or decrease the time by 0 5h Hold or button for 2s time will change quickly Release the button after your required set time is reached Then press TIMER button to confirm it T OFF and H icon will st...

Страница 16: ... operate the remote controller remote controller won t send signal Child lock function Temperature display switchover function Under OFF status press button and MODE button simultaneously can switch between C and F Operation guide 1 After plugging in the power cord to the power outlet press ON OFF button on remote controller to turn on the air conditioner 2 Press MODE button to select your require...

Страница 17: ...install 2 Replace with two 7 AAA 1 5V dry batteries Make sure positions for pole and pole are correct 3 Reinstall batteries box cover The distance between signal sender and receiving window should be no more than 8m and there should be no obstacles between them conditioner when using the remote controller Replace new batteries of the same model when replacement is required When you don t use remot...

Страница 18: ...ess the keypad to decrease the set operating temperature of the unit The temperature seting range is from 16 30 MODE BUTTON Select the operation mode AUTO HEAT COOL FAN DRY for reverse cycle model or AUTO COOL FAN DRY for cooling only model 5 SIGNAL RECEIVER 6 SWING BUTTON Activate the automatic air swing function 7 FILTER BUTTON This feature is a reminder to clean the Air Filter See Care and Clea...

Страница 19: ...ine enter the room directly when the air co ndition is in operation Keep the room temp uniform Adjust the vertical and horizo a uniform temperature in the room Air can t be discharged to the direction of air in Make sure that the doors and windows are tightly closed Avoid opening doors and wi ndows as much as possible to keep air conditioning in the room duce dehumidifying effects once every two w...

Страница 20: ...es in the vicinity The air co nditioner s plastic parts will melt if exposed to excessive heat Avoid exposing the body dire ctly to a continuous unidirect This is not recommended for health reason Do not pull out the power cord Damage to the cord may result in serious electric shocks Do not use the air conditioner for other purposes except for cooling the room Do not use the air conditioner for ot...

Страница 21: ...Always wait at least 3 minutes Please notice that the unit is filled with flammable gas R32 Inappropriate treatment of the unit involves the risk of severe damages of people and material Details to this refrigerant are found in chapter refrigerant Appliance shall be installed operated andstored in a room with a floor area larger than 4m2 ...

Страница 22: ...rty use a mild household detergent in the wash water Let the filter dry thoroughly before reinstalling it If necessary please ask the professional personnel to clean it 2 Use soft cloth when cleaning cabinet If the cabinet is very dirty dip cloth into warm water below 40 C dry the cloth and then rub off the dirt 3 Don t use gas benzene solvent wash chemical solvent etc for cleaning Plug out only a...

Страница 23: ...ode operation sometimes unit this is because the room humid air has been cooling rapidly The unit is normal while the indoor out let is sending out some odor because the inlet air may be mixed with the sm ell of furniture and smoke the air conditioner unit For a noise that sounds like a shower This is the sound of the dehumidifying water being processed inside the air conditioner unit iency is not...

Страница 24: ...ith it H4 Please contact professional person to deal with it E4 Please contact professional person to deal with it H3 Please contact professional person to deal with it L9 Please contact professional person to deal with it H5 Please contact professional person to deal with it PL Please contact professional person to deal with it PH Please contact professional person to deal with it HC Please conta...

Страница 25: ... status should be kept during the operation process area warning board should be hanged 4 Check whether the appliance mark is in good condition Replace the vague or damaged warning mark Installation notes table Minimum room area m2 2 The air conditioner must be installed in a room that is larger than the minimum room area The minimum room area is shown on the nameplate or following table 3 Leak te...

Страница 26: ...g the refrigerant 1 Use the refrigerant filling appliances specialized for R32 Make sure that differ ent kinds of refrigerant won t contaminate with each other 2 The refrigerant tank should be kept upright at the time of filling refrigerant 3 Stick the label on the system after filling is finished or haven t finished 4 Don t overfilling 5 After filling is finished please do the leakage detection b...

Страница 27: ......

Страница 28: ...20653 EXCELLENCE APPLIANCE TECHONOLOGIES INC Add EXATECH Bldg 56 Cordillera St cor E Rodriguez Sr Ave Quezon City Philippines Tel 632 230 1555 Fax 632 230 1510 E mail service exatech com ph www exatech com ph ...