Premium DC Inverter Series Cassette Type Unit
6
Note:
There will be large amount of greasy dirt accumulated on the fan, heat exchanger
and water pump located in the dinning room and kitchen, which would reduce the
capacity of the heater exchanger, lead to leakage and abnormal operation of the water
pump.
Fig. 3.1
Table 3.3
Models
H(mm)
255
260
340
320
320
3.2.2 Outdoor Unit
WARNING!
①
. Install the unit where it will not be tilted by more than 5°.
②
. During installation, if the outdoor unit has to be exposed to strong wind, it must be fixed securely.
If possible, do not install the unit where it will be exposed to direct sunlight. (If
necessary, install a blind that does not interfere with the air flow.)
(1). Install the outdoor unit in a place where it will be free from being dirty or getting
wet by rain as much as possible.
(2). Install the outdoor unit where it is convenient to connect with the indoor unit.
(3). Install the outdoor unit where the condensate water can be drained out freely
during heating operation.
(4). Do not place animals and plants in the path of the warm air.
(5). Take the air conditioner weight into account and select a place where noise
FIC360G IN
FIC180G IN
FIC240G IN
FIC480G IN
FIC600G IN