Premium DC Inverter Series Cassette Type Unit
32
29
P5
Over-current protection
30
P6
Communication error between main control and
drive
31
P7
Drive module sensor error
32
P8
Drive module over temperature protection
33
P9
Zero passage protection
34
PA
AC current protection
35
Pc
Drive current error
36
Pd
Sensor connecting protection
37
PE
Temperature drift protection
38
PL
Bus low voltage protection
39
PH
Bus high voltage protection
40
PU
Charge loop error
41
PP
Input voltage abnormality
42
ee
Drive memory chip error
43
C4
Outdoor unit capacity code error
44
C5
Indoor unit capacity code error
Note:
When the unit is connected with the wired controller, the error code will be
simultaneously shown on it.
(2). Instructions to the Error Indicating Lamps on the Panel of the Cassette Type Unit.
Fig.6.1
1). Power and ON/OFF Indicating Lamp:
It goes red when the unit is powered on while it goes white when the unit is started.
2). Timer Indicating Lamp:
It goes on when the timer is set and goes off when it is not. Its display is in yellow.