Fuji Spray soloTAN 4000 T-PRO Скачать руководство пользователя страница 25

24

Fuji Spray® 2 Year Limited Warranty

Fuji Industrial Spray Equipment Ltd. (“Fuji”) provides a 2 year limited 

warranty on the product to the original purchaser effective from the 

date of purchase against defects in materials and workmanship.

The warranty does not cover damage or defects arising as a result of 

abuse, misuse, accident, negligence, malfunction, corrosion, normal 

wear and tear, inadequate or lack of spray gun or other aspects of 

maintenance of the product, damage arising from improper assembly, 

installation or operation, damage arising from the product being 

used with parts that are not genuine Fuji Spray® parts, or damage 

arising from the product being used for a purpose other than that for 

which it was designed or intended. The warranty is void if repairs to 

the product are made or attempted by anyone other than Fuji or its 

authorized agent, or if any modifications to the product are made or 

attempted.

Purchasers located in North America must obtain a Return Material 

Authorization number by calling Fuji at 1-800-650-0930 before 

returning the product to Fuji or its designated representative.

Purchasers located outside North America must contact the vendor 

from which they purchased the product. In all instances purchasers 

must return the product together with proof of purchase and with 

shipping prepaid. For valid warranty claims the product will be 

returned to the purchaser with shipping prepaid.

This is the only warranty provided by Fuji with respect to the product 

and is in lieu of any other warranties, express or implied, including 

but not limited to any warranty of merchantability or fitness for a 

particular purpose. Fuji’s sole obligation under this warranty shall, 

at its option, be to either repair or replace a product determined 

by Fuji to be defective. In no event shall Fuji be liable for loss of 

profits, incidental or consequential damages, injury to any person 

or property, or any other damages of whatsoever nature.

Содержание soloTAN 4000 T-PRO

Страница 1: ...USER MANUAL soloTAN Series studioTAN Series formerly miniTAN salonTAN Series...

Страница 2: ...etails 2 Safety Precautions 3 5 Getting Started 6 7 Parts Diagram 8 11 Spray Patterns 12 13 Spraying Techniques 14 Cleaning and Maintenance 15 19 Troubleshooting 20 23 Warranty Information 24 CE Decla...

Страница 3: ...r as soon as the Turbine is turned on whether you engage the Trigger or not The 4000 T PRO GRAVITY FEED SYSTEM is packaged with 1 Turbine soloTAN studioTAN or salonTAN with Power Cord 2 Air Hose 3 T P...

Страница 4: ...be 220 240v Check the label on the base of the turbine to ensure your unit is at the correct voltage for your location SAFETY PRECAUTIONS ELECTRIC SHOCK HAZARD Improper connection of the equipment gro...

Страница 5: ...nd working Turn off and disconnect power cord before servicing equipment Ensure ground prongs are intact on sprayer and extension cords Never use 1 1 1 trichloroethane methylene chloride other halogen...

Страница 6: ...pull or lift the equipment Do not cover turbine case as this will restrict air to the intake and result to overheating and premature failure of the motor Do not carry turbine while spraying Check the...

Страница 7: ...designed and built with a Breaker Switch This essential component will switch the turbine off in the event that there is overheating or electrical malfunction To avoid any overheating ALWAYS ensure t...

Страница 8: ...the Hose Connector 11 base of the Applicator s Handle over the shaft of the Gun Holder shown in above illustration Please ensure it is fully set down to the base of the shaft The Applicator will now s...

Страница 9: ...8 T PRO APPLICATOR T PRO APPLICATOR...

Страница 10: ...11 5229 Hose Connector 12 5209 Needle Packing 13 5210 Needle Packing Nut 14 5211 Fluid Coupler 4000 T PRO 15 5208 Fluid Coupler 4200 T PRO 16 8088 Cup Lid 17 8181ST Gasket 18 8245T 3oz Teflon Gravity...

Страница 11: ...10 TAN7350 APPLICATOR TAN7350 APPLICATOR...

Страница 12: ...ssembly 9 2309 Needle Spring 10 2310 Handle 11 2311 Hose Connector 12 2312 Needle Packing 13 2313 Needle Packing Nut 14 2330 Trigger Pin 15 2315 Trigger 16 2316 Fluid Coupler 17 9823DB Cup Assembly 18...

Страница 13: ...tight Do not over tighten On the 4000 and 4200 T PRO Applicators the Fan Pattern Control 10 is located on the front right side of the Applicator if looking from the front To produce a wide fan patter...

Страница 14: ...l Knob Setting the Aircap in a vertical position diagram B on page 12 produces a horizontal spray pattern This pattern is the most useful and simplest pattern shape for spray tanning We recommend that...

Страница 15: ...e spray pattern rotate the position of the Aircap rather than tilting the Applicator to its side CORRECT INCORRECT Start moving the Applicator in the direction you are going to spray before pressing t...

Страница 16: ...removing it turn the Fluid Knob 7 counter clockwise this will allow you to pull back the Trigger all the way 5 Connect hose to Applicator and switch turbine on 6 Simply pull the Trigger back and aim t...

Страница 17: ...ole in the Gun Body The matching hole of the Gun Body is located at a 12 o clock position NOTE DO NOT SOAK THE WHOLE APPLICATOR IN ANY LIQUID THIS IS NEVER NECESSARY OR ADVISABLE Remove the Fluid Knob...

Страница 18: ...Brush and warm soapy water to clean behind the Fluid Nozzle 3 The Air Cap Fluid Nozzle Needle Air Diffuser and Air Divider may be soaked in warm soapy water Do not use solvents to soak or clean these...

Страница 19: ...filters on hand salonTAN Filter To remove simply pull the filter out from the bottom right side of the turbine Case if looking from the front To reuse wash the Filter in warm soapy water Dry before r...

Страница 20: ...om the grill 4 Clean and let dry or replace the foam filter and replace it in the grill 5 When placing the foam filter in the grill ensure each of the 6 tabs is helping to hold the foam in place 6 Mak...

Страница 21: ...Again pull the Trigger and release until the Needle moves back and forth freely Wipe away the water in between adjustments Repeat until no water is seen at the Fluid Nozzle Hole 4200 T PRO Bottom Fee...

Страница 22: ...h water Connect the Applicator to the hose and switch the Turbine on Pull the Trigger and release Check Needle Packing Nut 13 for water leaking out Use the supplied wrench to GENTLY tighten the Nut 1...

Страница 23: ...n Damaged Needle 8 or Fluid Nozzle 3 This will require replacement Check Fluid Nozzle and Air Holes in Air Cap 2 This will require cleaning Applicator is being held too far from surface max 6 inches 1...

Страница 24: ...o cool down If necessary reset the breaker switch then try turning on again Replace breaker if still not turning on 11 Little to no solution coming out Fluid Knob 7 is turned in too far turn out to al...

Страница 25: ...ations to the product are made or attempted Purchasers located in North America must obtain a Return Material Authorization number by calling Fuji at 1 800 650 0930 before returning the product to Fuj...

Страница 26: ...System Product name s HVLP Spray System Type Name Turbine Model s Q3 Model Q4 Model Q5 Model Mini Mite 3 Mini Mite 4 Mini Mite 5 studioTAN salonTAN Semi PRO 2 Hobby PRO 2 Conforms to the following nor...

Страница 27: ...NECT WITH US FUJISPRAYSUNLESS FUJISPRAYSUNLESS FUJISPRAY SUPPORT FUJISPRAY COM 1 800 650 0930 FUJISPRAY COM FUJISPRAYSUNLESS COM NEED HELP Fuji Industrial Spray Equipment Ltd 40 Magnetic Drive 48 Toro...

Отзывы: