
86
INZ-TN2ZPB-E
note1
:KHQ³'´LVVSHFL¿HGDWWKGLJLW3RZHUVXSSO\FRUGLVVXSSOLHGLQWKHVFRSHRIVXSSO\&RUGVSHFL¿FDWLRQVKRXOG
EHVSHFL¿HGDWWKHWKGLJLW
note2
:KHQLVVSHFL¿HGDWWKGLJLW2
2
pt analyzer signal has to be set as 0-1V DC linear corresponding to full scale.
External zirconia O
2
analyzer and external O
2
analyzer are not included in the scope of supply, and has to be
separately ordered.
note3) Select the range code for each range from the range code table shown above. Range of fuel cell O
2
analyzer is
YRORUPRUH
note4) Select the type of voltage rating, plug type and applicable standard of the power supply cord by 20th digit. Select
a power supply cord for using at the location of end-user.
note5) O
2
correction is calculated only for NO, SO
2
and CO.
note6
:KHQ FRPSRQHQWV PHDVXUHPHQW LV VSHFL¿HG + PXVW QRW EH VSHFL¿HG DW QG GLJLW :KHQ FRPSRQHQWV
PHDVXUHPHQWLVVSHFL¿HGDQG+LVVSHFL¿HGDWQGGLJLWSRLQWVLVPD[LPXPIRUDODUPRXWSXWIXQFWLRQ
note7
:KHQ%LVVSHFL¿HGDWWKGLJLWPHDVXULQJUDQJHVKRXOGEHVSHFL¿HGE\SSPUDQJHFRGH,QWKLVFDVH1262
2
and CO measuring range are corresponding range in mg/m
3
. Please refer to the table shown below for the
corresponding range code based on "mg/m
3
".
note8
:KHQ$LVVSHFL¿HGDWWKGLJLWWKHDQDO\]HUZLOOEHDGMXVWHGDQGGHOLYHUHGZLWKWKHEDODQFHJDV1
2
. When other
DGMXVWPHQWLVUHTXLUHGSOHDVHVSHFLI\=:KHQ=LVVSHFL¿HGSOHDVHDWWDFKDOLVWRIJDVFRPSRVLWLRQFRQWDLQHG
in the measuring gas.
Corresponding range in mg/
m
3
Range code
Corresponding
mg/m
3
A
B
C
D
S
E
F
G
U
T
H
Unit : ppm
0-50ppm
0-100ppm
0-200ppm
0-250ppm
0-300ppm
0-500ppm
0-1,000ppm
0-2,000ppm
0-2,500ppm
0-3,000ppm
0-5,000ppm
NO
0-65.0mg/m
3
0-130mg/m
3
0-260mg/m
3
0-325mg/m
3
0-400mg/m
3
0-650mg/m
3
0-1,300mg/m
3
0-2,600mg/m
3
0-3,300mg/m
3
0-4,000mg/m
3
0-6,600mg/m
3
SO
2
0-140mg/m
3
0-280mg/m
3
0-570mg/m
3
0-700mg/m
3
0-850mg/m
3
0-1,400mg/m
3
0-2,800mg/m
3
0-5,600mg/m
3
0-7,100mg/m
3
0-8,500mg/m
3
0-14.00g/m
3
CO
0-60.0mg/m
3
0-125mg/m
3
0-250mg/m
3
0-300mg/m
3
0-375mg/m
3
0-600mg/m
3
0-1,250mg/m
3
0-2,500mg/m
3
0-3,000mg/m
3
0-3,750mg/m
3
0-6,250mg/m
3
The conversion formula "ppm" unit
into "mg/m
3
" unit.
NO (mg/m
3
) = 1.34
×
NO (ppm)
SO
2
(mg/m
3
) = 2.86
×
SO
2
(ppm)
CO (mg/m
3
) = 1.25
×
CO (ppm)
RANGE CODE
O
2
measurement range
0~5/10 vol%
Measurement
range
Range
code
A
Fuel cell O
2
sensor
(built - in)
Zirconia O
2
sensor
(external)
Paramagnetic
O
2
sensor
(built - in)
0~5/25 vol%
B
0~10/25 vol%
C
0~5 vol%
L
0~10 vol%
M
0~25 vol%
V
0~50 vol%
P
0~100 vol%
R
0~50ppm
0~100ppm
0~200ppm
0~250ppm
0~300ppm
0~500ppm
0~1000ppm
0~2000ppm
0~2500ppm
0~3000ppm
Range
Code
A
B
C
D
S
E
F
G
U
T
0~5000ppm
0~1vol%
0~2vol%
0~3vol%
0~5vol%
0~10vol%
0~20vol%
0~25vol%
Others
Range
Code
H
J
K
Q
L
M
N
V
Z
4 5 6 7
1 2 3
Z P B
B
2
8
9 10 11 12 13
14 15 16 17 18 19 20
21 22 23 24 25
Description
note
note6
note7
note8
Digit
23
24
25
<Pressure compensation>
None
Pressure compensation
<Unit>
ppm, Vol%
mg/m
3
, g/m
3
<Adjustment>
For standard(combustion exhaust)
Others
Digit
Y
1
A
B
A
Z