11. Safety devices
Type of
protection
Protection form
Model
ROG07KMTA
ROG09KMTA
Circuit protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
85—122 °C
Fan motor stop
Reset
77—114 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Type of
protection
Protection form
Model
ROG12KMTA
ROG14KMTA
Circuit protection
Current fuse (Main PCB)
250 V, 20 A
250 V, 5 A
Fan motor
protection
Terminal protection
program
Activate
85—122 °C
Fan motor stop
Reset
77—114 °C
Fan motor restart
Compressor
protection
Terminal protection
program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
DESIGN & TECHNICAL MANUAL
- 58 -
OUTDOOR UNIT
ROG07-14KMTA
Содержание ROG07KMTA
Страница 5: ...Part 1 INDOOR UNIT WALL MOUNTED TYPE RSG07KMTA RSG09KMTA RSG12KMTA RSG14KMTA ...
Страница 10: ...3 Wiring diagrams 3 1 Models RSG07KMTA RSG09KMTA RSG12KMTA and RSG14KMTA 6 WALL MOUNTED RSG07 14KMTA ...
Страница 42: ... 38 WALL MOUNTED RSG07 14KMTA ...
Страница 43: ...Part 2 OUTDOOR UNIT SINGLE TYPE ROG07KMTA ROG09KMTA ROG12KMTA ROG14KMTA ...
Страница 52: ...5 Wiring diagrams 5 1 Models ROG07KMTA ROG09KMTA ROG12KMTA and ROG14KMTA 48 OUTDOOR UNIT ROG07 14KMTA ...