![Fuji Electric ROG07KMTA Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/fuji-electric/rog07kmta/rog07kmta_design-and-technical-manual_2341725023.webp)
7. Safety devices
Type of
protection
Protection form
Model
RSG07KMTA
RSG09KMTA
RSG12KMTA
Circuit
protection
Current fuse (PCB*)
250 V, 3.15 A
Fan motor
protection
Thermistor protection
Activate
More than 85 °C
Fan motor speed down
Reset
85 °C or less
Fan motor speed recover
Type of
protection
Protection form
Model
RSG14KMTA
Circuit
protection
Current fuse (PCB*)
250 V, 3.15 A
Fan motor
protection
Power IC thermal
shutdown protection
Activate
125±25 °C
Fan motor stop
Reset
110
+25
-20
°C
Fan motor restart
*PCB: Printed Circuit Board
- 19 -