![Fuji Electric NP4N-MDLW Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/fuji-electric/np4n-mdlw/np4n-mdlw_user-manual_2341953039.webp)
4-5
4-1 Setting SX_MDLW
<Procedure for parameter setting>
Set the communication parameter in the procedure given below.
<For RS-232C>
Set “COM Port” as the communication port type and specify the communication port, baud rate, data length, stop bits and
parity as the parameter. Place a 1-byte space between parameters.
Communication baud rate
→
38400, 19200, 9600, 4800 or 2400 (bps)
Data length
→
8 or 7 (bits)
Stop bits
→
1, 1.5 or 2
Parity
→
0, 1, 2 or 3 (0: No parity, 1: Odd parity, 2: Even parity, 3: Mark)
<Sample setting>
<For modem>
Set “Modem” as the communication port type and specify the modem name, tone/dial and phone number as the
parameter.
Modem name
→
As the modem name, enter the modem type enclosed in quotation marks.
Tone/dial
→
T: Tone, D: Dial
Phone number
→
Set the phone number. Example: 048-***-****
<Sample setting>
COM port: COM1
Baud rate:
38400 baud
Optional
Data length: 8 bits
Parity: Even
Stop bit: 1
Place a 1-byte space.
V
V
Modem name
Tone
Phone number