Fuji Electric NP4N-MDLW Скачать руководство пользователя страница 12

2-1

Section 2  Installation

2-1  Personal Computer Environment Necessary for

SX Communication Middleware

Because MICREX-SX Communication Middleware is incorporated in a user application for operation, its operation
environment is limited by the user application software specifications. The recommended execution environment for the
user application software incorporating the SX Communication Middleware is given below.

Items

Specifications

Hardware

IBM-AT compatible machine

CPU

Intel Pentium 233 MHz or equivalent

Hard disk driv

At least 1 drive

External storage device/
interface

Floppy disk drive

At least 1 drive, Media: 2HD, 1.25/1.44 Mbytes, 3.5 inches

CD-DOM drive

At least 1 drive (quadruple speed or more recommended),

Media: ISO9660 format

Memory capacity

128 Mbytes or more

Keyboard

106-type Japanese (A01) keyboard (CTRL + alphanumerics) or
101-type English keyboard

Mouse

USB, bus or PS2 mouse

Display (resolution)

1024 x 768 dots or more

Communication interface

Select one of the following interfaces:

COM port (RS-232C/modem)

Ethernet

FL-net

SX bus (SX bus slave board is necessary.) See Note.

Operating system necessary for SX_MDLW

WindowsNT 4.0 SP3 or up, Windows2000, WindowsXP

Note: Currently, SX bus slave boards (model: NP3L-SA1SASS) compliant with ISA bus are available.

The SX Middleware Software package is shipped as one CD-ROM. It contains the software itself, installer and product

Содержание NP4N-MDLW

Страница 1: ...FEH246a series USER S MANUAL MICREX SX Communication Middleware Models NP4N MDLW...

Страница 2: ...a r u g i f n o c m e t s y s s e i r e S X S X E R C I M e h t s e b i r c s e D s e l u d o m f o g n i l d n a h d n a s n o i t a c i f i c e p s e r a w d r a h e c n e r e f e R 2 V n i w 0 0 3...

Страница 3: ...age to the product or malfunction may occur The product CD is CD ROM Never try to play it on a general audio CD player or loud noise may cause hearing disability or audio equipment fault Insert loader...

Страница 4: ...s i o N l a u n a m e h T n o d e t n i r P o N l a u n a M s t n e t n o c n o i s i v e R 4 0 0 2 l u J 6 4 2 H E F n o i t i d e t s r i F 4 0 0 2 v o N a 6 4 2 H E F n e t t i r w e r s a w n o i...

Страница 5: ...ional Specifications 3 1 3 1 1 Execution environment 3 1 3 1 2 Development language for client 3 1 3 1 3 List of communication interfaces 3 1 3 2 Interfaces Supported by SX_MDLW 3 2 3 3 Accessing Proc...

Страница 6: ...1 1 Outline of NP4N MDLW 1 1 1 1 1 Data Communication System Configuration Image 1 1 1 1 2 Outline of system configuration 1 2 1 Basic system configuration 1 2 2 Expanded system configuration 1 3 1 2...

Страница 7: ...pervisory Control and Data Aquistion Hint OPC related information is available at the Web site of OPC Council Japan Address http www microsoft com japan partners industry opchome htm Section 1 Overvie...

Страница 8: ...ported SX_MDLW can access to the MICREX SX global variables without activating D300win Notes 1 The OS of the personal computer must be WindowsNT V4 0 SP3 or up Windows2000 or WindowsXP 2 Message Manag...

Страница 9: ...0 WindowsXP OPC client SX_MDLW OPC server D300win V2 2 0 1 and up Message manager MM WindowsNT V4 0 SP3 or up Windows2000 WindowsXP Dedicated interface Use RS 232C Ethernet etc for communications betw...

Страница 10: ...terface defined by OPC is necessary Knowledge about D300win Knowledge about D300win operations is necessary For development with OPC custom interface Category Items Knowledge about OLE COM Interface d...

Страница 11: ...Page 2 1 Personal Computer Environment Necessary for SX Communication Middleware 2 1 2 2 Installation Procedure 2 2 2 2 1 Initial screen 2 2 2 2 2 Installing SX Communication Middleware 2 3 2 3 Uninst...

Страница 12: ...disk drive At least 1 drive Media 2HD 1 25 1 44 Mbytes 3 5 inches CD DOM drive At least 1 drive quadruple speed or more recommended Media ISO9660 format Memory capacity 128 Mbytes or more Keyboard 106...

Страница 13: ...ive Then the screen shown below automatically appears Note If the installation screen shown above does not appear automatically perform the following procedure Click Windows Start Run specify the name...

Страница 14: ...iddleware Procedure 1 From the initial screen click Setup to start the installer Note If your personal computer runs on WindowsNT Windows Installer may not have been installed In this case install Win...

Страница 15: ...ect whether or not to accept the terms of the license 3 To agree with the terms of the license and continue installation select I accept the terms in the license agreement and click Next button The Cu...

Страница 16: ...ge the installation destination select Custom and click Next button 5 From Custom Setup screen click Change button and setup the installation destination After setup click Next button Clicking this bu...

Страница 17: ...2 6 2 2 Installation Procedure 6 The screen shown below appears From this screen click Install button to start installation The installation destination folder is shown here...

Страница 18: ...2 7 2 2 Installation Procedure 7 When installation has completed the screen shown below appears Click Finish button to exit the wizard screen...

Страница 19: ...ommunication Middleware and click Add Remove button Change Remove button for Windows2000 WindowsXP to invoke the screen shown below 2 Click Next button to invoke Program Maintenance screen From this s...

Страница 20: ...tion Procedure 3 Remove the program screen appears From this screen click Remove button to start uninstallation 4 When uninstallation has completed Completed screen appears Click Finish button to exit...

Страница 21: ...2 2 DA browser 3 3 3 OPC group collection 3 4 4 OPC group 3 5 5 DA item collection 3 6 6 DA item 3 6 3 3 Accessing Process Data 3 7 3 3 1 Item ID and access path 3 7 3 3 2 Basics of process data acce...

Страница 22: ...For connecting the machine running SX_MDLW and the MICREX SX system the communication interfaces given below are prepared n o i t a c i n u m m o C e c a f r e t n i e r a w d r a H e m a n t c u d o...

Страница 23: ...w d n a b e h t s n r u t e r t I r e v r e s e h t o t c i f i c e p s e u l a V r e v r e s e h t o t e l b a l i a v a s p u o r G C P O s t c e j b o p u o r g A D f o n o i t c e l l o C s e m a...

Страница 24: ...n o i t i s o p t n e r r u c e h t s n r u t e R t n u o C n o i t c e l l o c e h t n i s m e t i f o r e b m u n e h t s n r u t e R m e t I r e i f i c e p S m e t I h t i w d e x e d n i e m a n...

Страница 25: ...p u o r G C P O r o f D I e l a c o L t l u a f e d s t e S W R d d A s p u o r G s a i B e m i T p u o r G t l u a f e D d e t a e r c s p u o r G C P O r o f e t u n i m 0 s a i B e m i T t l u a f...

Страница 26: ...p U s m e t a r e t a d p u s e i f i c e p S W R s m e t I C P O s t c e j b o m e t I C P O f o n o i t c e l l o C d a e R c n y S p m a t s e m i t d n a g a l f y t i l a u q e u l a v a t a d e...

Страница 27: ...e i l c a s t e S s e p y T a t a D t e S p u o r g e h t n i m e t i n a r o f e p y t a t a d t s e u q e r a s t e S 6 DA item t c e j b O y t r e p o r P d o h t e M t n e v E w e i v r e v O m e...

Страница 28: ...acquired using the browse function In addition no access paths are used 3 3 2 Basics of process data access 1 Process data configuration Process data consists of three types of data shown below e p y...

Страница 29: ...B 1 l o o B T N I 6 1 r e g e t n I T N I D 2 3 r e g e t n i n o i s i c e r p e l b u o D T N I U 6 1 r e g e t n i d e n g i s n U T N I D U 2 3 r e g e t n i n o i s i c e r p e l b u o d d e n g...

Страница 30: ...CREX SX whish is Device according to UpdateRate Cache specification raises the response speed performance but increases the possibility of variation of the value from Device according to UpdateRate De...

Страница 31: ...ss has completed requested data is returned through another route Because a process from the OPC server is immediately transferred the OPC client is allowed to perform other processing until data is r...

Страница 32: ...led by SX_MDLW and that of projects accessed when acquiring an address in D300win are determined by OPC file setup of SX_MDLW Specifying large parameter values requires a lot of resources lowering the...

Страница 33: ...r e e n i g n e e h t n e h w D I C L a s a e u l a v a s n r u t e r r e v r e s C P O e h t n e h w d e s u r e i f i t n e d i e g a u g n a L g n i r t s r e t c a r a h c t c e j b o m e t I n o...

Страница 34: ...SX_MDLW Page 4 1 Setting SX_MDLW 4 1 4 1 1 Setting OPC server 4 1 1 Basic Setting 4 1 2 SX setting 4 2 3 Trace setting 4 8 4 2 Setting DCOM 4 10 4 3 D300win Related Settings 4 15 4 3 1 Exporting vari...

Страница 35: ...C P O e h T e t a d p u s i h T r e v r e s C P O e h t y b d e t r o p p u s e b n a c t a h t e l c y c m u m i n i m e h t t e s e r e H e l c y c e r e h t e s e u l a v e h t d e e c x e t o n n...

Страница 36: ...ocedure 1 Click MICREX SX Setting tab from OPC Server settings dialog to display the screen shown below 2 Set whether or not to start D300win in the D300win group D300win group Specify whether or not...

Страница 37: ...ject containing the global variable worksheet to be accessed by SX_MDLW and click Open button to display the project selected in the project path from OPC Server settings Click the global variable wor...

Страница 38: ...variable and click Communication Setting button to display Communication Setting dialog From this dialog set the parameter for communications between SX_MDLW and MICREX SX For Communication Data Size...

Страница 39: ...2400 bps Data length 8 or 7 bits Stop bits 1 1 5 or 2 Parity 0 1 2 or 3 0 No parity 1 Odd parity 2 Even parity 3 Mark Sample setting For modem Set Modem as the communication port type and specify the...

Страница 40: ...number 1 to 64 Sample setting SX bus board When using SX bus slave boards a maximum of four SX bus slave boards are available Select the communication port type from SX bus board 0 through SX bus boa...

Страница 41: ...means that the set project does not exist on the project path for a certain reason or it has been deleted When Not Exist is displayed delete the data or make the setting again If SX_MDLW is started le...

Страница 42: ...lder Procedure 1 From OPC Server settings dialog click Trace File Setting tab to display the screen shown below From this screen select the information to be traced Set items n o i t p i r c s e D o N...

Страница 43: ...trace file are as shown below 1 Indicates time 2 Indicates the method executed by SX_MDLW 0 or 9 enclosed in circle indicates that there has been a call from the client or the server has completed me...

Страница 44: ...m Start menu specify dcomcnfg exe and click OK button Then Distributed COM Configuration Properties dialog appears 2 OPC MICREX SX Properties dialog appears Click Security tab from OPC MICREX SX Prope...

Страница 45: ...4 11 4 2 Setting DCOM 3 Registry Value Permissions dialog appears From this dialog click Add button and add Everyone All Users Select Everyone and click Add button...

Страница 46: ...e user who can start the application Check Use custom launch permissions and click Edit button 5 Registry Value Permissions dialog appears From this dialog click Add button and add Everyone All Users...

Страница 47: ...13 4 2 Setting DCOM 6 Specify the account to be used for application execution Click Identity tab check The interactive user and click OK button Distributed COM Configuration Properties dialog reappea...

Страница 48: ...K button to complete DCOM settings Though Everyone is set for access permissions in this manual a specific user may also be set for accessing Customize it depending on the operational environment Set...

Страница 49: ...cannot access local variables Note When a project has been modified online SX_MDLW may not operate normally If a project has been modified online be sure to restart SX_MDLW If an exported project is t...

Страница 50: ...labels dialog 2 From Export labels dialog set the configuration resource and export destination folder for the global variable to be exported and click Export button When export has completed the dia...

Страница 51: ...Section 5 Connecting from an OPC Client Page 5 1 Preparing for SX_MDLW OPC Server Connection 5 1 5 2 Connecting to SX_MDLW 5 2 5 3 Registering Groups 5 2 5 4 Registering Items 5 2...

Страница 52: ...ed to SX_MDLW OPC server Connect SX_MDLW and OPC client in the procedure described below Create project Download project Starting D300win for communication Export variable name Set SX_MDLW Start OPC c...

Страница 53: ...ternally and in such a case manual registration of the group is not necessary For details about connections refer to sections related to OPC connections in SCADA software manuals 5 4 Registering Items...

Страница 54: ...ooting Page 1 SX_MDLW cannot start 6 1 2 SX_MDLW goes down when an OPC server tries to connect to the server 6 1 3 The server functions not in the way specified in processing instructions 6 1 4 Browsi...

Страница 55: ...r Make reinstallation 2 SX_MDLW goes down when an OPC server tries to connect to the server The proxy stub registration information may contain an error Make reinstallation 3 The server functions not...

Страница 56: ...Gate City Ohsaki East Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan E mail micrex sx fujielectric co jp URL http www fujielectric com Materials covered in this document are subject to rev...