3-1 

Chapter 3  OPERATION USING THE REMOTE KEYPAD "TP-E1" 

3.1 

 

Familiarizing Yourself with the Remote Keypad 

The Remote Keypad is composed of a 4-digit, 
7-segment LED monitor, an LED display 
section consisting of 5 LEDs, and 6 keys as 
shown in Figure 3.1. 

 

 

Figure 3.1  Overview of Remote Keypad 

Table 3.1  Names and Functions of Various Parts of Remote Keypad 

Group

Name

Function

Remarks

Data display 

7-segment  
LED monitor 

Displays the running status, data settings, 
alarm status, etc., depending on the 
operation mode. 

 key 

Switches the operation mode*. 

 key 

Depending on the operation mode, 
switches the information displayed, fixes 
the function code data, or switches the 
alarm information displayed. 

 key 

 key 

These keys are used to selects the setting 
items displayed on the LED monitor and 
change the function code data. 

 key 

Starts the motor. 

Keys 

 key

Stops 

the 

motor.

RUN LED 

Lights when a Run command is given to 
the Inverter. 

KEYPAD 
CONTROL LED 

Lights when the inverter is operating 

under the Run command activated by 

the 

 key. 

*Operation mode: 

• Running 

mode

• Programming

mode 

• Alarm 

mode

kW, A, Hz, r/min, m/min: 
These 3 LEDs together as a group 
indicate the unit of the quantity being 
monitored. 

See Table 3.2. 

LED display 

3 unit LEDs 

PRG

.

 MODE

:

 

Two LEDs (right and left) light in 
Programming mode. 

 

  For the operation mode of the FRENIC-Mini and its operating procedures, refer to the 

FRENIC-Mini Instruction Manual (INR-SI47-0791-E), Chapter 3 "OPERATION USING THE 
KEYPAD." 

LED display

DOWN key

STOP key 

UP key 

FUNCTION 
/DATA key 

RUN key 

7-segment LED monitor 

PROGRAM 
/RESET key 

Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]

Содержание Frenic Mini TP-E1

Страница 1: ...ling blocks correct operation or causes a short life or failure Deliver this manual to the end user of the product Keep this manual in a safe place until the Remote Keypad is discarded For the usage o...

Страница 2: ...ten permission from Fuji Electric FA Components Systems Co Ltd All products and company names mentioned in this manual are trademarks or registered trademarks of their respective holders The informati...

Страница 3: ...unction with this manual as necessary FRENIC Mini User s Manual MEH446 RS485 Communications User s Manual MEH448 Catalog MEH441 MEH451 Application Guide MEH449 FRENIC Mini Instruction Manual INR SI47...

Страница 4: ...le the key Prepare an emergency stop switch separately If you disable the STOP key priority function and enable command FWD or REV you cannot stop the inverter output by the key on the built in keypad...

Страница 5: ...rol circuit wires come into direct contact with the live main circuit terminal therefore the sheath may break Accordingly there is a possibility that high voltage on the main circuit may be applied to...

Страница 6: ...G THE REMOTE KEYPAD TP E1 This chapter describes the functions of the Remote Keypad including data copying as well as how to operate the Remote Keypad Chapter 4 SPECIFICATIONS This chapter lists the g...

Страница 7: ...essories and Parts Required for Connection 2 1 2 2 Installing the Remote Keypad 2 2 Chapter 3 OPERATION USING THE REMOTE KEYPAD TP E1 3 1 3 1 Familiarizing Yourself with the Remote Keypad 3 1 3 2 Oper...

Страница 8: ...aces The Remote Keypad TP E1 interfaces with the following Fuji inverters Series Type of inverter Remarks FRENIC Mini FRN C1S FRN C1E Each has its meaning as shown below represented by an alphanumeric...

Страница 9: ...Remarks Remote Operation Extension Cable Note 1 CB 5S CB 3S or CB 1S You have a choice of three lengths 5 m 3 m and 1 m RS485 Communications Card OPC C1 RS Install this into the inverter Screws for mo...

Страница 10: ...closure e Install the RS485 Communications Card on the inverter f Insert the connector on one end of the Remote Operation Extension Cable or LAN cable into the RJ 45 modular jack on the Remote Keypad...

Страница 11: ...nsions of Square Hole and Screw Holes d Mount the Remote Keypad TP E1 onto the enclosure with 2 screws as shown in Figures 2 3 and 2 4 Recommended tightening torque 0 7 N m Figure 2 4 Mounting Remote...

Страница 12: ...ect contact with the live main circuit terminal therefore the sheath may break Accordingly there is a possibility that high voltage on the main circuit may be applied to the control circuit wires It i...

Страница 13: ...close the TB cover Take care not to pinch control signal wires cables between the TB cover and the body of the FRENIC Mini f Insert the connector on one end of the Remote Operation Extension Cable or...

Страница 14: ...or EMC compliance using clamps provided Figure 2 9 Shielded Wire Connection to Comply with EMC Directives Figure 2 10 Grounding Shields to Comply with EMC Directives For EMC directives refer to the FR...

Страница 15: ...sed to selects the setting items displayed on the LED monitor and change the function code data key Starts the motor Keys key Stops the motor RUN LED Lights when a Run command is given to the Inverter...

Страница 16: ...peed output current A output voltage V timer s input power kW PID process command and PID feedback amount In speed monitoring one of the following can be selected output frequency before slip compensa...

Страница 17: ...copied is summarized in the FRENIC Mini Instruction Manual INR SI47 0791 E Chapter 5 the Data copy column of Section 5 1 Function Code Tables using the following designations Y Can be copied unconditi...

Страница 18: ...ng data copying operation while Table 3 4 shows details of the data copying functions The memory of the Remote Keypad can save function code data for one inverter Figure 3 2 Status Transition during D...

Страница 19: ...in the memory of the Remote Keypad into the inverter Pressing the key during the write operation while CoPy is blinking aborts the write copy operation causing E to blink on the LED monitor see Note...

Страница 20: ...ter during data copying the appears on the monitor and the following problems will arise with the Remote Keypad and or inverter depending upon the actual operation being in progress Take the necessary...

Страница 21: ...low Note Atmospheric pressure 86 to 106 kPa Vibration 3 mm max 2 9 Hz 9 8 m s 2 9 20 Hz 2 m s 2 20 55 Hz 1 m s 2 55 200 Hz Ambient temperature during storage 25 to 70 C Ambient humidity during storage...

Страница 22: ...ce for Remote Keypad 5 V 2 7 GND Signal ground GND 3 6 NC Unassigned reserved 4 DX RS485 communication data 5 DX RS485 communication data Note SW1 for the terminating resistor on the RS485 Communicati...

Страница 23: ...e FRENIC Mini series of inverters Please feel free to send your comments regarding any errors or omissions you may have found or any suggestions you may have for generally improving the manual In no e...

Страница 24: ...Fuji Electric FA Components Systems Co Ltd 2003 6 c03 c03 1CM Buy www ValinOnline com Phone 844 385 3099 Email CustomerService valin com...

Отзывы: