1.3 Functions
The FALDIC-
α
series has 3 types of control function for particular applications.
(1) RYS-V type : Pulse train/speed control (velocity)
Maximum input frequency 500 [kHz]
Rotates according to pulse train from host control equipment, or
speed command from encoder or variable resistor.
The host interface has :
・
DI/DO speed (minimum DI/DO),
・
SX bus type,
・
Open network, etc.
(2) RYS-L type
:
:
:
:
Linear positioning system (linear motion)
Maximum command value
±
79,999,999
The amplifier can compose a linear positioning system,
combined with ball-screw, timing belt, rack and pinion or other
mechanisms.
As positioning data, 99 sets (points) of position, current
(present) position output, immediate positioning, M-code
output etc. can be registered.
The host interface has
:
・
DI/DO position (expanded DI/DO),
・
SX bus type,
・
T-link type,
・
Open network, etc.
(3) RYS-R type
:
:
:
:
Rotation indexing system (rotation)
Maximum indexing number 30000
The amplifier can compose a rotation indexing system,
combined with ATC, tool magazine, loader/unloader, etc. or
other mechanisms.
The rotation indexing system is usable for shorted route control,
2nd origin, one-point halt, single-direction infinite rotation, etc.
The host interface has
:
・
DI/DO position (expanded DI/DO),
・
SX bus type,
・
T-link type,
・
General-purpose communication (RS485 interface),
・
Open network, etc.