Type

Outline dimensions

Control box

Type

AR9Y920

Application:
•  Plastic control box for mounting the emergency stop pushbut-

ton switch separately.

• Mounting pitch

58

[Unit: mm]

…

79

ø22.3 (Equipped with a protrusion)

Be sure to use and store the product within the rated ambient temperature and humidity ranges.

Although the product resists ordinary cutting oils and coolant oils, do not use the unit in places where special oils may be

 

sprayed onto the product. If you 

experience this issue

please contact 

Fuji Electric.

If dusts or filings accumulate in the gap between the button and the frame, the switch may fail to operate normally.

This switch are for indoor use. Don’t use the switch for outdoor use and make sure that the product is not exposed to direct

 

sunlight.

Do not use the product in the places that are subject to the adverse effects of ozone or corrosive gases. 

Features

• Control box for mounting the emergency stop pushbutton switch AR22VQR/VQL, VPR.
• It is easy to mount or add this box to the desired places away from the operating panel.
• Degree of protection : IP65 (when using applicable connector)
• Double-insulation structure without the need for an earth wire. (compliant with IEC536 class II)
• The knockout holes open at the top, bottom, and back.
• The emergency stop Legend plate (AR9P722) can be mounted.

Storage and Usage Locations

Control box dedicated for emergency stop pushbutton switch

Accessories

Description

Type

Dimensions

Wrench

Type

Used with

AR9A701

AR22VQR, VQL, VPR

AHX536

AR30VPR, VPL

Application:
This allows you to tighten the tightening ring when mounting the 
command switch on a panel.

AR9A701: ø28 mm × 60 mm
AHX536  : ø32 mm × 76 mm

Legend plate

Type

Used with

AR9P722-(1)(2)

AR22VQR, VQL

AR9P723-(1)(2)

AR22VPR

AR9P724-(1)(2)

AR30VPR, VPL

Note 1:  The values of code (1) and (2) above represent the Legend 

below to be printed on the Legend plate

Type

Code (1), (2)

Letter height

Blank

00

EMERGENCY STOP

5A

5 mm

Note 2:  These Legend plate are pasted on the product.
Note 3:  The Legend plate is yellow and the Legend 

text

 is

 black

[Unit: mm]

ø60 *

1

ø23 *

2

Thickness: 0.35

*1

: AR9P723: ø80

*2

: AR9P724: ø31

AR22VQ

†

, VPR

ø30 mounting adapter

Type

AR9Y958

Application:
•  This adapter allows you to 

mount the switch on a panel of 
ø30.5mm cutout in combination 
with the operator of AR22VQ

†

 

and VPR (made of plastics, with 
ring packing and tightening nut).

•  The applicable panel thickness is 

1 to 4.5 mm.

[Unit: mm]

ø30 mounting adapter 

ø30 packing  ø30 tightening nut

ø45

2.5

5.5

0.5

6

ø30

ø42.4

ø22.2

ø41

ø30.3

ø40

ø36.5

r max = 0.8mm

4.8

+0.2

mm

0

33

+0.5

mm

 0

ø30.5

+0.5

mm

  0

Applicable 

connector

• Knockout holes at the top and bottom: M20, Pg13.5, or G1/2
• Knockout holes at the back: M14 or G1/4

Applicable panel cutout size

62

Screw diameter: M4

41

* Tightening torque for mounting screws : 

1.6 to 2.0 N

s

m

Содержание AR22VQR/VQL

Страница 1: ...62E9 E 0185 22 30 Command Switches Equipped with Synchro Safe Contact Emergency Stop Pushbutton Switches AR22VQR VQL VPR AR30VPR VPL CONTROL...

Страница 2: ...tact arrangement 1 Type Button color Push lock turn reset or pull reset Mushroom head 40 AR22VQR 1NC AR22VQR 01R Red R 1NO 1NC AR22VQR 11R 2NC AR22VQR 02R 1NO 2NC AR22VQR 12R 1NO 3NC AR22VQR 13R 4NC A...

Страница 3: ...by default for the degree of protection of operator IP65 and the degree of protection of terminal section IP2X compliant with EN60204 1 The arrows on the button have been standardized to the same colo...

Страница 4: ...elease cover and turn the cover to the left Removal Support for Padlock Enhanced operability Enhanced routing Since the layout of each contact is fixed regardless of the number of contacts any miswiri...

Страница 5: ...air thermal current rated thermal current Ith Rated operational voltage Ue Rated operational current Ie AC DC AC 15 Inductive load AC 12 Resistive load DC 13 Inductive load DC 12 Resistive load 5 A 2...

Страница 6: ...f it seems that tightening is not suf cient do not forget to tighten the screw increasingly Note 4 Do not use pliers or other improper tools to tighten the nut and do not tighten it excessively or the...

Страница 7: ...stop Legend plate AR9P722 can be mounted Storage and Usage Locations Control box dedicated for emergency stop pushbutton switch Accessories Description Type Dimensions Wrench Type Used with AR9A701 AR...

Страница 8: ...rs Before mounting this product wiring cables operating this product or maintaining and inspecting this product make sure you read this Instruction Manual and use this product properly Recommended Pad...

Отзывы: