7
GAS
REQUIREMENTS
:
LP
GAS
Locate the brass nozzle inside each burner unit with pre-
attached NG gas ori ce. The ori ce is the small screw on the
end of the nozzle with a hole in the center. Unscrew the NG
gas ori ce by turning counter-clockwise and replace with LP
ori ce.
Use the 1.30mm ori ces for each gas and infrared unit
and the 1.05mm ori ces for the two cook unit burners.
The
LP ori ce has a smaller hole in the center to keep the ow of
LP gas consistent. You will need to replace the ori ces in each
unit (Fig. 02)
To connect the LP regulator and hose assembly to the tank/
valve assembly, rst make sure the main valve on the tank
is completely closed. Although the ow of gas is stopped
when the Type 1 system is disconnected as part of its safety
feature, you should always turn off the LP tank main valve
(FIG. 02) after each use and during transport of the tank or
unit. Insert the regulator inlet into the tank valve and turn the
black coupler clockwise until the coupler tightens up. Do not
overtighten the coupler. Turn the main tank valve on and turn
the burner control valves on the unit to “HIGH” position for
about 20 seconds to allow the air in the system to purge. Turn
valves off and wait 5 minutes before attempting to light the
burners.
To disconnect the coupler, rst make sure the main tank valve
is turned off. Grasp the coupler and turn counter-clockwise.
The inlet will then disengage. Remove the inlet from the tank
valve opening if it has not already done so when disengaging.
Your local LP lling station should be equipped with the proper
equipment to ll your tank.
LP TANK REQUIREMENTS:
A dented or rusty LP tank may be hazardous and should be
checked by your LP supplier. Never use a cylinder with a
damaged valve. Always check for leaks after every LP tank
change. The LP gas cylinder must be constructed and marked
in accordance with the speci cations for LP gas cylinders of
the U.S. Department of Transportation (DOT or CAN/CSA-
B339) and designed for use with a Type 1 system only. Do not
change the regulator and hose assembly from that supplied
with the unit or attempt to use a Type 1 equipped regulator
and hose assembly with a standard 510 POL tank/valve
assembly. The cylinder must be provided with a shutoff valve
terminating in an LP gas supply cylinder valve outlet speci ed,
as applicable, for connection Type 1. If the appliance is stored
indoors, the cylinder must be disconnected and removed from
the appliance. Cylinders must be stored outdoors in a well-
ventilated area out of the reach of children.
NOTE:
When an LP unit is directly attached into an LP house
system, the step down regulator MUST be used to reduce the
supply pressure to a max. 14" W.C. and min. 11" W.C. to the grill
regulator.
Fig. 01 LP Gas
TYPE 1
LP TANK
FA20ALP
LP HOSE
WITH
REGULATOR
Installation must conform with local
codes or with the National Fuel Gas
Code ANSI Z223.1 or the CAN/CGA-
B149.2 Propane Installation Code
Fig. 02 Ori ce Replacement
NOTE:
Do not use LP ori ces with natural
gas or NG ori ces with an LP gas tank.
Содержание FM20ACU
Страница 30: ...30 MAINTENANCE COOKING TIPS COOKING TIMES...
Страница 35: ...35...