In-line Logging 

In order to view and collect data on a variable, it must be logged.  In-line Logging provides the user an 
option to set up simplified Logging and add variables to Current Conditions from the Sensor Setup 
screen .  However, In-line Logging does not have the full functionality of regular logging using the 
functions in the Data screens.  Logging of the variables will be in accordance with the sensor read 
times and no logging offset can be input.  Additionally, although In-line Logging can be viewed 
through the Data functions, it can only be amended through the WindSonic Sensor Setup screen. 
 
 

NOTE:

  In-Line Logging does not have the full functionality as setting up Logging 

through the Data screen. 

 

1)

 

Select the Edit button 

, then Input the desired the Logging Interval (press on the hour, 

minute, or second box to highlight it in blue and use the arrows to select the value). 

 

 

Figure 3-4:  In-line Logging Setup  

 
2)

 

Check Enable Logging and if you want these values to be displayed in Current Conditions, 

 

check the Current Condition box.  The logging interval will now be displayed in green in the 

 

Logging Intervals screen (Data>Setup). 

 

3)

 

Select OK.  Return to the Home Page 

 

3.3

 

Regular Logging 

If the In-line Logging option was not used, you must set up logging in order to view and collect data 
on a variable.  Regular logging provides the user the ability to create more complex logging than that 
offered by the In-line Logging option.   
 
1)

 

From the Home page, select the Data icon and then the Setup Cog. 

Содержание THS-3

Страница 1: ...1 800 548 4264 www ftsenvironmental com 700 THS3 Rev 6 05 May 2015 THS 3 Temperature and Humidity Sensor Installation and Quick Setup Guide...

Страница 2: ...ental com 700 THS3 Rev 6 05 May 2015 Contact information FTS 1065 Henry Eng Place Victoria B C V9B 6B2 CANADA www ftsenvironmental com Toll free 1 800 548 4264 Local 250 478 5561 Technical support htt...

Страница 3: ...1 General Description 3 1 2 Specifications 4 Chapter 2 Installation and Maintenance 5 2 1 General 5 2 2 Tower Mounting 5 2 3 Maintenance 7 Chapter 3 Sensor Quick Setup Guide 9 3 1 Configuring the THS...

Страница 4: ...humidity 0 to 1 Vdc equals 0 to 100 RH on the sensor connector The T H sensor assembly see Figure 1 1 houses the sensors and associated electronics Both sensors are protected from air borne contamina...

Страница 5: ...und Power Humidity Output K Temperature Ground thermistor others No Connect Table 1 THS Sensor Signal Connections 1 2 Specifications The specifications for the THS 3 Temperature and Humidity Sensor ar...

Страница 6: ...eight Correct installation height is dependent on regulations for the jurisdiction in which the equipment is to be deployed Ensure you review local regulations prior to installation In the United Stat...

Страница 7: ...2015 Figure 2 1 Attaching the assembly to the support arm 2 Loosely attach the support arm to the mast or tower with the clamp bolts at the desired sensor height Ensure the support arm s V is fitted t...

Страница 8: ...n the open in a shade free area to ensure accurate temperature readings b The sensor should be well away from external sources of heat i e any equipment at the site that might generate heat c The sens...

Страница 9: ...en key to remove the three bolts securing the base of the sensor to the base plate of the housing assembly Figure 2 4 Sensor base showing bolts c Gently remove the sensor and inspect the filter for cl...

Страница 10: ...ce NOTE After installation the sensor should be given a minimum of thirty minutes to acclimatize to a site before data is taken 3 1 Configuring the THS 3 1 Connect the THS 3 to the data logger on the...

Страница 11: ...t select the F radial button Humidity This is the relative humidity Clip at 0 100 If checked causes the datalogger to limit humidity values read from the sensor to the range of 0 to 100 That is any ai...

Страница 12: ...Line Logging does not have the full functionality as setting up Logging through the Data screen 1 Select the Edit button then Input the desired the Logging Interval press on the hour minute or second...

Страница 13: ...bed here are displayed in blue Logging intervals created using the In line Logging feature are displayed in green Figure 3 6 Logging Intervals 3 Press the Add icon then the Edit icon Set the desired l...

Страница 14: ...he Home page 3 4 Confirm Sensor Operation Now that the THS 3 is setup confirm its operation and ensure data is being logged 1 From the Home page select the Data icon to display the Data Status screen...

Страница 15: ...turn to the Home page 3 5 Changing the Setup If you want to change the setup from the Home page select the blue Sensors icon then select the THS icon Select the Set up Cog which will bring you to the...

Страница 16: ...vision Date Description 1 27 Jul 2006 Original release 2 2 Oct 2006 Updated specifications 3 25 Jan 2007 Added special order specification 4 11 Oct 2007 Updated for new filter updated specifications 5...

Отзывы: