Protection
3
A. Over-Voltage Protection
B. Over-Current Protection
There will be protection from an output over-current event. The power supply
may shut down from such an event and require power-on restart.
C. Short-Current Protection
Output short circuit is defined to be a short circuit load of less than 0.1 ohm.
In the event of a short circuit condition on the +3.3V, +5V or +12V(-12V) output,
the power supply will shut down and latch off without damage to the power supply.
The power supply should return to normal operation after the short circuit has been
removed and the power switch has been turned off for no more than 2 seconds.
Voltage Source
Protection Point
+3.3V
+5V
+12V
13.0V-16.5V
3.76V-4.8V
5.6V-7.0V