Electrical Connections

Be sure to check the data plate, located on the liner of the cabinet, for required voltage prior to connecting the

unit to power.  The specifications on the data plate supersede any future discussion.

The standard unit is equipped with an eight (8) foot Power Cord that requires a 115 Volt, 60 Cycle, 1 phase

properly grounded 

electrical receptacle.  The Power Cord comes with a 3 prong plug for grounding pur-

poses.  Any attempt to cut off the grounding spike or to connect to an ungrounded adapter plug will void the

warranty, terminate the manufacturers responsibility and could result in serious injury.

The electrical circuit must be protected with a 15 or 20 ampere fuse or breaker.  The unit must be isolated on

a circuit and not plugged into an extension cord.

OPERATION

Initial Start Up

After satisfying the installation requirements, the freezer is ready to start.  The unit will start when the Power

Cord is connected to the required power source.  If the Compressor does not start when the unit is initially

plugged in, check to make sure that the Temperature Control is not in the ‘off’ position.  Allow the unit to run for

two hours before loading it with product.  When loading the unit with product do not load above the ‘product

load line’ indicated on the liner.

Temperature Control

The Temperature Control is located at the front of the condensing unit area.  Turn the Temperature Control

knob clockwise to obtain colder cabinet temperatures and vice versa.  Allow the unit a minimum of two hours

to respond to a control setting adjustment.

Defrost

Both Silver King Models SKDI and SKFS are manual defrost units.  The unit should be defrosted whenever

the walls accumulate a frost layer that is 1/4 inch thick. To defrost the unit, first unload the product from the

unit, then either turn the Temperature Control knob to the ‘off’ position (fully counterclockwise) or disconnect

the Power Cord from the electrical receptacle, and remove or open the Lid.  After the frost has melted or come

loose from the walls, wipe out the cabinet interior.  Do not attempt to scrape or chisel off the frost as you could

do irreparable damage to the unit.

MAINTENANCE

Preventative maintenance is minimal although these few steps are very important to continued trouble free

operation and maximizing the life of your appliance.

Cabinet Surfaces

The cabinet interior and exterior surfaces should be cleaned periodically with a solution of warm water and

mild soap and wiped dry with a soft cloth.  Should a surface become discolored, do not attempt to clean with

an abrasive cleanser or scouring pad.  Use a soft cleanser and rub with the grain of the metal to avoid

scratching the surface.

Condenser

Periodically, accumulated dust must be removed from the Condenser.  First, disconnect the unit from the

power supply.  To clear the dust, vacuum or brush the Condenser fins located at the bottom front of the

cabinet.  This will need to be done regularly to maintain the Compressor warranty!

P/N 90014

Содержание Silver King SKDI

Страница 1: ......

Страница 2: ...unit and to maintain the compressor warranty Model SKDI The Model SKDI is designed to drop into a counter or bar for convenient serving A square cutout of 16 5 inches by 16 5 inches is required to drop the cabinet into the countertop The counter must be able to support a weight of at least 125 pounds or the unit should be supported from the bottom Once installed into the countertop a bead of silic...

Страница 3: ... the front of the condensing unit area Turn the Temperature Control knob clockwise to obtain colder cabinet temperatures and vice versa Allow the unit a minimum of two hours to respond to a control setting adjustment Defrost Both Silver King Models SKDI and SKFS are manual defrost units The unit should be defrosted whenever the walls accumulate a frost layer that is 1 4 inch thick To defrost the u...

Страница 4: ...SKDI Le Modèle SKDI est conçu pour s introduire facilement dans un comptoir ou un bar pour la commodité du service Un évidement carré de 16 5 pouces x 16 5 pouces 41 9 cm x 41 9 cm est requis pour introduire l armoire dans le dessus de comptoir Le comptoir doit pouvoir supporter un poids d au moins 125 livres 56 7 kg ou l appareil doit être soutenu à partir du bas Une fois l installation faite dan...

Страница 5: ...atures plus froides tournez le bouton de réglage de température dans le sens horaire et vice versa Laissez à l unité au moins deux heures pour répondre à un réglage de fixation de régulation Dégivrage Les deux modèles SKDI et SKFS de Silver King sont des appareils à dégivrage manuel L appareil doit être dégivré chaque fois que les parois accumulent un couche de givre ayant une épaisseur de 1 4 de ...

Страница 6: ...n und die Garantie für den Kompressor erhalten bleibt Model SKDI Das Modell SKDI ist so konzipiert dass es in einen Tresen oder in eine Bar eingebaut werden kann was die Bedienung leichter macht Für den Einbau des Gehäuses muß ein rechteckiger Ausschnitt mit 41 25 cm Seitenlänge in dem Tresen herausgegeschnitten werden Der Tresen muß das Gewicht des Geräts 50 kg tragen können sonst muß das Gerät v...

Страница 7: ...um auf die neue Einstellung des Temperaturreglers zu reagieren Abtauen Beide Modelle von Silver King SKDI und SKFS können manuell abgetaut werden Die Geräte sollten immer dann abgetaut werden wenn sich eine Eisschicht von etwa 1 cm Dicke an den Wänden gebildet hat Vor dem Abtauen müssen zunächst alle Produkte von dem Gerät entfernt werden dann entweder den Temperaturschalter auf die Position Off d...

Страница 8: ...el gabinete Para instalación se necesita un mínimo de seis 6 pulgadas para circulación de aire adecuado al condensador y para mantener la vigencia de la garantía Modelo SKDI El modelo SKDI está designada para poner en un mostrador o barra para la conveniencia Es necesario a cortar un caudrado de 16 5 x 16 5 pulgadas para poner el gabinete en el mostrador El mostrador tiene que soportar un mínimo d...

Страница 9: ... más bajas gire la perilla de Control de temperatura en el sentido de las agujas del reloj y viceversa Espere un mínimo de dos horas para que la unidad responda a un ajuste de control Descongelamiento Los dos congeladores Silver King son unidades de descongelamientos manuales La unidad debe ser descongelada cada vez que las paredes acumulen una capa de escarcha de un grosor de 1 4 pulgada Para des...

Страница 10: ...9 MODEL SK FS FRONT VIEW MODEL SK FS SIDE VIEW ...

Страница 11: ... RELAY OVERLOAD 10344 34 5 GROMMET COMPRESSOR MOUNT 20481 6 CLIP HAIRPIN 98106 7 CONDENSER COIL 43647 8 FAN MOTOR 115 60 22048 FAN MOTOR 230 50 43193 9 FAN BLADE 6 5 23505 10 CONTROL BRACKETAND PLATE 21093 11 TEMPERATURE CONTROL 115V 21332 TEMPERATURE CONTROL 230V 43145 12 KNOB TEMPERATURE CONTROL 20651 13 POWER CORD 115V 43263 POWER CORD 230V 23514 14 FRONT COVER 41890 15 REAR COVER 41889 16 ASSY...

Страница 12: ...11 FORM NO 26231 12 00 WIRING DIAGRAM Models SKFS AND SKDI 115V 60Hz 1 PH OR 230V 50 Hz 1 PH For all service warranty or spare parts requirements please call 03 9368 2300 ...