Safety Precautions

 

•  All operating instructions must be read and understood before the product is operated.

•  These safety and operating instructions must be kept in a safe place for future reference.

•  All warnings on the product and in the instructions must be observed closely.

•  All operating instructions must be followed.

•  Do not use attachments or accessories not recommended by the manufacturer. Use of inadequate 

attachments may result in serious accidents.

•  Do not place heavy objects on the power cord. Route power cord to prevent people from stepping 

on or resting objects on the cord. Check to ensure that both outlet and product connection points 

are properly seated and secured.

•  This product must be operated on a power source as specified on the specification label or product 

screening.  Always operate the product within the voltage range specified.

•  Do not overload AC outlets or extension cords. Overloading can cause fire or serious electric shock.

•  Never insert an object into the product through vents or openings as this can cause serious electric 

shock or damage.

•  Do not expose product to water or other liquids as this can lead to electrical shock or permanent 

damage.

•  Do not attempt to service the product yourself. Removing covers can expose you to high voltage 

and other unsafe conditions. Please seek the assistance of a qualified service professional for all 

service needs.

•  If any of the following occur, unplug the power cord from the AC outlet and consult a qualified service 

professional to perform repairs:

•  Power cord or plug becomes damaged.

•  When any liquid is spilled on or in the product.

•  When the product has been exposed to rain or water.

•  When the product does not operate properly as described in the instruction manual.

•  When the product has been dropped or damaged.

•  Keep this product away from heat generating sources such as radiators, heaters, stoves, or other 

heat generating products.

•  If  the  product  requires  replacement  parts,  make  sure  that  the  service  person  uses  replacement 

parts specified by the manufacturer, or those equivalent parts having the same characteristics and 

performance specifications as the original parts. Use of unauthorized parts can result in fire, electric 

shock, and/or other damage. 

•  Upon completion of any service or repair work, request that the service technician perform safety 

checks to ensure that the product is in proper working order.

•  When  mounting  the  product  to  a  wall,  ceiling,  or  within  a  rack/enclosure,  be  sure  to  install  the 

product according to the instructions of both the mount and monitor manufacturer.

•  Unplug the power cord from the AC outlet before cleaning the product. 

Содержание XM650U

Страница 1: ...6215 Shiloh Crossing Suite G Alpharetta GA 30005 Phone 1 678 835 4934 Fax 1 678 804 1882 E Mail Support FlandersScientific com www FlandersScientific com XM Series XM650U This manual is based on beta firmware Some selections may be unavailable or not work correctly ...

Страница 2: ... 2018 Flanders Scientific Inc 2 Return to Table of Contents Contents TOPIC PAGE S Safety Precautions 3 5 Parts Their Functions 6 7 Menu 8 14 Dimensional Drawing 15 ...

Страница 3: ...enu or scopes may cause permanent BURN IN on the display s OLED panel Length of time required for burn in to develop varies due to many factors including content and luminance level You should avoid displaying static content especially in HDR mode for extended periods of time To lessen the potential severity of burn in the display will start to dim if a static image is detected for 2 or more minut...

Страница 4: ...attempt to service the product yourself Removing covers can expose you to high voltage and other unsafe conditions Please seek the assistance of a qualified service professional for all service needs If any of the following occur unplug the power cord from the AC outlet and consult a qualified service professional to perform repairs Power cord or plug becomes damaged When any liquid is spilled on ...

Страница 5: ...us obstruction of ventilation areas If using in enclosed space make sure to provide proper ventilation to maintain allowable operating temperature range The panel used in this product contains glass and can cause serious injury if broken If the unit is dropped or otherwise damaged take care to avoid possible injury by glass shards Avoid prolonged exposure to direct sunlight as this can cause damag...

Страница 6: ...ed to toggle and navigate On Screen Menu UP Used to navigate On Screen Menu DOWN Used to navigate On Screen Menu RIGHT ENTER Used to navigate On Screen Menu and to confirm selections within the On Screen Menu PHASE H POS Reserved for future use CHROMA V POS Used to adjust chroma higher or lower Pressing down on the center of this button will return the chroma setting to its default position BRIGHT...

Страница 7: ...sed output Follows Mode Selection DP In Display Port Input Audio In Out Analog Stereo Mini phono Au dio Input Output Unbalanced Audio Out delayed by exact amount of monitor video procesisng time to maintain sync USB Type A USB power can be used to power MediaLight Bias Lights RS 485 RS 485 Ports In Out for looping remote control interface LAN IP Control via select programs Back Panel ...

Страница 8: ...not fully display These menus will scroll Use the Up and Down keys to scroll up and down a menu Function Menu Function F1 Luminance Scope Scope F2 Vector Scope Video F3 Marker 1 Color F4 Marker 2 System F5 Marker 3 OSD The Function Menu allows you to assign user selectable functions to any of the 5 function buttons F1 F2 F3 F4 and F5 on the monitor keypad To assign a function to a function key hig...

Страница 9: ... to be displayed Area Marker Use the Area Marker function to select what type of marker is displayed when the marker function is active The marker selections available from this option include most commonly used markers and more complex user designed custom markers Safety Marker Use the Safety Marker function to toggle the size in percentage of the safety marker displayed This option can be used b...

Страница 10: ...ections Available MODE options AUTO attempts to automatically identify signal type particularly useful if simply switching between single link 1 5Gbps 3Gbps 6Gbps and 12Gbps SDI signals formats 6G_IN single link 6Gbps SDI input single link 6Gbps SDI output 6G_IN HD_OUT single link 6Gbps SDI input 1 5Gbps HD output 6G_DL_IN dual link 6Gbps SDI input dual link 6Gbps SDI output 6G_DL_IN 3G_OUT dual l...

Страница 11: ...oint using 12bit values in the Flanders lut format and all 3D LUTs are 17x17x17 cube format using only the header LUT_3D_SIZE 17 The DIT LUT positions should be used for technical transforms or look LUTs calibration LUTs should normally only be stored in the Calibration LUT positions In Advanced Mode 3 LUT positions are accessible as follows Front Calibration 1D LUT Calibration 3D LUT Post Calibra...

Страница 12: ... P3 white balance but 6500K may be manually selected to yield a P3 gamut with D65 white point Gamma The gamma setting allows you to set the desired gamma response EOTF Red Green Blue Gain and Bias settings White balance may be adjusted customized from one of the Temperature selection presets using the custom Red Green Blue Gain and Bias settings Factory Alignment Reset This setting deletes the Fac...

Страница 13: ...static high contrast content for extended periods of time Select On Panel will display black and remain on for approximately 8 minutes After 8 minutes the monitor will automatically shut down After unit shuts down please leave the monitor turned Off for 1 hour After 1 hour press the power button to turn the monitor back on The display will remain black for 15 seconds after boot up then a white lin...

Страница 14: ...f Contents Menu OSD Menu OSD Menu Function Time Code Off Scope Menu Position Top Left Video Color System OSD Time Code Allows you to select whether to display Time Code on screen pulled from an SDI signal Menu Position Changes position of onscreen menu ...

Страница 15: ... 2018 Flanders Scientific Inc 15 Return to Table of Contents Dimensional Drawing Large Dimensional Drawing PDF available online http www flandersscientific com uploads XM650Udim pdf ...