Menu - Color Menu
Color Menu
Function
ColorSystem
User
Scope
LUT Mode
Normal
Video
Gamut
User1
Color
Luminance
100
System
Range
SMPTE Full 4-1019
OSD
HDR
Off
ColorSystem
User - Default selection where factory calibration LUTs are stored.
CineColor - Reserved for future Use.
LightSpace / CalMAN - Open for use with LightSpace and CalMAN.
LUT Mode
Does not apply to CINECOLOR Color System.
In USER, LightSpace, or CalMAN modes select Normal or Advanced.
In Normal Mode 6 LUT positions are accessible as follows:
Front DIT 1D LUT -> DIT 3D LUT -> Post DIT 1D LUT-> Front Calibration 1D LUT -> Calibration 3D LUT
-> Post Calibration 1D LUT
In Normal Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and all
3D LUTs are 17x17x17.cube format using only the header LUT_3D_SIZE 17.
The DIT LUT positions should be used for technical transforms or look LUTs, calibration LUTs should
normally only be stored in the Calibration LUT positions.
In Advanced Mode 3 LUT positions are accessible as follows:
Front Calibration 1D LUT -> Calibration 3D LUT -> Post Calibration 1D LUT
In Advanced Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and
the 3D LUT is 33x33x33.cube format using only the header LUT_3D_SIZE 33.
LUTs can be saved to the display using the IP Remote Utility.
Application Note: LUTs are applied within the range active on the monitor’s color menu.
Gamut
Select from available options to instantly change the active color space.
Luminance