X100
FIL
TER
VESSEL
➔
➔
INSTALLATION
The height of the support legs
can be adjusted by moving the
belly bands of the leg assembly
up or down the filter housing.
Maximum floor to filter outlet
is 13 1/4 inches.
Use commercially available
3/8 inch diameter floor anchors.
5. Piping.
The piping material used
should be the same as the
base material of the vessel.
The piping temperature and
pressure rating should be
equal to or greater than that
of the vessel.
RELIEF VALVE
It is the responsibility of the
end user to protect the
system components, such as
the FSI filter, from being
over-pressurized. This can be
achieved by installing a system
relief valve.
➔
4. Mounting Location.
Locate the filter away
from direct sunlight and all
heat sources that could
elevate its temperature
beyond the maximum allow-
able. See lid for maximum
temperature rating.
MOUNTING
Hard pipe the filter housing
in place with 2 inch sch. 80
plastic piping. Secure the inlet
and outlet pipe to provide
filter support. If it is desirable
to support the filter and its
contents, polypropylene legs
and floor mounting pads are a
standard option. The legs can
be shortened by saw cutting.
Note: The plastic legs are used
in conjunction with hard
piping to provide rigid filter
support. For filters requiring
solid floor mounting, stainless
steel or carbon steel support
legs are a standard option.