GT7- 2K / 4K / 8K / 9K / 16K 

Ultraviolet System Manual 

 
 
 

Contents 

Technical Overview ...................................................................................................................................... 2

 

I. Important Notes ..................................................................................................................................... 2

 

II. Specifications ........................................................................................................................................ 2

 

III. WARNING............................................................................................................................................ 2

 

IV. Before you Purchase/Open .................................................................................................................. 2

 

V. Space Requirements ............................................................................................................................ 3

 

VI. What is Ultraviolet Sanitation ............................................................................................................... 3

 

VII. Example Applications ......................................................................................................................... 3

 

Installation Introduction ................................................................................................................................. 4

 

I. Site Preparation ..................................................................................................................................... 4

 

II. Mounting ............................................................................................................................................... 4

 

III. Installing Connections .......................................................................................................................... 4

 

IV. Thermal Relief Valve ........................................................................................................................... 4

 

V. Filter Protection .................................................................................................................................... 4

 

Commissioning & Start-up ............................................................................................................................ 4

 

I. Quartz Thimble Installation ..................................................................................................................... 4

 

II. Ballast Operation .................................................................................................................................. 5

 

III. Installing the UV Lamp ......................................................................................................................... 5

 

Maintenance ................................................................................................................................................. 6

 

I. Replacement Parts................................................................................................................................. 6

 

Troubleshooting ............................................................................................................................................ 7

 

 
 
 
 
 
 
 
 
 

 

Содержание GT7-16K

Страница 1: ...ements 3 VI What is Ultraviolet Sanitation 3 VII Example Applications 3 Installation Introduction 4 I Site Preparation 4 II Mounting 4 III Installing Connections 4 IV Thermal Relief Valve 4 V Filter P...

Страница 2: ...must be followed closely to prevent serious personal injury Ensure eye protection is worn when servicing and installing this unit to protect from harmful UV C Radiation This radiation can be harmful...

Страница 3: ...ounding plumbing must be earthed to prevent electrolysis which will cause corrosion VI What is Ultraviolet Sanitation Ultraviolet sanitation works by breaking down the cell wall of a micro organism al...

Страница 4: ...to install a TRV to limit the temperature When installing a TRV note the below requirements The TRV must be installed on the Outlet of the UV System which should be the open end The TRV tube must be a...

Страница 5: ...ure indicator light along with an audible alarm should there be a fault The ballast will automatically reset when turned on off GT7 16K PS In order to guarantee user safety this ballast features compl...

Страница 6: ...as waterproof 6 Connect the earth wire to the lug on the bottom of the UV chamber as shown above 7 Plug the ballast into a certified single socket surge protector then into a 240V 10A GPO 8 Turn on t...

Страница 7: ...PS 10W 40W AU Certified RCM Ballast to Suit 4 Pin Lamps GT7 16K PS 33W 120W AU Certified RCM Ballast to Suit 4 Pin Lamps Mounting Clamps GT11 8G 1 PC Plastic Mounting Clamp Suitable for U Sink Instal...

Страница 8: ...check for Water ingress from either rain or leaks or any signs of moisture or condensation in around the electricals Due to the elevated temperature of the lamp high humidity may cause condensate to f...

Страница 9: ...ff check connections and turn back on to see if it fixes the alarm 2 The ballast could have a problem with the lamp failure protection and may require replacement Turn the system off check connections...

Страница 10: ...buyer is responsible for keeping record and proof of installation in the form of an invoice and or receipt UV Systems must be connected to a surge protector Directly before being connected to 240V so...

Страница 11: ...of invoice Power Supply 1 Year GT7 8K GT7 9K GT7 16K Stainless Steel UV Reactor Chamber 10 Years Quartz Thimble 1 Year Pro Rata from date of invoice UV Lamp 1 Year Pro Rata from date of invoice Power...

Отзывы: